메뉴 건너뛰기




Volumn 120, Issue 3, 2012, Pages 177-184

On-site adequacy evaluations performed by cytotechnologists: Correlation with final interpretations of 5241 image-guided fine-needle aspiration biopsies

Author keywords

Adequacy evaluation; Cytotechnologist; Fine needle aspiration biopsy; Image guided biopsy; Interventional radiology

Indexed keywords

ARTICLE; BENIGN TUMOR; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; CYTOLOGY; CYTOTECHNOLOGIST; DATA BASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; DIAGNOSTIC VALUE; FINE NEEDLE ASPIRATION BIOPSY; HUMAN; HUMAN TISSUE; MALIGNANT NEOPLASTIC DISEASE; NUCLEAR MAGNETIC RESONANCE IMAGING; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; COHORT ANALYSIS; COMPARATIVE STUDY; CONFIDENCE INTERVAL; CYTODIAGNOSIS; DIFFERENTIAL DIAGNOSIS; EVALUATION; FACTUAL DATABASE; FEMALE; IMMUNOHISTOCHEMISTRY; INTERVENTIONAL RADIOLOGY; LABORATORY DIAGNOSIS; MALE; METHODOLOGY; NEEDLE BIOPSY; NEOPLASM; PATHOLOGY; RADIOGRAPHY; RETROSPECTIVE STUDY; RISK ASSESSMENT; SENSITIVITY AND SPECIFICITY;

EID: 84865108136     PISSN: None     EISSN: 19346638     Source Type: Journal    
DOI: 10.1002/cncy.20184     Document Type: Article
Times cited : (51)

