-
1
-
-
0027981834
-
The rupture rate of acute flexor tendon repairs mobilized by the controlled active motion regimen
-
D. Elliot, N.S. Moiemen, A.F. Flemming, S.B. Harris, A.J. Foster The rupture rate of acute flexor tendon repairs mobilized by the controlled active motion regimen J Hand Surg 19B 1994 607 612
-
(1994)
J Hand Surg
, vol.19
, pp. 607-612
-
-
Elliot, D.1
Moiemen, N.S.2
Flemming, A.F.3
Harris, S.B.4
Foster, A.J.5
-
3
-
-
19944399407
-
Repair of zone II flexor digitorum profundus lacerations using varying suture sizes: A comparative biomechanical study
-
G. Alavanja, E. Dailey, D.P. Mass Repair of zone II flexor digitorum profundus lacerations using varying suture sizes: a comparative biomechanical study J Hand Surg 30A 2005 448 454
-
(2005)
J Hand Surg
, vol.30
, pp. 448-454
-
-
Alavanja, G.1
Dailey, E.2
Mass, D.P.3
-
4
-
-
0035076123
-
Effect of suture locking and suture caliber on fatigue strength of flexor tendon repairs
-
K.A. Barrie, S.L. Tomak, J. Cholewicki, G.A. Merrell, S.W. Wolfe Effect of suture locking and suture caliber on fatigue strength of flexor tendon repairs J Hand Surg 26A 2001 340 346
-
(2001)
J Hand Surg
, vol.26
, pp. 340-346
-
-
Barrie, K.A.1
Tomak, S.L.2
Cholewicki, J.3
Merrell, G.A.4
Wolfe, S.W.5
-
5
-
-
0033660226
-
The effect of knot location, suture material, and suture size on the gliding resistance of flexor tendons
-
T. Momose, P.C. Amadio, C. Zhao, M.E. Zobitz, K.N. An The effect of knot location, suture material, and suture size on the gliding resistance of flexor tendons J Biomed Mater Res 53 2000 806 811
-
(2000)
J Biomed Mater Res
, vol.53
, pp. 806-811
-
-
Momose, T.1
Amadio, P.C.2
Zhao, C.3
Zobitz, M.E.4
An, K.N.5
-
6
-
-
31544439600
-
Influence of core suture purchase length on strength of four-strand tendon repairs
-
Y. Cao, B. Zhu, R.G. Xie, J.B. Tang Influence of core suture purchase length on strength of four-strand tendon repairs J Hand Surg 31A 2006 107 112
-
(2006)
J Hand Surg
, vol.31
, pp. 107-112
-
-
Cao, Y.1
Zhu, B.2
Xie, R.G.3
Tang, J.B.4
-
7
-
-
0034530435
-
The mechanical properties of locking and grasping suture loop configurations in four-strand core suture techniques
-
A. Wada, H. Kubota, H. Hatanaka, S. Hotokezaka, H. Miura, Y. Iwamoto The mechanical properties of locking and grasping suture loop configurations in four-strand core suture techniques J Hand Surg 25B 2000 548 551
-
(2000)
J Hand Surg
, vol.25
, pp. 548-551
-
-
Wada, A.1
Kubota, H.2
Hatanaka, H.3
Hotokezaka, S.4
Miura, H.5
Iwamoto, Y.6
-
8
-
-
0029118581
-
Comparative mechanical analysis of dorsal versus palmar placement of core suture for flexor tendon repairs
-
O. Soejima, E. Diao, J.C. Lotz, J.S. Hariharan Comparative mechanical analysis of dorsal versus palmar placement of core suture for flexor tendon repairs J Hand Surg 20A 1995 801 807
-
(1995)
J Hand Surg
, vol.20
, pp. 801-807
-
-
Soejima, O.1
Diao, E.2
Lotz, J.C.3
Hariharan, J.S.4
-
9
-
-
0028791276
-
Work of flexion after flexor tendon repair according to the placement of sutures
-
M. Aoki, P.R. Manske, D.L. Pruitt, H. Kubota, B.J. Larson Work of flexion after flexor tendon repair according to the placement of sutures Clin Orthop Relat Res 320 1995 205 210
-
(1995)
Clin Orthop Relat Res
, vol.320
, pp. 205-210
-
-
Aoki, M.1
Manske, P.R.2
Pruitt, D.L.3
Kubota, H.4
Larson, B.J.5
-
10
-
-
0022189693
-
Suture materials and suture techniques used in tendon repair
-
L.D. Ketchum Suture materials and suture techniques used in tendon repair Hand Clin 1 1985 43 53
-
(1985)
Hand Clin
, vol.1
