Volumn 8, Issue 2, 2012, Pages 196-204

Longitudinal stent deformation: Insights on mechanisms, treatments and outcomes from the Food and Drug Administration Manufacturer and User Facility Device Experience database

Author keywords

FDA MAUDE database; Longitudinal stent deformation; PCI complications; Stent platforms

Indexed keywords

ADVERSE OUTCOME; ARTICLE; CLINICAL ARTICLE; CORONARY ARTERY BYPASS GRAFT; CORONARY STENT; DISEASE PREDISPOSITION; EMERGENCY SURGERY; FACTUAL DATABASE; HUMAN; IATROGENIC DISEASE; LONGITUDINAL STENT DEFORMATION; OUTCOME ASSESSMENT; PATHOGENESIS; PATHOLOGICAL ANATOMY; STENT THROMBOSIS;

EID: 84865611916     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV8I2A33     Document Type: Article
Times cited : (70)

References (13)
  • 1
    • 80155191184 scopus 로고    scopus 로고
    • Stent design back in the picture: An engineering perspective on longitudinal stent compression
    • Mortier P, De Beule M. Stent design back in the picture: an engineering perspective on longitudinal stent compression. EuroIntervention. 2011;7:773-5.
    • (2011) EuroIntervention , vol.7 , pp. 773-775
    • Mortier, P.1    De Beule, M.2
  • 2
    • 84858755999 scopus 로고    scopus 로고
    • Engineering assessment of the longitudinal compression behaviour of contemporary coronary stents
    • Nov 7. [Epub ahead of print]
    • Prabhu S, Schikorr T, Mahmoud T, Jacobs J, Potgieter A, Simonton C. Engineering assessment of the longitudinal compression behaviour of contemporary coronary stents. EuroIntervention. 2011 Nov 7. [Epub ahead of print].
    • (2011) EuroIntervention
    • Prabhu, S.1    Schikorr, T.2    Mahmoud, T.3    Jacobs, J.4    Potgieter, A.5    Simonton, C.6
  • 3
    • 80155191186 scopus 로고    scopus 로고
    • Longitudinal compression: A "new" complication with modern coronary stent platfroms - Time to think beyond deliverability?
    • Hanratty CG, Walsh SJ. Longitudinal compression: a "new" complication with modern coronary stent platfroms - time to think beyond deliverability? EuroIntervention. 2011;7:872-877.
    • (2011) EuroIntervention , vol.7 , pp. 872-877
    • Hanratty, C.G.1    Walsh, S.J.2
  • 5
    • 83955165359 scopus 로고    scopus 로고
    • Deformation, Longitudinal Shortening, and Accordion of an Ion Stent
    • Robinson AD, Schreiber TL, Grines CL. Deformation, Longitudinal Shortening, and Accordion of an Ion Stent. J Interv Cardiol. 2011;24:493-5.
    • (2011) J Interv Cardiol , vol.24 , pp. 493-495
    • Robinson, A.D.1    Schreiber, T.L.2    Grines, C.L.3
  • 6
    • 84355162723 scopus 로고    scopus 로고
    • Stent Longitudinal Integrity. Bench Insights into a Clinical Problem
    • Ormiston JA, Webber B, Webster MW. Stent Longitudinal Integrity. Bench Insights Into a Clinical Problem. JACC Cardiovasc Interv. 2011;4:1310-1317.
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 1310-1317
    • Ormiston, J.A.1    Webber, B.2    Webster, M.W.3
  • 7
    • 85017370740 scopus 로고    scopus 로고
    • Platinum Chromium Stent Series™ the TAXUS™ Element™ (ION™), PROMUS Element™ and OMEGA™ Stents
    • Allocco DJ, Jacoski MV, Huibregtse B, Mickley T, Dawkins KD. Platinum Chromium Stent Series™ The TAXUS™ Element™ (ION™), PROMUS Element™ and OMEGA™ Stents. J Interv Cardiol. 2011;6:134-141.
    • (2011) J Interv Cardiol , vol.6 , pp. 134-141
    • Allocco, D.J.1    Jacoski, M.V.2    Huibregtse, B.3    Mickley, T.4    Dawkins, K.D.5
  • 8
    • 79954416871 scopus 로고    scopus 로고
