메뉴 건너뛰기




Volumn 32, Issue 1-2, 2012, Pages 87-95

Development of australian reference ranges for the left fetal modified myocardial performance index and the influence of caliper location on time interval measurement

Author keywords

Cardiac valve; Doppler; Fetus; Myocardial performance index; Reference range

Indexed keywords

ADULT; AORTA VALVE; ARTICLE; AUSTRALIA; CALIPER PLACEMENT; CARDIOVASCULAR PARAMETERS; DOPPLER ECHOCARDIOGRAPHY; FEMALE; FETUS; FETUS ECHOGRAPHY; FETUS HEART; GESTATIONAL AGE; HEART CONTRACTION; HEART LEFT VENTRICLE EJECTION TIME; HEART PERFORMANCE; HUMAN; INSTRUMENT; ISOVOLUMETRIC CONTRACTION TIME; ISOVOLUMETRIC RELAXATION TIME; LEFT FETAL MODIFIED MYOCARDIAL PERFORMANCE INDEX; LONGITUDINAL STUDY; MAJOR CLINICAL STUDY; MEASUREMENT; MITRAL VALVE; PRIORITY JOURNAL; REFERENCE VALUE; REPRODUCIBILITY; ULTRASOUND SCANNER; VALVE CLICK; WAVEFORM;

EID: 84864887049     PISSN: 10153837     EISSN: 14219964     Source Type: Journal    
DOI: 10.1159/000334133     Document Type: Article
Times cited : (41)