, pp. 43-53
-
-
Ketchum, L.D.1
-
11
-
-
0036095251
-
Comparative biomechanical performances of 4-strand core suture repairs for zone II flexor tendon lacerations
-
J.G. Angeles, H. Heminger, D.P. Mass Comparative biomechanical performances of 4-strand core suture repairs for zone II flexor tendon lacerations J Hand Surg 27A 2002 508 517
-
(2002)
J Hand Surg
, vol.27
, pp. 508-517
-
-
Angeles, J.G.1
Heminger, H.2
Mass, D.P.3
-
12
-
-
3142771250
-
Optimizing biomechanical performance of the 4-strand cruciate flexor tendon repair
-
E. Dona, M.P. Gianoutsos, W.R. Walsh Optimizing biomechanical performance of the 4-strand cruciate flexor tendon repair J Hand Surg 29A 2004 571 580
-
(2004)
J Hand Surg
, vol.29
, pp. 571-580
-
-
Dona, E.1
Gianoutsos, M.P.2
Walsh, W.R.3
-
13
-
-
8644247576
-
A comparative analysis of the biomechanical behaviour of five flexor tendon core sutures
-
A. Viinikainen, H. Gransson, K. Huovinen, M. Kellomki, P. Rokkanen A comparative analysis of the biomechanical behaviour of five flexor tendon core sutures J Hand Surg 29B 2004 536 543
-
(2004)
J Hand Surg
, vol.29
, pp. 536-543
-
-
Viinikainen, A.1
Gransson, H.2
Huovinen, K.3
Kellomki, M.4
Rokkanen, P.5
-
14
-
-
0032451633
-
Two-, four-, and six-strand zone II flexor tendon repairs: An in situ biomechanical comparison using a cadaver model
-
R. Thurman, T.E. Trumble, D.P. Hanel, A.F. Tencer, P.K. Kiser Two-, four-, and six-strand zone II flexor tendon repairs: an in situ biomechanical comparison using a cadaver model J Hand Surg 23A 1998 261 265
-
(1998)
J Hand Surg
, vol.23
, pp. 261-265
-
-
Thurman, R.1
Trumble, T.E.2
Hanel, D.P.3
Tencer, A.F.4
Kiser, P.K.5
-
15
-
-
0033862301
-
The role of multiple strands and locking sutures on gap formation of flexor tendon repairs during cyclical loading
-
K.A. Barrie, S.L. Tomak, J. Cholewicki, S.W. Wolfe The role of multiple strands and locking sutures on gap formation of flexor tendon repairs during cyclical loading J Hand Surg 25A 2000 714 720
-
(2000)
J Hand Surg
, vol.25
, pp. 714-720
-
-
Barrie, K.A.1
Tomak, S.L.2
Cholewicki, J.3
Wolfe, S.W.4
-
16
-
-
34247643123
-
Flexor tendon repairs: The impact of FiberWire on grasping and locking core sutures
-
B. Miller, S.D. Dodds, A. deMars, N. Zagoreas, T. Waitayawinyu, T.E. Trumble Flexor tendon repairs: the impact of FiberWire on grasping and locking core sutures J Hand Surg 32A 2007 591 596
-
(2007)
J Hand Surg
, vol.32
, pp. 591-596
-
-
Miller, B.1
Dodds, S.D.2
Demars, A.3
Zagoreas, N.4
Waitayawinyu, T.5
Trumble, T.E.6
-
17
-
-
22544446740
-
A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair
-
T.M. Lawrence, T.R.C. Davis A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair J Hand Surg 30A 2005 836 841
-
(2005)
J Hand Surg
, vol.30
, pp. 836-841
-
-
Lawrence, T.M.1
Davis, T.R.C.2
-
18
-
-
0002839219
-
The six-strand technique for flexor tendon repair
-
B.H. Lim, T.M. Tsai The six-strand technique for flexor tendon repair Atlas Hand Clin 1 1996 65 76
-
(1996)
Atlas Hand Clin
, vol.1
, pp. 65-76
-
-
Lim, B.H.1
Tsai, T.M.2
-
19
-
-
45849104839
-
Comparative biomechanic study of flexor tendon repair using FiberWire
-
T. Waitayawinyu, P.A. Martineau, S. Luria, D.P. Hanel, T.E. Trumble Comparative biomechanic study of flexor tendon repair using FiberWire J Hand Surg 33A 2008 701 708
-
(2008)
J Hand Surg
, vol.33
, pp. 701-708
-
-
Waitayawinyu, T.1
Martineau, P.A.2
Luria, S.3
Hanel, D.P.4
Trumble, T.E.5
-
20
-
-
0018424934
-
The locking loop tendon suture
-
D.G. Pennington The locking loop tendon suture Plast Reconstr Surg 63 1979 648 652
