메뉴 건너뛰기




Volumn 86, Issue 9, 2012, Pages 2397-2404

A comprehensive method for estimating energy losses due to shading of GC-BIPV systems using monitoring data

Author keywords

Energy losses; Grid connected building integrated PV systems; Monitoring data; Partial shading; Shading factor

Indexed keywords

BUILDING INTEGRATED PHOTOVOLTAIC; COMPREHENSIVE METHOD; GRID-CONNECTED; LOSS OF ENERGY; MAXIMUM OUTPUT; PARTIAL SHADING; PV SYSTEM; SHADING FACTOR;

EID: 84865578633     PISSN: 0038092X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solener.2012.05.008     Document Type: Article
Times cited : (35)

References (17)
  • 1
    • 0011191898 scopus 로고
    • Analytical expressions for the determination of the maximum power point and the fill factor of a solar cell
    • Araujo G.L., Nchez E.S. Analytical expressions for the determination of the maximum power point and the fill factor of a solar cell. Solar Cells 1982, 5:377-386.
    • (1982) Solar Cells , vol.5 , pp. 377-386
    • Araujo, G.L.1    Nchez, E.S.2
  • 2
    • 79957847253 scopus 로고    scopus 로고
    • Self-shading losses of fixed free-standing PV arrays
    • Brecl K., Topi M. Self-shading losses of fixed free-standing PV arrays. Renewable Energy 2011, 36:3211-3216.
    • (2011) Renewable Energy , vol.36 , pp. 3211-3216
    • Brecl, K.1    Topi, M.2
  • 3
    • 42149165484 scopus 로고    scopus 로고
    • A new estimation method of irradiance on a partially shaded PV generator in grid-connected photovoltaic systems
    • Drif M., Pérez P.J., Aguilera J., Aguilar J.D. A new estimation method of irradiance on a partially shaded PV generator in grid-connected photovoltaic systems. Renewable Energy 2008, 33:2048-2056.
    • (2008) Renewable Energy , vol.33 , pp. 2048-2056
    • Drif, M.1    Pérez, P.J.2    Aguilera, J.3    Aguilar, J.D.4
  • 7
    • 0011384098 scopus 로고
    • Daily insolation on surfaces tilted towards the equator
    • Liu B.Y.H., Jordan R.C. Daily insolation on surfaces tilted towards the equator. Transactions of ASHRAE 1962, 67:526-541.
    • (1962) Transactions of ASHRAE , vol.67 , pp. 526-541
    • Liu, B.Y.H.1    Jordan, R.C.2
  • 9
    • 0035546673 scopus 로고    scopus 로고
    • Calculation of the PV modules angular losses under field conditions by means of an analytical model
    • Martin N., Ruiz J.M. Calculation of the PV modules angular losses under field conditions by means of an analytical model. Solar Energy Materials & Solar Cells 2001, 70:25-38.
    • (2001) Solar Energy Materials & Solar Cells , vol.70 , pp. 25-38
    • Martin, N.1    Ruiz, J.M.2
  • 11
    • 77949876934 scopus 로고    scopus 로고
    • A 24-hours forecast of solar irradiance using artificial neural network: application for performance prediction of a grid-connected PV plant at Trieste, Italy
    • Mellit A., Massi Pavan.A. A 24-hours forecast of solar irradiance using artificial neural network: application for performance prediction of a grid-connected PV plant at Trieste, Italy. Solar Energy 2010, 84:807-821.
    • (2010) Solar Energy , vol.84 , pp. 807-821
    • Mellit, A.1    Massi, P.2
  • 12
    • 0023273211 scopus 로고
    • A new simplified version of the perez irradiance model for tilted surfaces
    • Perez R., Seals R., Ineichen P., Stewart R., Menicucci D. A new simplified version of the perez irradiance model for tilted surfaces. Solar Energy 1987, 39:221-231.
    • (1987) Solar Energy , vol.39 , pp. 221-231
    • Perez, R.1    Seals, R.2    Ineichen, P.3    Stewart, R.4    Menicucci, D.5
  • 13
    • 84865577972 scopus 로고    scopus 로고
    • One-site visits site survey and shading analysis
    • In: Chapter of Planning and Installing Photovoltaic Systems. J&J.
    • Quashning, V., 2005. One-site visits site survey and shading analysis. In: Chapter of Planning and Installing Photovoltaic Systems. J&J.
    • (2005)
    • Quashning, V.1
  • 15
    • 80055055606 scopus 로고    scopus 로고
    • Optimum design of shading-type building-integrated photovoltaic claddings with different surface azimuth angles
    • Sun L., Lu L., Yang H. Optimum design of shading-type building-integrated photovoltaic claddings with different surface azimuth angles. Applied Energy 2012, 90:233-240.
    • (2012) Applied Energy , vol.90 , pp. 233-240
    • Sun, L.1    Lu, L.2    Yang, H.3
  • 17
    • 0035284137 scopus 로고    scopus 로고
    • Evaluation of effective shading factor by fitting a clear-day pattern obtained from hourly maximum irradiance data
    • Uchida D., Otani K., Kurokawa K. Evaluation of effective shading factor by fitting a clear-day pattern obtained from hourly maximum irradiance data. Solar Energy Materials & Solar Cells 2001, 67:519-528.
    • (2001) Solar Energy Materials & Solar Cells , vol.67 , pp. 519-528
    • Uchida, D.1    Otani, K.2    Kurokawa, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.