References (29)
  • 1
    • 0035116122 scopus 로고    scopus 로고
    • Quantitative assessment of fetal ventricular function: Establishing normal values of the myocardial performance index in the fetus
    • Eidem BW, Edwards JM, Cetta F: Quantitative assessment of fetal ventricular function: establishing normal values of the myocardial performance index in the fetus. Echocardiography 2001; 18: 9-13.
    • (2001) Echocardiography , vol.18 , pp. 9-13
    • Eidem, B.W.1    Edwards, J.M.2    Cetta, F.3
  • 2
    • 0033456189 scopus 로고    scopus 로고
    • Serial evaluation for myocardial performance in fetuses and neonates using a new Doppler index
    • Tsutsumi T, Ishii M, Eto G, Hota M, Kato H: Serial evaluation for myocardial performance in fetuses and neonates using a new Doppler index. Pediatrics Int 1999; 41:722-727.
    • (1999) Pediatrics Int , vol.41 , pp. 722-727
    • Tsutsumi, T.1    Ishii, M.2    Eto, G.3    Hota, M.4    Kato, H.5
  • 3
    • 0029586902 scopus 로고
    • New index of combined systolic and diastolic myocardial performance: A simple and reproducible measure of cardiac function-a study in normals and dilated cardiomyopa-thy
    • Tei C, Ling LH, Hodge DO, Bailey KR, Oh JK, Rodeheffer RJ, Tajik AJ, Seward JB: New index of combined systolic and diastolic myocardial performance: a simple and reproducible measure of cardiac function-a study in normals and dilated cardiomyopa-thy. J Cardiol 1995; 26: 357-366.
    • (1995) J Cardiol , vol.26 , pp. 357-366
    • Tei, C.1    Ling, L.H.2    Hodge, D.O.3    Bailey, K.R.4    Oh, J.K.5    Rodeheffer, R.J.6    Tajik, A.J.7    Seward, J.B.8
  • 4
    • 0038823750 scopus 로고    scopus 로고
    • Fetal cardiac function assessed by Doppler myocardial performance index (Tei index)
    • Friedman D, Buyon J, Kim M, Glickstein JS: Fetal cardiac function assessed by Doppler myocardial performance index (Tei index). Ultrasound Obst Gynecol 2003; 21:33-36.
    • (2003) Ultrasound Obst Gynecol , vol.21 , pp. 33-36
    • Friedman, D.1    Buyon, J.2    Kim, M.3    Glickstein, J.S.4
  • 6
    • 58149504185 scopus 로고    scopus 로고
    • Modified myocardial performance index for evaluation of fetal cardiac function in pre-eclampsia
    • Api O, Emeksiz MB, Api M, Ugurel V, Unal O, Emeksiz MB: Modified myocardial performance index for evaluation of fetal cardiac function in pre-eclampsia. Ultrasound Obstet Gynecol 2009; 33: 51-57.
    • (2009) Ultrasound Obstet Gynecol , vol.33 , pp. 51-57
    • Api, O.1    Emeksiz, M.B.2    Api, M.3    Ugurel, V.4    Unal, O.5    Emeksiz, M.B.6
  • 9
    • 77954060576 scopus 로고    scopus 로고
    • Usefulness of myocardial tissue Doppler vs convention-alechoca rdiography in the evaluation of cardiac dysfunction in early-onset intrauterine growth restriction
    • Comas M, Crispi F, Cruz-Martinez R, Martinez JM, Figueras F, Gratacos E: Usefulness of myocardial tissue Doppler vs convention-alechoca rdiography in the evaluation of cardiac dysfunction in early-onset intrauterine growth restriction. Am J Obst Gynecol 2010; 203:45.e1-45.e7.
    • (2010) Am J Obst Gynecol , vol.203
    • Comas, M.1    Crispi, F.2    Cruz-Martinez, R.3    Martinez, J.M.4    Figueras, F.5    Gratacos, E.6
  • 13
    • 84859422565 scopus 로고    scopus 로고
    • The fetal left modified myocardial performance index (Mod-MPI): Technical refinements in obtaining the pulsed Doppler waveforms
    • Meriki N, Welsh AW: The fetal left modified myocardial performance index (Mod-MPI): technical refinements in obtaining the pulsed Doppler waveforms. Ultrasound Obstet Gynecol 2012;39:421-429.
    • (2012) Ultrasound Obstet Gynecol , vol.39 , pp. 421-429
    • Meriki, N.1    Welsh, A.W.2
  • 17
    • 78650657886 scopus 로고    scopus 로고
    • Charts to assess fetal wellbe-ing
    • Rasmussen S: Charts to assess fetal wellbe-ing. Ultrasound Obstet Gynecol 2011; 37: 2-5.
    • (2011) Ultrasound Obstet Gynecol , vol.37 , pp. 2-5
    • Rasmussen, S.1
  • 18
    • 33847774040 scopus 로고    scopus 로고
    • A customized birthweight centile calculator developed for an Australian population
    • Mongelli M, Figueras F, Francis A, Gardosi J: A customized birthweight centile calculator developed for an Australian population. Aust NZ J Obstet Gynaecol 2007; 47: 128-131.
    • (2007) Aust NZ J Obstet Gynaecol , vol.47 , pp. 128-131