-
(1979)
Plast Reconstr Surg
, vol.63
, pp. 648-652
-
-
Pennington, D.G.1
-
21
-
-
0031405345
-
Differences between locking loops and grasping loops: Effects on 2-strand core suture
-
S. Hotokezaka, P.R. Manske Differences between locking loops and grasping loops: effects on 2-strand core suture J Hand Surg 22A 1997 995 1003
-
(1997)
J Hand Surg
, vol.22
, pp. 995-1003
-
-
Hotokezaka, S.1
Manske, P.R.2
-
22
-
-
0034045166
-
Effect of suture size on locking and grasping flexor tendon repair techniques
-
H. Hatanaka, P.R. Manske Effect of suture size on locking and grasping flexor tendon repair techniques Clin Orthop Relat Res 375 2000 267 274
-
(2000)
Clin Orthop Relat Res
, vol.375
, pp. 267-274
-
-
Hatanaka, H.1
Manske, P.R.2
-
23
-
-
0032745605
-
A comparative analysis of the six-strand double-loop flexor tendon repair and three other techniques: A human cadaveric study
-
R.S. Gill, B.H. Lim, R.A. Shatford, E. Toth, M.J. Voor, T.M. Tsai A comparative analysis of the six-strand double-loop flexor tendon repair and three other techniques: a human cadaveric study J Hand Surg 24A 1999 1315 1322
-
(1999)
J Hand Surg
, vol.24
, pp. 1315-1322
-
-
Gill, R.S.1
Lim, B.H.2
Shatford, R.A.3
Toth, E.4
Voor, M.J.5
Tsai, T.M.6
-
24
-
-
0028961555
-
Effect of suture knots on tensile strength of repaired canine flexor tendons
-
M. Aoki, D.L. Pruitt, H. Kubota, P.R. Manske Effect of suture knots on tensile strength of repaired canine flexor tendons J Hand Surg 20B 1995 72 75
-
(1995)
J Hand Surg
, vol.20
, pp. 72-75
-
-
Aoki, M.1
Pruitt, D.L.2
Kubota, H.3
Manske, P.R.4
-
25
-
-
63549103265
-
Comparison of 1- and 2-knot, 4-strand, double-modified kessler tendon repairs in a porcine model
-
L. Rees, A. Matthews, S.D. Masouros, A.M.J. Bull, R. Haywood Comparison of 1- and 2-knot, 4-strand, double-modified kessler tendon repairs in a porcine model J Hand Surg 34A 2009 705 709
-
(2009)
J Hand Surg
, vol.34
, pp. 705-709
-
-
Rees, L.1
Matthews, A.2
Masouros, S.D.3
Bull, A.M.J.4
Haywood, R.5
-
26
-
-
0028964631
-
Biomechanical and clinical evaluation of the epitenon-first technique of flexor tendon repair
-
R. Panandrea, W.H. Seitz Jr, P. Shapiro, B. Borden Biomechanical and clinical evaluation of the epitenon-first technique of flexor tendon repair J Hand Surg 20A 1995 261 266
-
(1995)
J Hand Surg
, vol.20
, pp. 261-266
-
-
Panandrea, R.1
Seitz Jr., W.H.2
Shapiro, P.3
Borden, B.4
-
27
-
-
18144409855
-
The porcine forelimb as a model for human flexor tendon surgery
-
A.M. Smith, J.A. Forder, S.R. Annapureddy, K.S.K. Reddy, A.A. Amis The porcine forelimb as a model for human flexor tendon surgery J Hand Surg 30B 2005 307 309
-
(2005)
J Hand Surg
, vol.30
, pp. 307-309
-
-
Smith, A.M.1
Forder, J.A.2
Annapureddy, S.R.3
Reddy, K.S.K.4
Amis, A.A.5
-
28
-
-
0001874310
-
Flexor tendon injuries: I: Foundations of treatment
-
J.W. Strickland Flexor tendon injuries: I Foundations of treatment J AM Acad Orthop Surg 3 1995 44 54
-
(1995)
J AM Acad Orthop Surg
, vol.3
, pp. 44-54
-
-
Strickland, J.W.1
-
29
-
-
0009150002
-
The Indiana method of flexor tendon repair
-
J.W. Strickland The Indiana method of flexor tendon repair Atlas Hand Clin 1 1996 77 103
-
(1996)
Atlas Hand Clin
, vol.1
, pp. 77-103
-
-
Strickland, J.W.1
-
30
-
-
0034107209
-
Development of flexor tendon surgery: Twenty-five years in progress
-
J.W. Strickland Development of flexor tendon surgery: twenty-five years in progress J Hand Surg 25A 2000 214 235
-
(2000)
J Hand Surg
, vol.25
, pp. 214-235
-
-
Strickland, J.W.1
|