Volumn 6, Issue 4, 2012, Pages 288-297

Variable leaky least mean-square algorithm-based power system frequency estimation

Author keywords

[No Author keywords available]

Indexed keywords

CRITICAL CASE; DYNAMIC VARIATIONS; EXPERIMENTAL DATA; FASTER CONVERGENCE; MEAN-SQUARE; POWER SYSTEM FREQUENCIES; POWER SYSTEM FREQUENCY ESTIMATION; STEP SIZE;

EID: 84865184881     PISSN: 17518822     EISSN: None     Source Type: Journal    
DOI: 10.1049/iet-smt.2011.0103     Document Type: Article
Times cited : (47)

References (18)
  • 1
    • 43049116108 scopus 로고    scopus 로고
    • Frequency measurement of distorted signals using Fourier and zero crossing techniques
    • 10.1016/j.epsr.2008.01.008, 0378-7796
    • Djuric, M.B., and Djurisic, Z.R.: 'Frequency measurement of distorted signals using Fourier and zero crossing techniques', Electr. Power Syst. Res., 2008, 78, (8), p. 1407-141510.1016/j.epsr.2008.01.008 0378-7796
    • (2008) Electr. Power Syst. Res. , vol.78 , Issue.8 , pp. 1407-1415
    • Djuric, M.B.1    Djurisic, Z.R.2
  • 2
    • 23944487436 scopus 로고    scopus 로고
    • Power system frequency estimation using least mean square technique
    • 10.1109/TPWRD.2004.843453, 0885-8977
    • Pradhan, A.K., Routray, A., and Abir, B.: 'Power system frequency estimation using least mean square technique', IEEE Trans. Power Deliv., 2005, 20, (3), p. 1812-181610.1109/TPWRD.2004.843453 0885-8977
    • (2005) IEEE Trans. Power Deliv. , vol.20 , Issue.3 , pp. 1812-1816
    • Pradhan, A.K.1    Routray, A.2    Abir, B.3
  • 3
    • 0032628971 scopus 로고    scopus 로고
    • Frequency estimation of distorted power system signals using extended complex Kalman filter
    • 10.1109/61.772312, 0885-8977
    • Dash, P.K., Pradhan, A.K., and Panda, G.: 'Frequency estimation of distorted power system signals using extended complex Kalman filter', IEEE Trans. Power Deliv., 1999, 14, (3), p. 761-76610.1109/61.772312 0885-8977
    • (1999) IEEE Trans. Power Deliv. , vol.14 , Issue.3 , pp. 761-766
    • Dash, P.K.1    Pradhan, A.K.2    Panda, G.3
  • 4
    • 0032647648 scopus 로고    scopus 로고
    • Accurate measurement of power system frequency using a digital signal processing technique
    • 10.1109/19.755064, 0018-9456
    • Sidhu, T.S.: 'Accurate measurement of power system frequency using a digital signal processing technique', IEEE Trans. Instrum. Meas., 1999, 48, (1), p. 75-8110.1109/19.755064 0018-9456
    • (1999) IEEE Trans. Instrum. Meas. , vol.48 , Issue.1 , pp. 75-81
    • Sidhu, T.S.1
  • 5
    • 76149099866 scopus 로고    scopus 로고
    • Frequency estimation of three-phase power system using weighted least square algorithm and adaptive FIR-filtering
    • 10.1109/TIM.2009.2023816, 0018-9456
    • Kusljevic, M.D., Tomic, J.J., and Jovanovic, L.D.: 'Frequency estimation of three-phase power system using weighted least square algorithm and adaptive FIR-filtering', IEEE Trans. Instrum. Meas., 2010, 59, (2), p. 322-32910.1109/TIM.2009.2023816 0018-9456
    • (2010) IEEE Trans. Instrum. Meas. , vol.59 , Issue.2 , pp. 322-329
    • Kusljevic, M.D.1    Tomic, J.J.2    Jovanovic, L.D.3
  • 6
    • 0031677593 scopus 로고    scopus 로고
    • An iterative technique for fast and accurate measurement of power system frequency
    • 10.1109/61.660863, 0885-8977
    • Sidhu, T.S., and Sachdev, M.S.: 'An iterative technique for fast and accurate measurement of power system frequency', IEEE Trans. Power Deliv., 1998, 13, (1), p. 109-11510.1109/61.660863 0885-8977
    • (1998) IEEE Trans. Power Deliv. , vol.13 , Issue.1 , pp. 109-115
    • Sidhu, T.S.1    Sachdev, M.S.2
  • 7
    • 0032733448 scopus 로고    scopus 로고
    • Real-time frequency and harmonic evaluation using artificial neural networks
    • 10.1109/61.736681, 0885-8977
    • Lai, L.L., Chan, W.L., Tse, C.T., and So, A.T.P.: 'Real-time frequency and harmonic evaluation using artificial neural networks', IEEE Trans. Power Deliv., 1999, 14, (1), p. 52-5910.1109/61.736681 0885-8977
    • (1999) IEEE Trans. Power Deliv. , vol.14 , Issue.1 , pp. 52-59
    • Lai, L.L.1    Chan, W.L.2    Tse, C.T.3    So, A.T.P.4
  • 8
    • 33846600925 scopus 로고    scopus 로고
    • Adaline and its application in power quality disturbances detection and frequency tracking
    • 10.1016/j.epsr.2006.04.007, 0378-7796
    • Zhou, Q., Ai, Y., and Xu, W.: 'Adaline and its application in power quality disturbances detection and frequency tracking', Electr. Power Syst. Res., 2007, 77, (5-6), p. 462-46910.1016/j.epsr.2006.04.007 0378-7796
