Volumn 199, Issue 3, 2012, Pages 588-594

Comparisons of image quality and radiation dose between iterative reconstruction and filtered back projection reconstruction algorithms in 256-MDCT coronary angiography

Author keywords

Coronary angiography; CT; Filtered back projection; Image quality; Iterative reconstruction; Radiation dose

Indexed keywords

ADULT; AGED; ALGORITHM; ANGIOCARDIOGRAPHY; AREA UNDER THE CURVE; ARTICLE; BODY MASS; CONTRAST; CONTROLLED STUDY; DOSIMETRY; ELECTROCARDIOGRAM; FEMALE; HEART RATE; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; RADIATION DOSE; RECEIVER OPERATING CHARACTERISTIC;

EID: 84865607400     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.11.7557     Document Type: Article
Times cited : (89)

References (36)
  • 7
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    • DOI 10.1016/j.jacc.2005.05.056, PII S0735109705013148
    • Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005; 46:552-557 (Pubitemid 41040301)
    • (2005) Journal of the American College of Cardiology , vol.46 , Issue.3 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3    Goldstein, J.A.4
  • 9
    • 67849114628 scopus 로고    scopus 로고
    • Maximizing dose reductions with cardiac CT
    • Budoff MJ. Maximizing dose reductions with cardiac CT. Int J Cardiovasc Imaging 2009; 25(suppl 2): 279-287
    • (2009) Int J Cardiovasc Imaging , vol.25 , Issue.SUPPL. 2 , pp. 279-287
    • Budoff, M.J.1
  • 10
    • 33645749654 scopus 로고    scopus 로고
    • Radiation dose estimates from cardiac multislice computed tomography in daily practice: Impact of different scanning protocols on effective dose estimates
    • DOI 10.1161/CIRCULATIONAHA.105.602490, PII 0000301720060314000008
    • Hausleiter J, Meyer T, Hadamitzky M, et al. Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates. Circulation 2006; 113:1305-1310 (Pubitemid 43739452)
    • (2006) Circulation , vol.113 , Issue.10 , pp. 1305-1310
    • Hausleiter, J.1    Meyer, T.2    Hadamitzky, M.3    Huber, E.4    Zankl, M.5    Martinoff, S.6    Kastrati, A.7    Schomig, A.8
  • 12
    • 78650993428 scopus 로고    scopus 로고
    • Radiation dose from coronary CT angiography: Five years of progress
    • Raff GL. Radiation dose from coronary CT angiography: five years of progress. J Cardiovasc Comput Tomogr 2010; 4:365-374
    • (2010) J Cardiovasc Comput Tomogr , vol.4 , pp. 365-374
    • Raff, G.L.1
  • 13
    • 51549106753 scopus 로고    scopus 로고
    • Optimal electrocardiographic pulsing windows and heart rate: Effect on image quality and radiation exposure at dual-source coronary CT angiography
    • Weustink AC, Mollet NR, Pugliese F, et al. Optimal electrocardiographic pulsing windows and heart rate: effect on image quality and radiation exposure at dual-source coronary CT angiography. Radiology 2008; 248:792-798
    • (2008) Radiology , vol.248 , pp. 792-798
    • Weustink, A.C.1    Mollet, N.R.2    Pugliese, F.3
  • 14
    • 49049120370 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: Assessment of image quality, stenosis, and radiation dose
    • Hirai N, Horiguchi J, Fujioka C, et al. Prospective versus retrospective ECG-gated 64-detector coronary CT angiography: assessment of image quality, stenosis, and radiation dose. Radiology 2008; 248:424-430
    • (2008) Radiology , vol.248 , pp. 424-430
    • Hirai, N.1    Horiguchi, J.2    Fujioka, C.3
  • 15
    • 67849097507 scopus 로고    scopus 로고
    • Prospective ECG-triggered sequential scan protocol for coronary dual-source CT angiography: Initial experience
    • Hein F, Meyer T, Hadamitzky M, et al. Prospective ECG-triggered sequential scan protocol for coronary dual-source CT angiography: initial experience. Int J Cardiovasc Imaging 2009; 25(suppl 2):231-239
    • (2009) Int J Cardiovasc Imaging , vol.25 , Issue.SUPPL. 2 , pp. 231-239
    • Hein, F.1    Meyer, T.2    Hadamitzky, M.3
  • 16
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: Improved image quality and reduced radiation dose
    • Earls JP, Berman E, Urban BA, et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 2008; 246:742-753
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.2    Urban, B.A.3
  • 17
    • 38349134611 scopus 로고    scopus 로고
    • Feasibility of low-dose coronary CT angiography: First experience with prospective ECG-gating
    • Husmann L, Valenta I, Gaemperli O, et al. Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating. Eur Heart J 2008; 29:191-197
    • (2008) Eur Heart J , vol.29 , pp. 191-197
    • Husmann, L.1    Valenta, I.2    Gaemperli, O.3
  • 18
    • 49049116757 scopus 로고    scopus 로고
    • Prospective verse retrospective ECG gating for 64-detector CT of the coronary arteries: Comparison of image quality and patient radiation dose
    • Shuman WP, Branch KR, May JM, et al. Prospective verse retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose. Radiology 2008; 248:431-437
    • (2008) Radiology , vol.248 , pp. 431-437
    • Shuman, W.P.1    Branch, K.R.2    May, J.M.3
  • 19
    • 84861232279 scopus 로고    scopus 로고
    • Prospectively versus retrospectively ECG-gated 256-slice coronary CT angiography: Image quality and radiation dose over expanded heart rates
