메뉴 건너뛰기




Volumn 37, Issue 9, 2012, Pages 1868-1873

Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: A prospective clinical cohort study

Author keywords

Distal radius fracture; muscle repair; pronator quadratus; volar plating; wrist

Indexed keywords

ADULT; ARM MUSCLE; ARTICLE; BODY POSTURE; BONE RADIOGRAPHY; CLINICAL ARTICLE; CLIP; FEMALE; FRACTURE TREATMENT; GRIP STRENGTH; HUMAN; INJURY SEVERITY; MALE; MUSCLE INJURY; PRIORITY JOURNAL; PRONATOR QUADRATUS MUSCLE; PROSPECTIVE STUDY; RADIUS FRACTURE; RANGE OF MOTION; VOLAR PLATE FIXATION;

EID: 84865316426     PISSN: 03635023     EISSN: 15316564     Source Type: Journal    
DOI: 10.1016/j.jhsa.2012.06.005     Document Type: Article
Times cited : (56)

References (15)
  • 1
    • 34548487815 scopus 로고    scopus 로고
    • Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: A case report
    • R.A. Klug, C.M. Press, M.H. Gonzalez Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report J Hand Surg 32A 2007 984 988
    • (2007) J Hand Surg , vol.32 , pp. 984-988
    • Klug, R.A.1    Press, C.M.2    Gonzalez, M.H.3
  • 2
    • 0037384120 scopus 로고    scopus 로고
    • Vascular anatomy of the palmar surfaces of the distal radius and ulna; Its relevance to pedicled bone grafts at the distal palmar forearm
    • M. Haerle, H.E. Schaller, C. Mathoulin Vascular anatomy of the palmar surfaces of the distal radius and ulna; its relevance to pedicled bone grafts at the distal palmar forearm J Hand Surg 28B 2003 131 136
    • (2003) J Hand Surg , vol.28 , pp. 131-136
    • Haerle, M.1    Schaller, H.E.2    Mathoulin, C.3
  • 3
    • 0017209427 scopus 로고
    • The pronator quadratus in motions and in stabilization of the radius and ulna at the distal radioulnar joint
    • R.K. Johnson, M.M. Shrewsbury The pronator quadratus in motions and in stabilization of the radius and ulna at the distal radioulnar joint J Hand Surg 1 1976 205 209
    • (1976) J Hand Surg , vol.1 , pp. 205-209
    • Johnson, R.K.1    Shrewsbury, M.M.2
  • 4
    • 0034578071 scopus 로고    scopus 로고
    • The treatment of unstable distal radius fractures with volar fixation
    • J.L. Orbay The treatment of unstable distal radius fractures with volar fixation Hand Surg 5 2000 103 112
    • (2000) Hand Surg , vol.5 , pp. 103-112
    • Orbay, J.L.1
  • 6
    • 0036023516 scopus 로고    scopus 로고
    • Failure of reinserted short external rotator muscles after total hip arthroplasty
    • T. Stahelin, P. Vienne, O. Hersche Failure of reinserted short external rotator muscles after total hip arthroplasty J Arthroplasty 17 2002 604 607
    • (2002) J Arthroplasty , vol.17 , pp. 604-607
    • Stahelin, T.1    Vienne, P.2    Hersche, O.3
  • 7
    • 0026590993 scopus 로고
    • Piriformis tendon repair failure after total hip replacement
    • J.T. Kao, S.T. Woolson Piriformis tendon repair failure after total hip replacement Orthop Rev 21 1992 171 174
    • (1992) Orthop Rev , vol.21 , pp. 171-174
    • Kao, J.T.1    Woolson, S.T.2
  • 8
    • 22544440851 scopus 로고    scopus 로고
    • Volar plate fixation of distal radius fractures
    • J.L. Orbay Volar plate fixation of distal radius fractures Hand Clin 21 2005 347 354
    • (2005) Hand Clin , vol.21 , pp. 347-354
    • Orbay, J.L.1
  • 9
    • 77953898375 scopus 로고    scopus 로고
