메뉴 건너뛰기




Volumn 58, Issue , 2012, Pages 278-288

Life cycle assessment approach for the optimization of sustainable building envelopes: An application on solar wall systems

Author keywords

Cumulative energy demand; Global warming potential; Level factorial plan; Life cycle assessment (LCA); Optimization analysis; Solar walls

Indexed keywords

CUMULATIVE ENERGY DEMANDS; GLOBAL WARMING POTENTIAL; LEVEL FACTORIAL PLAN; LIFE CYCLE ASSESSMENT (LCA); OPTIMIZATION ANALYSIS; SOLAR WALLS;

EID: 84865337100     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2012.08.003     Document Type: Article
Times cited : (116)

References (24)
  • 1
    • 84883272275 scopus 로고    scopus 로고
    • Directive 2010/31/EU of the European Parliament and of the Council of 19 May 2010 on the energy performance of buildings (recast)
    • Directive 2010/31/EU of the European Parliament and of the Council of 19 May 2010 on the energy performance of buildings (recast). Off J Eur Commun 2010.
    • (2010) Off J Eur Commun
  • 2
    • 67651023739 scopus 로고    scopus 로고
    • Life cycle assessment in buildings: state-of-the-art and simplified LCA methodology as a complement for building certification
    • Bribián I.Z., Usón A.A., Scarpellini S. Life cycle assessment in buildings: state-of-the-art and simplified LCA methodology as a complement for building certification. Build Environ 2009, 44:2510-2520.
    • (2009) Build Environ , vol.44 , pp. 2510-2520
    • Bribián, I.Z.1    Usón, A.A.2    Scarpellini, S.3
  • 3
    • 67651022523 scopus 로고    scopus 로고
    • Annex 31: energy related environmental impact of buildings, technical synthesis report
    • International Energy Agency.
    • Nibel S, Luetzkendorf T, Knapen M, Boonstra C, Moffat S. Annex 31: energy related environmental impact of buildings, technical synthesis report. International Energy Agency.
    • Nibel, S.1    Luetzkendorf, T.2    Knapen, M.3    Boonstra, C.4    Moffat, S.5
  • 4
    • 0038722795 scopus 로고    scopus 로고
    • Generic LCA - methodology applicable for buildings, constructions and operation services - today practice and development needs
    • Erlandsson M., Borg M. Generic LCA - methodology applicable for buildings, constructions and operation services - today practice and development needs. Build Environ July 2003, 38(7):919-938.
    • (2003) Build Environ , vol.38 , Issue.7 , pp. 919-938
    • Erlandsson, M.1    Borg, M.2
  • 5
    • 50149095336 scopus 로고    scopus 로고
    • A critical review of building environmental assessment tools
    • Haapio A., Viitaniemi P. A critical review of building environmental assessment tools. Environ Impact Assess Rev 2008, 28:469-482.
    • (2008) Environ Impact Assess Rev , vol.28 , pp. 469-482
    • Haapio, A.1    Viitaniemi, P.2
  • 6
    • 57949103740 scopus 로고    scopus 로고
    • Relevance of simplifications in LCA of building components
    • Kellenberger D., Althaus H.J. Relevance of simplifications in LCA of building components. Build Environ April 2009, 44(4):818-825.
    • (2009) Build Environ , vol.44 , Issue.4 , pp. 818-825
    • Kellenberger, D.1    Althaus, H.J.2
  • 7
    • 80053174632 scopus 로고    scopus 로고
    • Comparative assessment of life cycle impacts of curtain wall mullions
    • Azari N.R., Kim Y.W. Comparative assessment of life cycle impacts of curtain wall mullions. Build Environ 2012, 48:135-145.
    • (2012) Build Environ , vol.48 , pp. 135-145
    • Azari, N.R.1    Kim, Y.W.2
  • 8
    • 80755175923 scopus 로고    scopus 로고
    • A comparative life cycle assessment of a transparent composite façade system and a glass curtain wall system
    • Kim K.E. A comparative life cycle assessment of a transparent composite façade system and a glass curtain wall system. Energy Build December 2011, 43(12):3436-3445.
    • (2011) Energy Build , vol.43 , Issue.12 , pp. 3436-3445
    • Kim, K.E.1
  • 9
    • 0034276231 scopus 로고    scopus 로고
