메뉴 건너뛰기




Volumn 47, Issue 8, 2012, Pages 1083-1089

Non-vacuum field desorption ion source implemented under super-atmospheric pressure

Author keywords

corona discharge; FD MS; field desorption; high pressure; super atmospheric pressure

Indexed keywords

CORONA DISCHARGES; DIELECTRIC STRENGTHS; DIRECT CURRENT; ELECTRICAL DISCHARGES; FD-MS; HIGH PRESSURE; HIGH VOLTAGE; HIGH-VACUUM CONDITIONS; LINEAR ION TRAP; NEUTRAL COMPOUNDS; NON-VACUUM; NON-VOLATILE; OPERATING PRESSURE; ORGANIC SALT; STRONG ELECTRIC FIELDS; TUNGSTEN WIRES; WORKING GAS;

EID: 84865206748     PISSN: 10765174     EISSN: 10969888     Source Type: Journal    
DOI: 10.1002/jms.3062     Document Type: Article
Times cited : (13)

References (30)
  • 1
    • 33947466822 scopus 로고
    • Applications of Field Ionization to Mass Spectrometry
    • R. Gomer, M.G. Inghram,. Applications of Field Ionization to Mass Spectrometry. J. Am. Chem. Soc. 1955, 77, 500.
    • (1955) J. Am. Chem. Soc. , vol.77 , pp. 500
    • Gomer, R.1    Inghram, M.G.2
  • 2
    • 84981830366 scopus 로고
    • Determination of the Structures of Organic Molecules and Quantitative Analyses with the Field Ionization Mass Spectrometer
    • H.D. Beckey,. Determination of the Structures of Organic Molecules and Quantitative Analyses with the Field Ionization Mass Spectrometer. Angew. Chem. Int. Ed. 1969, 8, 623-639.
    • (1969) Angew. Chem. Int. Ed. , vol.8 , pp. 623-639
    • Beckey, H.D.1
  • 4
    • 49849128566 scopus 로고
    • Field desorption mass spectrometry: A technique for the study of thermally unstable substances of low volatility
    • H.D. Beckey,. Field desorption mass spectrometry: A technique for the study of thermally unstable substances of low volatility. Int. J. Mass. Spectrom. Ion Phys. 1969, 2, 500-502.
    • (1969) Int. J. Mass. Spectrom. Ion Phys. , vol.2 , pp. 500-502
    • Beckey, H.D.1
  • 6
    • 49549160513 scopus 로고
    • Field ionization mass spectrometry with conditioned razor blades
    • P.J. Derrick, A.J.B. Robertson,. Field ionization mass spectrometry with conditioned razor blades. Int. J. Mass. Spectrom. Ion Phys. 1973, 10, 315-321.
    • (1973) Int. J. Mass. Spectrom. Ion Phys. , vol.10 , pp. 315-321
    • Derrick, P.J.1    Robertson, A.J.B.2
  • 7
    • 84987005657 scopus 로고
    • Field desorption of electrolytic solutions using untreated wire emitters
    • H.J. Heinen, U. Giessmann, F.W. Röllgen,. Field desorption of electrolytic solutions using untreated wire emitters. Organic Mass Spectrometry. 1977, 12, 710-715.
    • (1977) Organic Mass Spectrometry. , vol.12 , pp. 710-715
    • Heinen, H.J.1    Giessmann, U.2    Röllgen, F.W.3
  • 8
    • 0039929796 scopus 로고
    • High temperature activation of emitters for field ionization and field desorption mass spectrometry
    • H.D. Beckey, E. Hilt, H.R. Schulten,. High temperature activation of emitters for field ionization and field desorption mass spectrometry. J. Phy. E: Sci. Instrum. 1973, 6, 1043-1044.
    • (1973) J. Phy. E: Sci. Instrum. , vol.6 , pp. 1043-1044
    • Beckey, H.D.1    Hilt, E.2    Schulten, H.R.3
  • 9
    • 0018024153 scopus 로고
    • High-rate growth of dendrites on thin wire anodes for field desorption mass spectrometry