References (34)
  • 1
    • 0031939555 scopus 로고    scopus 로고
    • Percutaneous abdominal biopsy: Cost-identification analysis
    • Silverman SG, Deuson TE, Kane N, et al. Percutaneous abdominal biopsy: cost-identification analysis. Radiology. 1998;206:429-435.
    • (1998) Radiology , vol.206 , pp. 429-435
    • Silverman, S.G.1    Deuson, T.E.2    Kane, N.3
  • 2
    • 77956151819 scopus 로고    scopus 로고
    • Effect of advanced imaging technology on how biopsies are done and who does them
    • Kwan SW, Bhargavan M, Kerlan RK, Sunshine JH. Effect of advanced imaging technology on how biopsies are done and who does them. Radiology. 2010;256:751-758.
    • (2010) Radiology , vol.256 , pp. 751-758
    • Kwan, S.W.1    Bhargavan, M.2    Kerlan, R.K.3    Sunshine, J.H.4
  • 3
    • 65649124130 scopus 로고    scopus 로고
    • Paediatric interventional radiology
    • Roebuck D. Paediatric interventional radiology. Pediatr Radiol. 2009;39(Suppl 3):491-495.
    • (2009) Pediatr Radiol , vol.39 , Issue.SUPPL. 3 , pp. 491-495
    • Roebuck, D.1
  • 4
    • 34248659659 scopus 로고    scopus 로고
    • Can endosonographers evaluate on-site cytologic adequacya comparison with cytotechnologists
    • Savoy AD, Raimondo M, Woodward TA, et al. Can endosonographers evaluate on-site cytologic adequacyA comparison with cytotechnologists. Gastrointest Endosc. 2007; 65:953-957.
    • (2007) Gastrointest Endosc , vol.65 , pp. 953-957
    • Savoy, A.D.1    Raimondo, M.2    Woodward, T.A.3
  • 5
    • 0038310881 scopus 로고    scopus 로고
    • Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration
    • Klapman JB, Logrono R, Dye CE, Waxman I. Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration. Am J Gastroenterol. 2003;98:1289-1294.
    • (2003) Am J Gastroenterol , vol.98 , pp. 1289-1294
    • Klapman, J.B.1    Logrono, R.2    Dye, C.E.3    Waxman, I.4
  • 6
    • 66049164114 scopus 로고    scopus 로고
    • Reliability of gross visual assessment of specimen adequacy during eus-guided fna of pancreatic masses
    • Nguyen YP, Maple JT, Zhang Q, et al. Reliability of gross visual assessment of specimen adequacy during EUS-guided FNA of pancreatic masses. Gastrointest Endosc. 2009;69:1264-1270.
    • (2009) Gastrointest Endosc , vol.69 , pp. 1264-1270
    • Nguyen, Y.P.1    Maple, J.T.2    Zhang, Q.3
  • 7
    • 0036161649 scopus 로고    scopus 로고
    • Comparison of fine needle aspiration cytology and needle core biopsy in the diagnosis of radiologically detected abdominal lesions
    • Stewart CJ, Coldewey J, Stewart IS. Comparison of fine needle aspiration cytology and needle core biopsy in the diagnosis of radiologically detected abdominal lesions. J Clin Pathol. 2002;55:93-97.
    • (2002) J Clin Pathol , vol.55 , pp. 93-97
    • Stewart, C.J.1    Coldewey, J.2    Stewart, I.S.3
  • 10
    • 0347761219 scopus 로고    scopus 로고
    • Cost-effectiveness of immediate specimen adequacy assessment of thyroid fine-needle aspirations
    • Eedes CR, Wang HH. Cost-effectiveness of immediate specimen adequacy assessment of thyroid fine-needle aspirations. Am J Clin Pathol. 2004;121:64-69.
    • (2004) Am J Clin Pathol , vol.121 , pp. 64-69
    • Eedes, C.R.1    Wang, H.H.2
  • 11
    • 0036154119 scopus 로고    scopus 로고
    • Us-guided fine-needle aspiration biopsy of thyroid nodules: Adequacy of cytologic material and procedure time with and without immediate cytologic analysis
    • O'Malley ME, Weir MM, Hahn PF, Misdraji J, Wood BJ, Mueller PR. US-guided fine-needle aspiration biopsy of thyroid nodules: adequacy of cytologic material and procedure time with and without immediate cytologic analysis. Radiology. 2002;222:383-387.
    • (2002) Radiology , vol.222 , pp. 383-387
    • O'Malley, M.E.1    Weir, M.M.2    Hahn, P.F.3    Misdraji, J.4    Wood, B.J.5    Mueller, P.R.6
  • 13
    • 0028000984 scopus 로고
    • The role of immediate cytological evaluation in ct-guided biopsy
    • Ward SC, Carey BM, Chalmers AG, Sutton J. The role of immediate cytological evaluation in CT-guided biopsy. Clin Radiol. 1994;49:531-534.
    • (1994) Clin Radiol , vol.49 , pp. 531-534
    • Ward, S.C.1    Carey, B.M.2    Chalmers, A.G.3    Sutton, J.4
  • 14
    • 0027510973 scopus 로고
    • Fine-needle biopsy: Prospective comparison of aspiration versus nonaspiration techniques in the abdomen
    • Kinney TB, Lee MJ, Filomena CA, et al. Fine-needle biopsy: prospective comparison of aspiration versus nonaspiration techniques in the abdomen. Radiology. 1993;186: 549-552.
    • (1993) Radiology , vol.186 , pp. 549-552
    • Kinney, T.B.1    Lee, M.J.2    Filomena, C.A.3
  • 15
    • 0029816001 scopus 로고    scopus 로고
