메뉴 건너뛰기




Volumn 101, Issue 7, 2012, Pages

The quasi-stable lipid shelled microbubble in response to consecutive ultrasound pulses

Author keywords

[No Author keywords available]

Indexed keywords

CONTRAST ENHANCED ULTRASOUND; DRUG RELEASE; FRAMES PER SECONDS; LIPID SHELL; MICRO-BUBBLE; MICROBUBBLES; RESONANCE PEAK; SHELL MATERIALS; SPECTRAL SIGNATURE; ULTRA HIGH SPEED; ULTRASOUND EXPOSURE; ULTRASOUND PULSE;

EID: 84865418395     PISSN: 00036951     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.4746258     Document Type: Article
Times cited : (25)

References (25)
  • 8
    • 0038401274 scopus 로고    scopus 로고
    • On the destruction of microbubble ultrasound contrast agents
    • DOI 10.1016/S0301-5629(02)00787-1
    • E. Stride and N. Saffari, Ultrasound Med. Biol. 29, 563 (2003). 10.1016/S0301-5629(02)00787-1 (Pubitemid 36561424)
    • (2003) Ultrasound in Medicine and Biology , vol.29 , Issue.4 , pp. 563-573
    • Stride, E.1    Saffari, N.2
  • 10
    • 14744278053 scopus 로고    scopus 로고
    • High-speed optical observations of contrast agent destruction
    • DOI 10.1016/j.ultrasmedbio.2004.12.004, PII S0301562904004181
    • A. Bouakaz, M. Versluis, and N. de Jong, Ultrasound Med. Biol. 31, 391 (2005). 10.1016/j.ultrasmedbio.2004.12.004 (Pubitemid 40327228)
    • (2005) Ultrasound in Medicine and Biology , vol.31 , Issue.3 , pp. 391-399
    • Bouakaz, A.1    Versluis, M.2    De Jong, N.3
  • 11
    • 44149124040 scopus 로고    scopus 로고
    • 10.1016/j.addr.2008.03.011
    • V. Sboros, Adv. Drug Delivery Rev. 60, 1117 (2008). 10.1016/j.addr.2008. 03.011
    • (2008) Adv. Drug Delivery Rev. , vol.60 , pp. 1117
    • Sboros, V.1
  • 20
    • 40949123826 scopus 로고    scopus 로고
    • Nonspherical Vibrations of Microbubbles in Contact with a Wall-A Pilot Study at Low Mechanical Index
    • DOI 10.1016/j.ultrasmedbio.2007.10.001, PII S0301562907005078
    • H. J. Vos, B. Dollet, J. G. Bosch, M. Versluis, and N. de Jong, Ultrasound Med. Biol. 34, 685 (2008). 10.1016/j.ultrasmedbio.2007.10.001 (Pubitemid 351417686)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.4 , pp. 685-688
    • Vos, H.J.1    Dollet, B.2    Bosch, J.G.3    Versluis, M.4    De Jong, N.5
  • 22
    • 0034209729 scopus 로고    scopus 로고
    • An in vitro comparison of ultrasonic contrast agents in solutions with varying air levels
    • DOI 10.1016/S0301-5629(00)00215-5, PII S0301562900002155
    • V. Sboros, C. Moran, T. Anderson, and W. McDicken, Ultrasound Med. Biol. 26, 807 (2000). 10.1016/S0301-5629(00)00215-5 (Pubitemid 30609597)
    • (2000) Ultrasound in Medicine and Biology , vol.26 , Issue.5 , pp. 807-818
    • Sboros, V.1    Moran, C.M.2    Anderson, T.3    McDicken, W.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.