    • H.B. Linden, E. Hilt, H.D. Beckey,. High-rate growth of dendrites on thin wire anodes for field desorption mass spectrometry. J. Phy. E: Sci. Instrum. 1978, 11, 1033-1036. (Pubitemid 9402377)
    • (1978) Journal of Physics E: Scientific Instruments , vol.22 , Issue.10 , pp. 1033-1036
    • Linden, H.B.1    Hilt, E.2    Beckey, H.D.3
  • 10
    • 4644334124 scopus 로고    scopus 로고
    • Liquid injection field desorption ionization: A new tool for soft ionization of samples including air sensitive catalysts and non-polar hydrocarbons
    • H.B. Linden,. Liquid injection field desorption ionization: a new tool for soft ionization of samples including air sensitive catalysts and non-polar hydrocarbons. Eur. J. Mass Spectrom. 2004, 10, 459.
    • (2004) Eur. J. Mass Spectrom. , vol.10 , pp. 459
    • Linden, H.B.1
  • 12
    • 84855681389 scopus 로고    scopus 로고
    • A Liquid Injection Field Desorption/Ionization-Electrospray Ionization Combination Source for a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
    • H.B. Linden, J.H. Gross,. A Liquid Injection Field Desorption/Ionization- Electrospray Ionization Combination Source for a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer. J. Am. Soc. Mass Spectrom. 2011, 22, 2137-2144.
    • (2011) J. Am. Soc. Mass Spectrom. , vol.22 , pp. 2137-2144
    • Linden, H.B.1    Gross, J.H.2
  • 13
    • 0041434834 scopus 로고
    • Field Ionization and Field Ion Microscopy
    • In, L. Marton, C. Marton (Eds). Academic Press: London
    • E.W. Müller,. Field Ionization and Field Ion Microscopy. In Advances in Electronics and Electron Physics, L. Marton, C. Marton, (Eds). Academic Press: London, 1960, 83-179.
    • (1960) Advances in Electronics and Electron Physics , pp. 83-179
    • Müller, E.W.1
  • 14
    • 36849136137 scopus 로고
    • Mass Spectrometric Analysis of Ions from the Field Microscope
    • M.G. Inghram, R. Gomer,. Mass Spectrometric Analysis of Ions from the Field Microscope. J. Chem. Phys. 1954, 22, 1279-1280.
    • (1954) J. Chem. Phys. , vol.22 , pp. 1279-1280
    • Inghram, M.G.1    Gomer, R.2
  • 15
    • 0028320029 scopus 로고
    • Field emission, field ionization, and field desorption
    • R. Gomer,. Field emission, field ionization, and field desorption. Surf. Sci. 1994, 299-300, 129-152.
    • (1994) Surf. Sci. , vol.299-300 , pp. 129-152
    • Gomer, R.1
  • 16
    • 84987005657 scopus 로고
    • Field desorption of electrolytic solutions using untreated wire emitters
    • H.J. Heinen, U. Giessmann, F.W. Röllgen,. Field desorption of electrolytic solutions using untreated wire emitters. Org. Mass Spectrom. 1977, 12, 710-715.
    • (1977) Org. Mass Spectrom. , vol.12 , pp. 710-715
    • Heinen, H.J.1    Giessmann, U.2    Röllgen, F.W.3
  • 17
    • 33845282994 scopus 로고
    • Field desorption mass spectrometry with suppression of the high field
    • S.C. Davis, G.M. Neumann, P.J. Derrick,. Field desorption mass spectrometry with suppression of the high field. Anal. Chem. 1987, 59, 1360-1362.
    • (1987) Anal. Chem. , vol.59 , pp. 1360-1362
    • Davis, S.C.1    Neumann, G.M.2    Derrick, P.J.3
  • 18
    • 0001578509 scopus 로고
    • Electrodynamic effects in field desorption mass spectrometry