    • Mammographically guided fine-needle aspiration cytology of the breast: Reducing the rate of insufficient specimens
    • Hayes MK, DeBruhl ND, Hirschowitz S, Kimme-Smith C, Bassett LW. Mammographically guided fine-needle aspiration cytology of the breast: reducing the rate of insufficient specimens. AJR Am J Roentgenol. 1996;167:381-384.
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 381-384
    • Hayes, M.K.1    DeBruhl, N.D.2    Hirschowitz, S.3    Kimme-Smith, C.4    Bassett, L.W.5
  • 16
    • 1242351700 scopus 로고    scopus 로고
    • Education and experience improve the performance of transbronchial needle aspiration: A learning curve at a cancer center
    • Hsu LH, Liu CC, Ko JS. Education and experience improve the performance of transbronchial needle aspiration: a learning curve at a cancer center. Chest. 2004;125: 532-540.
    • (2004) Chest , vol.125 , pp. 532-540
    • Hsu, L.H.1    Liu, C.C.2    Ko, J.S.3
  • 17
    • 0020696976 scopus 로고
    • Ct-guided fine-needle aspirations for diagnosis of benign and malignant disease
    • Harter LP, Moss AA, Goldberg HI, Gross BH. CT-guided fine-needle aspirations for diagnosis of benign and malignant disease. AJR Am J Roentgenol. 1983;140: 363-367.
    • (1983) AJR Am J Roentgenol , vol.140 , pp. 363-367
    • Harter, L.P.1    Moss, A.A.2    Goldberg, H.I.3    Gross, B.H.4
  • 18
    • 60849118386 scopus 로고    scopus 로고
    • Does onsite cytotechnology evaluation improve the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsy
    • Alsohaibani F, Girgis S, Sandha GS. Does onsite cytotechnology evaluation improve the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsyCan J Gastroenterol. 2009;23:26-30.
    • (2009) Can J Gastroenterol , vol.23 , pp. 26-30
    • Alsohaibani, F.1    Girgis, S.2    Sandha, G.S.3
  • 19
    • 33644785857 scopus 로고    scopus 로고
    • The impact of assessing specimen adequacy and number of needle passes for fine-needle aspiration biopsy of thyroid nodules
    • Redman R, Zalaznick H, Mazzaferri EL, Massoll NA. The impact of assessing specimen adequacy and number of needle passes for fine-needle aspiration biopsy of thyroid nodules. Thyroid. 2006;16:55-60.
    • (2006) Thyroid , vol.16 , pp. 55-60
    • Redman, R.1    Zalaznick, H.2    Mazzaferri, E.L.3    Massoll, N.A.4
  • 20
    • 0035986965 scopus 로고    scopus 로고
    • Diagnostic value and cost-effectiveness of on-site evaluation of fine-needle aspiration specimens: Review of 5,688 cases
    • Nasuti JF, Gupta PK, Baloch ZW. Diagnostic value and cost-effectiveness of on-site evaluation of fine-needle aspiration specimens: review of 5,688 cases. Diagn Cytopathol. 2002;27:1-4.
    • (2002) Diagn Cytopathol , vol.27 , pp. 1-4
    • Nasuti, J.F.1    Gupta, P.K.2    Baloch, Z.W.3
  • 21
    • 0024408221 scopus 로고
    • Diagnostic accuracy and role of immediate interpretation of fine needle aspiration biopsy specimens from various sites
    • Silverman JF, Finley JL, O'Brien KF, et al. Diagnostic accuracy and role of immediate interpretation of fine needle aspiration biopsy specimens from various sites. Acta Cytol. 1989;33:791-796.
    • (1989) Acta Cytol , vol.33 , pp. 791-796
    • Silverman, J.F.1    Finley, J.L.2    O'Brien, K.F.3
  • 22
    • 57649231014 scopus 로고    scopus 로고
    • Aetiology of non-diagnostic renal fine-needle aspiration cytologies in a contemporary series
    • Andonian S, Okeke Z, VanderBrink BA, et al. Aetiology of non-diagnostic renal fine-needle aspiration cytologies in a contemporary series. BJU Int. 2009;103:28-32.
    • (2009) BJU Int , vol.103 , pp. 28-32
    • Andonian, S.1    Okeke, Z.2    VanderBrink, B.A.3
  • 23
    • 54249167045 scopus 로고    scopus 로고
    • Number of needle passes does not correlate with the diagnostic yield of renal fine needle aspiration cytology
    • Andonian S, Okeke Z, Okeke DA, Sugrue C, Wasserman PG, Lee BR. Number of needle passes does not correlate with the diagnostic yield of renal fine needle aspiration cytology. J Endourol. 2008;22:2377-2380.
    • (2008) J Endourol , vol.22 , pp. 2377-2380
    • Andonian, S.1    Okeke, Z.2    Okeke, D.A.3    Sugrue, C.4    Wasserman, P.G.5    Lee, B.R.6
  • 24
    • 0141989561 scopus 로고    scopus 로고
    • Ct-scan, mri and image-guided fna cytology of incidental adrenal masses
    • Lumachi F, Borsato S, Tregnaghi A, et al. CT-scan, MRI and image-guided FNA cytology of incidental adrenal masses. Eur J Surg Oncol. 2003;29:689-692.
    • (2003) Eur J Surg Oncol , vol.29 , pp. 689-692
    • Lumachi, F.1    Borsato, S.2    Tregnaghi, A.3
  • 25
    • 28444493952 scopus 로고    scopus 로고
    • Role and cost-effectiveness of adrenal imaging and image-guided fna cytology in the management of incidentally discovered adrenal tumours