    • Window and advanced glazing systems life cycle assessment
    • Citherlet S., Di Guglielmo F., Gay J.B. Window and advanced glazing systems life cycle assessment. Energy Build 2000, 32:225-234.
    • (2000) Energy Build , vol.32 , pp. 225-234
    • Citherlet, S.1    Di Guglielmo, F.2    Gay, J.B.3
  • 11
    • 0036136441 scopus 로고    scopus 로고
    • Study of solar walls - validating a simulation model
    • Zalewski L., Lassue S., Duthoit B., Butez M. Study of solar walls - validating a simulation model. Build Environ 2002, 37:109-121.
    • (2002) Build Environ , vol.37 , pp. 109-121
    • Zalewski, L.1    Lassue, S.2    Duthoit, B.3    Butez, M.4
  • 12
    • 34248659380 scopus 로고    scopus 로고
    • Numerical study on the thermal behavior of classical or composite Trombe solar walls
    • Shen J., Lassue S., Zalewski L., Huang D. Numerical study on the thermal behavior of classical or composite Trombe solar walls. Energy Build 2007, 39:962-974.
    • (2007) Energy Build , vol.39 , pp. 962-974
    • Shen, J.1    Lassue, S.2    Zalewski, L.3    Huang, D.4
  • 13
    • 84857050664 scopus 로고    scopus 로고
    • The behaviour of solar walls in residential buildings with different insulation levels: an experimental and numerical study
    • Stazi F., Mastrucci A., Di Perna C. The behaviour of solar walls in residential buildings with different insulation levels: an experimental and numerical study. Energy Build 2012, 47:217-229.
    • (2012) Energy Build , vol.47 , pp. 217-229
    • Stazi, F.1    Mastrucci, A.2    Di Perna, C.3
  • 14
    • 0018752108 scopus 로고
    • Performance effects of Trombe wall control strategies
    • Sebald A.V., Clinton J.R., Langenbacher F. Performance effects of Trombe wall control strategies. Solar Energy 1979, 23:479-487.
    • (1979) Solar Energy , vol.23 , pp. 479-487
    • Sebald, A.V.1    Clinton, J.R.2    Langenbacher, F.3
  • 15
    • 0032003576 scopus 로고    scopus 로고
    • A parametric study of Trombe walls for passive cooling of buildings
    • Gan G. A parametric study of Trombe walls for passive cooling of buildings. Energy Build 1998, 27:37-43.
    • (1998) Energy Build , vol.27 , pp. 37-43
    • Gan, G.1
  • 16
    • 0027664191 scopus 로고
    • Overheating caused by passive solar elements in Tunis. Effectiveness of some way to prevent it
    • Ghrab-Morcos N., Bouden C., Franchisseur R. Overheating caused by passive solar elements in Tunis. Effectiveness of some way to prevent it. Renewable Energy 1993, 3(6/7):801-811.
    • (1993) Renewable Energy , vol.3 , Issue.6-7 , pp. 801-811
    • Ghrab-Morcos, N.1    Bouden, C.2    Franchisseur, R.3
  • 17
    • 0033734116 scopus 로고    scopus 로고
    • Experimental study of passive systems thermal performance
    • Blasco Lucas I., Hoesé L., Pontoriero D. Experimental study of passive systems thermal performance. Renewable Energy 2000, 19:39-45.
    • (2000) Renewable Energy , vol.19 , pp. 39-45
    • Blasco Lucas, I.1    Hoesé, L.2    Pontoriero, D.3
  • 18
    • 80051578408 scopus 로고    scopus 로고
    • Optimum design of Trombe wall system in Mediterranean region
    • Jaber S., Ajib S. Optimum design of Trombe wall system in Mediterranean region. Solar Energy 2011, 85:1891-1898.
    • (2011) Solar Energy , vol.85 , pp. 1891-1898
    • Jaber, S.1    Ajib, S.2
  • 21
    • 84865769743 scopus 로고    scopus 로고
    • SimaPro LCA Software, Pre Consultants, The Netherlands.
    • SimaPro LCA Software, Pre Consultants, The Netherlands.
  • 22
    • 34547867427 scopus 로고    scopus 로고
    • Development and validation of the unvented Trombe wall model in EnergyPlus
    • Master's thesis, University of Illinois at Urbana-Champaign
    • Ellis PG, Development and validation of the unvented Trombe wall model in EnergyPlus. Master's thesis, University of Illinois at Urbana-Champaign, 2003.
    • (2003)
    • Ellis, P.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.