    • U. Giessmann, F.W. Röllgen,. Electrodynamic effects in field desorption mass spectrometry. Int. J. Mass. Spectrom. Ion Phys. 1981, 38, 267-279.
    • (1981) Int. J. Mass. Spectrom. Ion Phys. , vol.38 , pp. 267-279
    • Giessmann, U.1    Röllgen, F.W.2
  • 21
    • 0000217562 scopus 로고
    • Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
    • M.S. Wilm, M. Mann,. Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last? Int. J. Mass. Spectrom. Ion Processes. 1994, 136, 167-180.
    • (1994) Int. J. Mass. Spectrom. Ion Processes. , vol.136 , pp. 167-180
    • Wilm, M.S.1    Mann, M.2
  • 24
    • 80052660546 scopus 로고    scopus 로고
    • Sequential and Exhaustive Ionization of Analytes with Different Surface Activity by Probe Electrospray Ionization
    • M.K. Mandal, L.C. Chen, K. Hiraoka,. Sequential and Exhaustive Ionization of Analytes with Different Surface Activity by Probe Electrospray Ionization. J. Am. Soc. Mass Spectrom. 2011, 22, 1493-1500.
    • (2011) J. Am. Soc. Mass Spectrom. , vol.22 , pp. 1493-1500
    • Mandal, M.K.1    Chen, L.C.2    Hiraoka, K.3
  • 25
    • 77956063895 scopus 로고    scopus 로고
    • Field-based ion generation from microscale emitters on natural and artificial objects for atmospheric pressure mass spectrometry
    • A. Pirkl, K. Dreisewerd, J. Yew, S. König,. Field-based ion generation from microscale emitters on natural and artificial objects for atmospheric pressure mass spectrometry. Anal. Bioanal. Chem. 2010, 397, 3311-3316.
    • (2010) Anal. Bioanal. Chem. , vol.397 , pp. 3311-3316
    • Pirkl, A.1    Dreisewerd, K.2    Yew, J.3    König, S.4
  • 26
    • 84944488209 scopus 로고
    • Ueber die zum Funkenübergang in Luft, Wasserstoff und Kohlensäure bei verschiedenen Drucken erforderliche Potentialdifferenz
    • F. Paschen,. Ueber die zum Funkenübergang in Luft, Wasserstoff und Kohlensäure bei verschiedenen Drucken erforderliche Potentialdifferenz. Ann. Phys. 1889, 273, 69-96.
    • (1889) Ann. Phys. , vol.273 , pp. 69-96
    • Paschen, F.1
  • 27
    • 79955779355 scopus 로고    scopus 로고
    • High Pressure (>1 atm) Electrospray Ionization Mass Spectrometry
    • L.C. Chen, M.K. Mandal, K. Hiraoka,. High Pressure (>1 atm) Electrospray Ionization Mass Spectrometry. J. Am. Soc. Mass Spectrom. 2011, 22, 539-544.
    • (2011) J. Am. Soc. Mass Spectrom. , vol.22 , pp. 539-544
    • Chen, L.C.1    Mandal, M.K.2    Hiraoka, K.3
  • 28
    • 84862916775 scopus 로고    scopus 로고
    • Super-Atmospheric Pressure Electrospray Ion Source: Applied to Aqueous Solution
    • L.C. Chen, M.K. Mandal, K. Hiraoka,. Super-Atmospheric Pressure Electrospray Ion Source: Applied to Aqueous Solution. J. Am. Soc. Mass Spectrom. 2011, 22, 2108-2114.
    • (2011) J. Am. Soc. Mass Spectrom. , vol.22 , pp. 2108-2114
    • Chen, L.C.1    Mandal, M.K.2    Hiraoka, K.3
  • 30
    • 26844505533 scopus 로고
    • Field induced ion evaporation from liquid surfaces at atmospheric pressure
    • B.A. Thomson, J.V. Iribarne,. Field induced ion evaporation from liquid surfaces at atmospheric pressure. J. Chem. Phys. 1979, 71, 4451-4463.
    • (1979) J. Chem. Phys. , vol.71 , pp. 4451-4463
    • Thomson, B.A.1    Iribarne, J.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.