    • Flexor tendon irritations after locked plate fixation of the distal radius with the 3.5 mm T-plate: Identification of risk factors [in German]
    • A. Ateschrang, F. Stuby, F. Werdin, H.E. Schaller, K. Weise, D. Albrecht Flexor tendon irritations after locked plate fixation of the distal radius with the 3.5 mm T-plate: identification of risk factors [in German] Z Orthop Unfall 148 2010 319 325
    • (2010) Z Orthop Unfall , vol.148 , pp. 319-325
    • Ateschrang, A.1    Stuby, F.2    Werdin, F.3    Schaller, H.E.4    Weise, K.5    Albrecht, D.6
  • 10
    • 70350566655 scopus 로고    scopus 로고
    • Quantification of pronator quadratus contribution to isometric pronation torque of the forearm
    • M.O. McConkey, T.D. Schwab, A. Travlos, T.R. Oxland, T. Goetz Quantification of pronator quadratus contribution to isometric pronation torque of the forearm J Hand Surg 34A 2009 1612 1617
    • (2009) J Hand Surg , vol.34 , pp. 1612-1617
    • McConkey, M.O.1    Schwab, T.D.2    Travlos, A.3    Oxland, T.R.4    Goetz, T.5
  • 11
    • 0346399753 scopus 로고    scopus 로고
    • Electromyographic activity and strength during maximum isometric pronation and supination efforts in healthy adults
    • K.D. Gordon, R.D. Pardo, J.A. Johnson, G.J. King, T.A. Miller Electromyographic activity and strength during maximum isometric pronation and supination efforts in healthy adults J Orthop Res 22 2004 208 213
    • (2004) J Orthop Res , vol.22 , pp. 208-213
    • Gordon, K.D.1    Pardo, R.D.2    Johnson, J.A.3    King, G.J.4    Miller, T.A.5
  • 12
    • 2442677810 scopus 로고    scopus 로고
    • Soft-tissue stabilizers of the distal radioulnar joint: An in vitro kinematic study
    • W.T. Gofton, K.D. Gordon, C.E. Dunning, J.A. Johnson, G.J. King Soft-tissue stabilizers of the distal radioulnar joint: an in vitro kinematic study J Hand Surg 29A 2004 423 431
    • (2004) J Hand Surg , vol.29 , pp. 423-431
    • Gofton, W.T.1    Gordon, K.D.2    Dunning, C.E.3    Johnson, J.A.4    King, G.J.5
  • 13
    • 0344441299 scopus 로고    scopus 로고
    • Influence of the pronator quadratus and supinator muscle load on DRUJ stability
    • K.D. Gordon, C.E. Dunning, J.A. Johnson, G.J. King Influence of the pronator quadratus and supinator muscle load on DRUJ stability J Hand Surg 28A 2003 943 950
    • (2003) J Hand Surg , vol.28 , pp. 943-950
    • Gordon, K.D.1    Dunning, C.E.2    Johnson, J.A.3    King, G.J.4
  • 14
    • 79960963653 scopus 로고    scopus 로고
    • American Academy of Orthopaedic Surgeons clinical practice guideline on: The treatment of distal radius fractures
    • D.M. Lichtman, R.R. Bindra, M.I. Boyer, M.D. Putnam, D. Ring, D.J. Slutsky American Academy of Orthopaedic Surgeons clinical practice guideline on: the treatment of distal radius fractures J Bone Joint Surg 93A 2011 775 778
    • (2011) J Bone Joint Surg , vol.93 , pp. 775-778
    • Lichtman, D.M.1    Bindra, R.R.2    Boyer, M.I.3    Putnam, M.D.4    Ring, D.5    Slutsky, D.J.6
  • 15
    • 0036130725 scopus 로고    scopus 로고
    • Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    • J.L. Orbay, D.L. Fernandez Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report J Hand Surg 27A 2002 205 215
    • (2002) J Hand Surg , vol.27 , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.