메뉴 건너뛰기




Volumn 18, Issue 4, 2012, Pages 737-749

A simplified combined displacement and personalized ventilation model

Author keywords

[No Author keywords available]

Indexed keywords

AIR LAYERS; AIR MOVEMENT; AIR TEMPERATURE; CENTERLINES; DISPLACEMENT VENTILATION; EXPERIMENTAL MEASUREMENTS; HEAT SOURCES; HUMAN BODIES; MASS BALANCE EQUATIONS; MULTILAYER MODELS; PERSONALIZED VENTILATION; PERSONALIZED VENTILATION SYSTEMS; PLUME TEMPERATURE; THERMAL TRANSPORT;

EID: 84865271540     PISSN: 10789669     EISSN: None     Source Type: Journal    
DOI: 10.1080/10789669.2011.605510     Document Type: Conference Paper
Times cited : (21)

References (15)
  • 2
    • 33750364780 scopus 로고    scopus 로고
    • Simplified thermal model of spaces cooled with combined positive displacement ventilation and chilled ceiling system
    • Ayoub, M., N. Ghaddar, and K. Ghali. 2006. Simplified thermal model of spaces cooled with combined chilled ceiling and displacement ventilation system. HVAC&R 12(4):1005-30. (Pubitemid 44614597)
    • (2006) HVAC and R Research , vol.12 , Issue.4 , pp. 1005-1030
    • Ayoub, M.1    Ghaddar, N.2    Ghali, K.3
  • 3
    • 0032679351 scopus 로고    scopus 로고
    • Indoor air quality in rooms with cooled ceilings: Mixing ventilation or rather displacement ventilation?
    • Behne, M. 1999. Indoor air quality in rooms with cooled ceilings: Mixing ventilation or rather displacement ventilation? Energy and Buildings 30(2):155-66.
    • (1999) Energy and Buildings , vol.30 , Issue.2 , pp. 155-66
    • Behne, M.1
  • 6
    • 0003784565 scopus 로고    scopus 로고
    • Chapter 7, Momentum and buoyancy induced primary air flows. Chichester: JohnWiley and Sons
    • Etheridge, D., andM. Sandberg. 1996. Building Ventilation: Theory and Measurement. Chapter 7, Momentum and buoyancy induced primary air flows. Chichester: JohnWiley and Sons.
    • (1996) Building Ventilation: Theory and Measurement
    • Etheridge, D.1    Sandberg, M.2
  • 7
    • 77949304878 scopus 로고    scopus 로고
    • Performance of ductless personalized ventilation in conjunction with displacement ventilation: Impact of workstations layout and partitions
    • Halvonova, B., and A.K. Melikov. 2010. Performance of ductless personalized ventilation in conjunction with displacement ventilation: impact of workstations layout and partitions. HVAC & R 16(1):75-94.
    • (2010) HVAC & R , vol.16 , Issue.1 , pp. 75-94
    • Halvonova, B.1    Melikov, A.K.2
  • 9
    • 0026994420 scopus 로고
    • Indoor airflow with cooling and radiative/convective heat source
    • Jiang, Z., Q. Chen, and A. Moser (1992). Indoor airflow with cooling and radiative/convective heat source. ASHRAE Transactions 98(1):33-42.
    • (1992) ASHRAE Transactions , vol.98 , Issue.1 , pp. 33-42
    • Jiang, Z.1    Chen, Q.2    Moser, A.3
  • 10
    • 0025397867 scopus 로고
    • Emptying filing boxes: The fluid mechanics of natural ventilation
    • Linden, P., G. Lane-Serff, and D. Smeed. 1990. Emptying filing boxes: The fluid mechanics of natural ventilation. Journal of Fluid Mechanics 212:300-35.
    • (1990) Journal of Fluid Mechanics , vol.212 , pp. 300-35
    • Linden, P.1    Lane-Serff, G.2    Smeed, D.3
  • 11
    • 0000274206 scopus 로고
    • Natural convection and radiation in a panel heated room
    • Min, T., L. Schutrum, G. Parmelee, and J. Vouris. 1956. Natural convection and radiation in a panel heated room. ASHRAE Transactions 62:337-58.
    • (1956) ASHRAE Transactions , vol.62 , pp. 337-58
    • Min, T.1    Schutrum, L.2    Parmelee, G.3    Vouris, J.4
  • 13
    • 69249236145 scopus 로고    scopus 로고
    • Optimized operation of combined chilled ceiling displacement ventilation system using genetic algorithm
    • Mossolly M., N. Ghaddar, K. Gali, and L. Jensen. 2008. Optimized operation of combined chilled ceiling displacement ventilation system using genetic algorithm. ASHRAE Transactions 143(2):541-54.
    • (2008) ASHRAE Transactions , vol.143 , Issue.2 , pp. 541-54
    • Mossolly, M.1    Ghaddar, N.2    Gali, K.3    Jensen, L.4
  • 15
    • 0031618729 scopus 로고    scopus 로고
    • A critical review of displacement ventilation
    • Yuan, X., Q. Chen, and L. Glicksman. 2001. A critical review of displacement ventilation. ASHRAE Transactions 104(1):78-90.
    • (2001) ASHRAE Transactions , vol.104 , Issue.1 , pp. 78-90
    • Yuan, X.1    Chen, Q.2    Glicksman, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.