    • A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: The PLATINUM (a Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System [PROMUS Element] for the Treatment of Up to Two de Novo Coronary Artery Lesions) trial
    • Stone GW, Teirstein PS, Meredith IT, Farah B, Dubois CL, Feldman RL, Dens J, Hagiwara N, Allocco DJ, Dawkins KD. A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: the PLATINUM (a Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System [PROMUS Element] for the Treatment of Up to Two de Novo Coronary Artery Lesions) trial. J Am Coll Cardiol. 2011;57: 1700-8.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1700-1708
    • Stone, G.W.1    Teirstein, P.S.2    Meredith, I.T.3    Farah, B.4    Dubois, C.L.5    Feldman, R.L.6    Dens, J.7    Hagiwara, N.8    Allocco, D.J.9    Dawkins, K.D.10
  • 9
    • 77955661056 scopus 로고    scopus 로고
    • Clinical and angiographic outcomes after treatment of de novo coronary stenoses with a novel platinum chromium thin-strut stent: Primary results of the PERSEUS (Prospective Evaluation in a Randomized Trial of the Safety and Efficacy of the Use of the TAXUS Element Paclitaxel-Eluting Coronary Stent System) trial
    • Kereiakes DJ, Cannon LA, Feldman RL, Popma JJ, Magorien R, Whitbourn R, Dauber IM, Rabinowitz AC, Ball MW, Bertolet B, Kabour A, Foster MC, Wang JC, Underwood P, Dawkins KD. Clinical and angiographic outcomes after treatment of de novo coronary stenoses with a novel platinum chromium thin-strut stent: primary results of the PERSEUS (Prospective Evaluation in a Randomized Trial of the Safety and Efficacy of the Use of the TAXUS Element Paclitaxel-Eluting Coronary Stent System) trial. J Am Coll Cardiol. 2010;56:264-71.
    • (2010) J Am Coll Cardiol , vol.56 , pp. 264-271
    • Kereiakes, D.J.1    Cannon, L.A.2    Feldman, R.L.3    Popma, J.J.4    Magorien, R.5    Whitbourn, R.6    Dauber, I.M.7    Rabinowitz, A.C.8    Ball, M.W.9    Bertolet, B.10    Kabour, A.11    Foster, M.C.12    Wang, J.C.13    Underwood, P.14    Dawkins, K.D.15
  • 11
    • 80051715276 scopus 로고    scopus 로고
    • PLATINUM QCA: A prospective, multicentre study assessing clinical, angiographic, and intravascular ultrasound outcomes with the novel platinum chromium thin-strut PROMUS Element everolimus-eluting stent in de novo coronary stenoses
    • Meredith IT, Whitbourn R, Scott D, El-Jack S, Zambahari R, Stone GW, Teirstein PS, Starzyk RM, Allocco DJ, Dawkins KD. PLATINUM QCA: a prospective, multicentre study assessing clinical, angiographic, and intravascular ultrasound outcomes with the novel platinum chromium thin-strut PROMUS Element everolimus-eluting stent in de novo coronary stenoses. EuroIntervention. 2011;7:84-90.
    • (2011) EuroIntervention , vol.7 , pp. 84-90
    • Meredith, I.T.1    Whitbourn, R.2    Scott, D.3    El-Jack, S.4    Zambahari, R.5    Stone, G.W.6    Teirstein, P.S.7    Starzyk, R.M.8    Allocco, D.J.9    Dawkins, K.D.10
  • 12
    • 77249108463 scopus 로고    scopus 로고
    • A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program
    • Allocco DJ, Cannon LA, Britt A, Heil JE, Nersesov A, Wehrenberg S, Dawkins KD, Kereiakes DJ. A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: design and statistical methods of the PERSEUS clinical program. Trials. 2010;11:1.
    • (2010) Trials , vol.11 , pp. 1
    • Allocco, D.J.1    Cannon, L.A.2    Britt, A.3    Heil, J.E.4    Nersesov, A.5    Wehrenberg, S.6    Dawkins, K.D.7    Kereiakes, D.J.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.