    • Mongelli, M.1    Figueras, F.2    Francis, A.3    Gardosi, J.4
  • 19
    • 84864869678 scopus 로고    scopus 로고
    • P12.02: Reference ranges for the Mod-MPI (modified myocar-dial performance index) in normal fetuses within an australian population using the previously published technique and a new peak valve click selection technique
    • Meriki N, Welsh AW: P12.02: Reference ranges for the Mod-MPI (modified myocar-dial performance index) in normal fetuses within an australian population using the previously published technique and a new peak valve click selection technique. Ultrasound Obstet Gynecol 2010; 36:212.
    • (2010) Ultrasound Obstet Gynecol , vol.36 , pp. 212
    • Meriki, N.1    Welsh, A.W.2
  • 20
    • 0031906310 scopus 로고    scopus 로고
    • How to construct 'normal ranges' for fetal variables
    • Royston P, Wright EM: How to construct 'normal ranges' for fetal variables. Ultrasound Obstet Gynecol 1998; 11: 30-38.
    • (1998) Ultrasound Obstet Gynecol , vol.11 , pp. 30-38
    • Royston, P.1    Wright, E.M.2
  • 24
    • 27544446093 scopus 로고    scopus 로고
    • Reference ranges for serial measurements of blood velocity and pul-satility index at the intra-abdominal portion, and fetal and placental ends of the umbilical artery
    • Acharya G, Wilsgaard T, Berntsen GK, Mal-tau JM, Kiserud T: Reference ranges for serial measurements of blood velocity and pul-satility index at the intra-abdominal portion, and fetal and placental ends of the umbilical artery. Ultrasound Obstet Gyne-col 2005; 26: 162-169.
    • (2005) Ultrasound Obstet Gyne-col , vol.26 , pp. 162-169
    • Acharya, G.1    Wilsgaard, T.2    Berntsen, G.K.3    Mal-Tau, J.M.4    Kiserud, T.5
  • 25
    • 14644402429 scopus 로고    scopus 로고
    • Reference ranges for serial measurements of umbilical artery Doppler indices in the second half of pregnancy
    • Acharya G, Wilsgaard T, Berntsen GKR, Maltau JM, Kiserud T: Reference ranges for serial measurements of umbilical artery Doppler indices in the second half of pregnancy. Am J Obstet Gynecol 2005; 192:937-944. Kessler J, Rasmussen S, Kiserud T: The left portal vein as an indicator of watershed in the fetal circulation: development during the second half of pregnancy and a suggested method of evaluation. Ultrasound Obstet Gynecol 2007; 30: 757-764.
    • (2005) Am J Obstet Gynecol , vol.192 , pp. 937-944
    • Acharya, G.1    Wilsgaard, T.2    Berntsen, G.K.R.3    Maltau, J.M.4    Kiserud, T.5
  • 26
    • 34748899485 scopus 로고    scopus 로고
    • Middle cerebralartery blood flow velocities and pulsatility index and the cerebroplacental pulsa-tility ratio: Longitudinal reference ranges and terms for serial measurements
    • Ebbing C, Rasmussen S, Kiserud T: Middle cerebralartery blood flow velocities and pulsatility index and the cerebroplacental pulsa-tility ratio: longitudinal reference ranges and terms for serial measurements. Ultrasound Obstet Gynecol 2007; 30:287-296.
    • (2007) Ultrasound Obstet Gynecol , vol.30 , pp. 287-296
    • Ebbing, C.1    Rasmussen, S.2    Kiserud, T.3
  • 27
    • 61849165131 scopus 로고    scopus 로고
    • Fetal superior mesen-teric artery: Longitudinal reference ranges and evidence of regulatory link to portal liver circulation
    • Ebbing C, Rasmussen S, Godfrey KM, Hanson MA, Kiserud T: Fetal superior mesen-teric artery: longitudinal reference ranges and evidence of regulatory link to portal liver circulation. Early Hum Dev 2009; 85:207-213.
    • (2009) Early Hum Dev , vol.85 , pp. 207-213
    • Ebbing, C.1    Rasmussen, S.2    Godfrey, K.M.3    Hanson, M.A.4    Kiserud, T.5
  • 28
    • 55549139822 scopus 로고    scopus 로고
    • Fetal celiac and splenic artery flow velocity and pulsatility index: Longitudinal reference ranges and evidence for vasodilation at a low portocaval pressure gradient
    • Ebbing C, Rasmussen S, Godfrey KM, Hanson MA, Kiserud T: Fetal celiac and splenic artery flow velocity and pulsatility index: longitudinal reference ranges and evidence for vasodilation at a low portocaval pressure gradient. Ultrasound Obstet Gynecol 2008; 32:663-672.
    • (2008) Ultrasound Obstet Gynecol , vol.32 , pp. 663-672
    • Ebbing, C.1    Rasmussen, S.2    Godfrey, K.M.3    Hanson, M.A.4    Kiserud, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.