    • Hou Y, Yue Y, Guo W, et al. Prospectively versus retrospectively ECG-gated 256-slice coronary CT angiography: image quality and radiation dose over expanded heart rates. Int J Cardiovasc Imaging 2012; 28:153-162
    • (2012) Int J Cardiovasc Imaging , vol.28 , pp. 153-162
    • Hou, Y.1    Yue, Y.2    Guo, W.3
  • 20
    • 62649158904 scopus 로고    scopus 로고
    • Prospectively gated axial CT coronary angiography: Preliminary experiences with a novel low-dose technique
    • Klass O, Jeltsch M, Feuerlein S, et al. Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique. Eur Radiol 2009; 19:829-836
    • (2009) Eur Radiol , vol.19 , pp. 829-836
    • Klass, O.1    Jeltsch, M.2    Feuerlein, S.3
  • 21
    • 0037448795 scopus 로고    scopus 로고
    • Radiation dose in computed tomography of the heart
    • DOI 10.1161/01.CIR.0000048965.56529.C2
    • Morin RL, Gerber TC, McCollough CH. Radiation dose in computed tomography of the heart. Circulation 2003; 107:917-922 (Pubitemid 36241053)
    • (2003) Circulation , vol.107 , Issue.6 , pp. 917-922
    • Morin, R.L.1    Gerber, T.C.2    McCollough, C.H.3
  • 23
    • 68549088465 scopus 로고    scopus 로고
    • Impact of a reduced tube voltage on CT angiography and radiation dose: Results of the PROTECTION I study
    • Bischoff B, Hein F, Meyer T, et al. Impact of a reduced tube voltage on CT angiography and radiation dose: results of the PROTECTION I study. JACC Cardiovasc Imaging 2009; 2:940-946
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 940-946
    • Bischoff, B.1    Hein, F.2    Meyer, T.3
  • 26
    • 77949865226 scopus 로고    scopus 로고
    • Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique
    • Prakash P, Kalra MK, Kambadakone AK, et al. Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol 2010; 45:202-210
    • (2010) Invest Radiol , vol.45 , pp. 202-210
    • Prakash, P.1    Kalra, M.K.2    Kambadakone, A.K.3
  • 27
    • 75349092506 scopus 로고    scopus 로고
    • Low tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - Initial clinical experience
    • Marin D, Nelson RC, Schindera ST, et al. Low tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - initial clinical experience. Radiology 2010; 254:145-153
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 28
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
    • Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR 2009; 193:764-771
    • (2009) AJR , vol.193 , pp. 764-771
    • Hara, A.K.1    Paden, R.G.2    Silva, A.C.3    Kujak, J.L.4    Lawder, H.J.5    Pavlicek, W.6
  • 29
    • 79751526184 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examination in 80 patients
    • Pontana F, Duhamel A, Pagniez J, et al. Chest computed tomography using iterative reconstruction vs filtered back projection. Part 2. Image quality of low-dose CT examination in 80 patients. Eur Radiol 2011; 21:636-643
    • (2011) Eur Radiol , vol.21 , pp. 636-643
    • Pontana, F.1    Duhamel, A.2    Pagniez, J.3
  • 30
    • 77956832667 scopus 로고    scopus 로고
    • Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: The ERASIR study
    • Leipsic J, LaBounty TM, Heilbron B, et al. Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. AJR 2010; 195:655-660
    • (2010) AJR , vol.195 , pp. 655-660
    • Leipsic, J.1    LaBounty, T.M.2    Heilbron, B.3
  • 31
    • 80054984676 scopus 로고    scopus 로고
    • Iterative reconstruction in image space (IRIS) in cardiac computed tomography: Initial experience
    • Bittencourt MS, Schmidt B, Seltmann M, et al. Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience. Int J Cardiovasc Imaging 2011; 27:1081-1087
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 1081-1087
    • Bittencourt, M.S.1    Schmidt, B.2    Seltmann, M.3
  • 32
    • 0347625749 scopus 로고    scopus 로고
    • Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction
    • DOI 10.1118/1.1624756
    • Manzke R, Grass M, Nielsen T, Shechter G, Hawkes D. Adaptive temporal resolution optimization in helical cardiac cone beam reconstruction. Med Phys 2003; 30:3072-3080 (Pubitemid 37553747)
    • (2003) Medical Physics , vol.30 , Issue.12 , pp. 3072-3080
    • Manzke, R.1    Grass, M.2    Nielsen, T.3    Shechter, G.4    Hawkes, D.5
  • 34
    • 80054966383 scopus 로고    scopus 로고
    • 320-Row CT coronary angiography: Effect of 100- kV tube voltages on image quality, contrast volume, and radiation dose
    • Zhang C, Zhang Z, Yan Z, Xu L, Yu W, Wang R. 320-row CT coronary angiography: effect of 100- kV tube voltages on image quality, contrast volume, and radiation dose. Int J Cardiovasc Imaging 2011; 27:1059-1068
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 1059-1068
    • Zhang, C.1    Zhang, Z.2    Yan, Z.3    Xu, L.4    Yu, W.5    Wang, R.6
  • 36
    • 77958569748 scopus 로고    scopus 로고
    • Abdominal CT: Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques
    • Singh S, Kalra MK, Hsieh J, et al. Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology 2010; 257:373-383
    • (2010) Radiology , vol.257 , pp. 373-383
    • Singh, S.1    Kalra, M.K.2    Hsieh, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.