    • Lumachi F, Basso SM, Borsato S, et al. Role and cost-effectiveness of adrenal imaging and image-guided FNA cytology in the management of incidentally discovered adrenal tumours. Anticancer Res. 2005;25:4559-4562.
    • (2005) Anticancer Res , vol.25 , pp. 4559-4562
    • Lumachi, F.1    Basso, S.M.2    Borsato, S.3
  • 26
    • 34447567226 scopus 로고    scopus 로고
    • High risk of malignancy in patients with incidentally discovered adrenal masses: Accuracy of adrenal imaging and imageguided fine-needle aspiration cytology
    • Lumachi F, Borsato S, Tregnaghi A, et al. High risk of malignancy in patients with incidentally discovered adrenal masses: accuracy of adrenal imaging and imageguided fine-needle aspiration cytology. Tumori. 2007;93: 269-274.
    • (2007) Tumori , vol.93 , pp. 269-274
    • Lumachi, F.1    Borsato, S.2    Tregnaghi, A.3
  • 27
    • 0034034985 scopus 로고    scopus 로고
    • Deep-seated thoracic and abdominal masses: Usefulness of ultrasound and computed tomography guidance in fine needle aspiration cytology diagnosis
    • Sheikh M, Sawhney S, Dey P, al-Saeed O, Behbehani A. Deep-seated thoracic and abdominal masses: usefulness of ultrasound and computed tomography guidance in fine needle aspiration cytology diagnosis. Australas Radiol. 2000;44:155-160.
    • (2000) Australas Radiol , vol.44 , pp. 155-160
    • Sheikh, M.1    Sawhney, S.2    Dey, P.3    Al-Saeed, O.4    Behbehani, A.5
  • 28
    • 2942565825 scopus 로고    scopus 로고
    • Ultrasoundguided fine-needle capillary biopsy of thyroid nodules, coupled with on-site cytologic review, improves results
    • Ceresini G, Corcione L, Morganti S, et al. Ultrasoundguided fine-needle capillary biopsy of thyroid nodules, coupled with on-site cytologic review, improves results. Thyroid. 2004;14:385-389.
    • (2004) Thyroid , vol.14 , pp. 385-389
    • Ceresini, G.1    Corcione, L.2    Morganti, S.3
  • 29
    • 0347761219 scopus 로고    scopus 로고
    • Cost-effectiveness of immediate specimen adequacy assessment of thyroid fine-needle aspirations
    • Eedes CR, Wang HH. Cost-effectiveness of immediate specimen adequacy assessment of thyroid fine-needle aspirations. Am J Clin Pathol. 2004;121:64-69.
    • (2004) Am J Clin Pathol , vol.121 , pp. 64-69
    • Eedes, C.R.1    Wang, H.H.2
  • 30
    • 33644902056 scopus 로고    scopus 로고
    • Specimen adequacy and diagnostic specificity of ultrasound-guided fine needle aspirations of nonpalpable thyroid nodules
    • Kelly NP, Lim JC, DeJong S, Harmath C, Dudiak C, Wojcik EM. Specimen adequacy and diagnostic specificity of ultrasound-guided fine needle aspirations of nonpalpable thyroid nodules. Diagn Cytopathol. 2006;34:188-190.
    • (2006) Diagn Cytopathol , vol.34 , pp. 188-190
    • Kelly, N.P.1    Lim, J.C.2    DeJong, S.3    Harmath, C.4    Dudiak, C.5    Wojcik, E.M.6
  • 31
    • 0033604267 scopus 로고    scopus 로고
    • Ultrasoundguided fine-needle aspiration biopsy of the thyroid
    • Tambouret R, Szyfelbein WM, Pitman MB. Ultrasoundguided fine-needle aspiration biopsy of the thyroid. Cancer. 1999;87:299-305.
    • (1999) Cancer , vol.87 , pp. 299-305
    • Tambouret, R.1    Szyfelbein, W.M.2    Pitman, M.B.3
  • 32
    • 74249085977 scopus 로고    scopus 로고
    • Cytology of endobronchial ultrasound-guided transbronchial needle aspiration: A retrospective study with histology correlation
    • Feller-Kopman D, Yung RC, Burroughs F, Li QK. Cytology of endobronchial ultrasound-guided transbronchial needle aspiration: a retrospective study with histology correlation. Cancer Cytopathol. 2009;117:482-490.
    • (2009) Cancer Cytopathol , vol.117 , pp. 482-490
    • Feller-Kopman, D.1    Yung, R.C.2    Burroughs, F.3    Li, Q.K.4
  • 33
    • 0032762568 scopus 로고    scopus 로고
    • Diagnostic yield of mrguided liver biopsies compared with ct-And us-guided liver biopsies
    • Schmidt AJ, Kee ST, Sze DY, et al. Diagnostic yield of MRguided liver biopsies compared with CT-And US-guided liver biopsies. J Vasc Interv Radiol. 1999;10: 1323-1329.
    • (1999) J Vasc Interv Radiol , vol.10 , pp. 1323-1329
    • Schmidt, A.J.1    Kee, S.T.2    Sze, D.Y.3
  • 34
    • 0035950380 scopus 로고    scopus 로고
    • Immediate on-site interpretation of fine-needle aspiration smears: A cost and compensation analysis
    • Layfield LJ, Bentz JS, Gopez EV. Immediate on-site interpretation of fine-needle aspiration smears: a cost and compensation analysis. Cancer. 2001;93:319-322.
    • (2001) Cancer , vol.93 , pp. 319-322
    • Layfield, L.J.1    Bentz, J.S.2    Gopez, E.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.