    • (2007) Electr. Power Syst. Res. , vol.77 , Issue.5-6 , pp. 462-469
    • Zhou, Q.1    Ai, Y.2    Xu, W.3
  • 9
    • 0038685717 scopus 로고    scopus 로고
    • Frequency and harmonics evaluation in power network using fuzzy regression technique
    • 10.1016/S0378-7796(03)00043-9, 0378-7796
    • Soliman, S.A., Alammari, R.A., and El-Hawary, M.E.: 'Frequency and harmonics evaluation in power network using fuzzy regression technique', Electr. Power Syst. Res., 2003, 66, (2), p. 171-17710.1016/S0378-7796(03)00043-9 0378-7796
    • (2003) Electr. Power Syst. Res. , vol.66 , Issue.2 , pp. 171-177
    • Soliman, S.A.1    Alammari, R.A.2    El-Hawary, M.E.3
  • 10
    • 0034272625 scopus 로고    scopus 로고
    • A genetic based algorithm for frequency relaying applications
    • 10.1016/S0378-7796(00)00080-8, 0378-7796
    • El-Naggar, K.M., and Youssef, H.K.M.: 'A genetic based algorithm for frequency relaying applications', Electr. Power Syst. Res., 2000, 55, (3), p. 173-17810.1016/S0378-7796(00)00080-8 0378-7796
    • (2000) Electr. Power Syst. Res. , vol.55 , Issue.3 , pp. 173-178
    • El-Naggar, K.M.1    Youssef, H.K.M.2
  • 11
    • 11144316986 scopus 로고    scopus 로고
    • Power system frequency estimation based on simulated annealing: a variable frequency model
    • Soliman, S.A., Alammari, R.A., Mantaway, A.H., and El-Hawary, M.E.: 'Power system frequency estimation based on simulated annealing: a variable frequency model', Sci. Iranica, 2004, 11, (3), p. 218-224
    • (2004) Sci. Iranica , vol.11 , Issue.3 , pp. 218-224
    • Soliman, S.A.1    Alammari, R.A.2    Mantaway, A.H.3    El-Hawary, M.E.4
  • 12
    • 0026896422 scopus 로고
    • A variable step size LMS algorithm
    • 10.1109/78.143435, 1053-587X
    • Kwong, R.H., and Johnston, E.W.: 'A variable step size LMS algorithm', IEEE Trans. Signal Process., 1992, 40, (2), p. 1633-164210.1109/78.143435 1053-587X
    • (1992) IEEE Trans. Signal Process. , vol.40 , Issue.2 , pp. 1633-1642
    • Kwong, R.H.1    Johnston, E.W.2
  • 13
    • 0031700893 scopus 로고    scopus 로고
    • Application of leaky extended LMS (XLMS) algorithm in stereophonic acoustic echo cancellation
    • 10.1016/S0165-1684(97)00178-3, 0165-1684
    • Hoya, T., Loke, Y., Chambers, J.A., and Naylor, P.A.: 'Application of leaky extended LMS (XLMS) algorithm in stereophonic acoustic echo cancellation', Signal Process., 1998, 64, (1), p. 87-9110.1016/S0165-1684(97)00178-3 0165-1684
    • (1998) Signal Process. , vol.64 , Issue.1 , pp. 87-91
    • Hoya, T.1    Loke, Y.2    Chambers, J.A.3    Naylor, P.A.4
  • 14
    • 0031121569 scopus 로고    scopus 로고
    • Leaky LMS algorithm: MSE analysis for Gaussian data
    • 10.1109/78.564181, 1053-587X
    • Mayyas, K., and Aboulnasr, T.: 'Leaky LMS algorithm: MSE analysis for Gaussian data', IEEE Trans. Signal Process., 1997, 45, (4), p. 927-93410.1109/78.564181 1053-587X
    • (1997) IEEE Trans. Signal Process. , vol.45 , Issue.4 , pp. 927-934
    • Mayyas, K.1    Aboulnasr, T.2
  • 16
    • 33947134818 scopus 로고    scopus 로고
    • On the LMS algorithm with constant and variable leakage factor in a nonlinear environment
    • 10.1109/TSP.2006.879274, 1053-587X
    • Tobias, O.J., and Seara, R.: 'On the LMS algorithm with constant and variable leakage factor in a nonlinear environment', IEEE Trans. Signal Process., 2006, 54, (9), p. 3448-345810.1109/TSP.2006.879274 1053-587X
    • (2006) IEEE Trans. Signal Process. , vol.54 , Issue.9 , pp. 3448-3458
    • Tobias, O.J.1    Seara, R.2
  • 17
    • 37749016327 scopus 로고    scopus 로고
    • Frequency estimation of distorted power system signals using a robust algorithm
    • 10.1109/TPWRD.2007.911143, 0885-8977
    • Huang, C.-H., Lee, C.-H., Shih, K.-J., and Wang, Y.-J.: 'Frequency estimation of distorted power system signals using a robust algorithm', IEEE Trans. Power Deliv., 2008, 23, (1), p. 41-5110.1109/TPWRD.2007.911143 0885-8977
    • (2008) IEEE Trans. Power Deliv. , vol.23 , Issue.1 , pp. 41-51
    • Huang, C.1    Lee, C.2    Shih, K.3    Wang, Y.4
  • 18
    • 0031102202 scopus 로고    scopus 로고
    • A robust variable step-size LMS-type algorithm: analysis and simulations
    • 10.1109/78.558478, 1053-587X
    • Aboulnasr, T.: 'A robust variable step-size LMS-type algorithm: analysis and simulations', IEEE Trans. Signal Process., 1997, 43, (3), p. 631-63910.1109/78.558478 1053-587X
    • (1997) IEEE Trans. Signal Process. , vol.43 , Issue.3 , pp. 631-639
    • Aboulnasr, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.