Volumn 45, Issue 1, 2012, Pages 107-116

Integration and optimization study on the coal-fired power plant with CO2 capture using MEA

Author keywords

Efficiency penalties; Heat integration; MEA

Indexed keywords

COAL; COAL FUELED FURNACES; COMPUTER SOFTWARE; ENERGY UTILIZATION; FOSSIL FUEL POWER PLANTS; HEAT PUMP SYSTEMS; HIERARCHICAL SYSTEMS; INTEGRATION; STEAM ENGINEERING; STEAM POWER PLANTS; STEAM TURBINES; WASTE HEAT; WATER HEATERS;

EID: 84865440297     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.energy.2011.12.014     Document Type: Article
Times cited : (121)

References (22)
  • 1
    • 84865437014 scopus 로고    scopus 로고
    • Energy Information Administration. International energy outlook. DOE/EIA-0484,
    • Energy Information Administration. International energy outlook. DOE/EIA-0484, 2009.
    • (2009)
  • 2
    • 79958123878 scopus 로고    scopus 로고
    • The energy situation and its sustainable development strategy in China
    • Zhang Na, Lior Noam, Jin Hongguang The energy situation and its sustainable development strategy in China. Energy 2011, 36:3639-3649.
    • (2011) Energy , vol.36 , pp. 3639-3649
    • Zhang, N.1    Lior, N.2    Jin, H.3
  • 3
    • 77958152233 scopus 로고    scopus 로고
    • Power generation from pulverized coal in China
    • Yang Yongping, Guo Xiyan, Wang Ningling Power generation from pulverized coal in China. Energy 2010, 35:4336-4348.
    • (2010) Energy , vol.35 , pp. 4336-4348
    • Yang, Y.1    Guo, X.2    Wang, N.3
  • 6
    • 85017999446 scopus 로고    scopus 로고
    • Massood Ramezan, Timothy J Skone, Nsakala ya Nsakala, Gregory N Liljedahl. Carbon dioxide capture from existing coal-fired power plants.DOE/NETL-401/110907.
    • Massood Ramezan, Timothy J Skone, Nsakala ya Nsakala, Gregory N Liljedahl. Carbon dioxide capture from existing coal-fired power plants.DOE/NETL-401/110907.
  • 7
    • 78650730322 scopus 로고    scopus 로고
    • Development of an economic post-combustion carbon capture process
    • Jockenhoevel Tobias, Schneider Ruediger, Rode Helmut Development of an economic post-combustion carbon capture process. Energy Procedia 2009, 1043-1050.
    • (2009) Energy Procedia , pp. 1043-1050
    • Jockenhoevel, T.1    Schneider, R.2    Rode, H.3
  • 9
    • 0037108565 scopus 로고    scopus 로고
    • 2 capture technology for power plant greenhouse gas control
    • 2 capture technology for power plant greenhouse gas control. Environmental Science Technology 2002, 4467-4475.
    • (2002) Environmental Science Technology , pp. 4467-4475
    • Rao, A.1    Rubin, E.2
  • 10
  • 13
    • 34250789296 scopus 로고    scopus 로고
    • 2 capture unit single- and blended-amines into supercritical coalfired power plant: implications for emission and energy management
    • 2 capture unit single- and blended-amines into supercritical coalfired power plant: implications for emission and energy management. International Journal of Greenhouse Gas Control 2007, 1:143-150.
    • (2007) International Journal of Greenhouse Gas Control , vol.1 , pp. 143-150
    • Aroonwilas, A.1    Veawab, A.2
  • 15
    • 34547749868 scopus 로고    scopus 로고
    • Initial evaluation of the impact of post-combustion capture of carbon dioxide on supercritical pulverised coal power plant part load performance
    • Chalmers H., Gibbins J. Initial evaluation of the impact of post-combustion capture of carbon dioxide on supercritical pulverised coal power plant part load performance. Fuel 2007, 86:2109-2123.
    • (2007) Fuel , vol.86 , pp. 2109-2123
    • Chalmers, H.1    Gibbins, J.2
  • 16
    • 0036603857 scopus 로고    scopus 로고
    • Saving energy in distillation towers by feed splitting
    • Soave G., Feliu J.A. Saving energy in distillation towers by feed splitting. Applied Thermal Engineering 2002, 22:889-896.
    • (2002) Applied Thermal Engineering , vol.22 , pp. 889-896
    • Soave, G.1    Feliu, J.A.2
  • 17
    • 0037962073 scopus 로고    scopus 로고
    • 2 absorption/stripping with monoethanolamine
    • 2 absorption/stripping with monoethanolamine. AIChE Journal 2003, 49(7):1676-1687.
    • (2003) AIChE Journal , vol.49 , Issue.7 , pp. 1676-1687
    • Freguia, S.1    Rochelle, G.T.2
  • 18
    • 85018007470 scopus 로고    scopus 로고
    • Simulation and optimization of a coal-fired power plant with integrated CO2 capture using MEA scrubbing. In: Eighth International Conference on Greenhouse Gas Control Technologies, Trondheim, Norway, ().
    • Ali C. Simulation and optimization of a coal-fired power plant with integrated CO2 capture using MEA scrubbing. In: Eighth International Conference on Greenhouse Gas Control Technologies, Trondheim, Norway, 2006 (). http://www.ghgt8.no.
    • (2006)
    • Ali, C.1
  • 19
    • 85018004698 scopus 로고    scopus 로고
    • Charles W White. III. ASPEN plus simulation of CO2 recovery process. Final report. DOE/NETL-2002/1182.
    • Charles W White. III. ASPEN plus simulation of CO2 recovery process. Final report. DOE/NETL-2002/1182.
  • 21
    • 0001889030 scopus 로고    scopus 로고
    • Development of energy saving technology for flue gas carbon dioxide recovery in power plant by chemical absorption method and steam system
    • Mimura T., Simayoshi H., Suda T., Iijima M., Mituoka S. Development of energy saving technology for flue gas carbon dioxide recovery in power plant by chemical absorption method and steam system. Energy Conversion and Management 1997, 38:S57-S62.
    • (1997) Energy Conversion and Management , vol.38
    • Mimura, T.1    Simayoshi, H.2    Suda, T.3    Iijima, M.4    Mituoka, S.5
  • 22
    • 0032684505 scopus 로고    scopus 로고
    • Performance modelling of a carbon dioxide removal system for power plants
    • Desideri U., Paolucci A. Performance modelling of a carbon dioxide removal system for power plants. Energy Conversion Management 1999, 40:1899-1915.
    • (1999) Energy Conversion Management , vol.40 , pp. 1899-1915
    • Desideri, U.1    Paolucci, A.2