메뉴 건너뛰기




Volumn , Issue , 2012, Pages 1153-1157

Non-invasive sensing of the electrical energy harvested by medical implants powered by an ultrasonic transcutaneous energy transfer link

Author keywords

[No Author keywords available]

Indexed keywords

AC CURRENTS; ANALYTIC EXPRESSIONS; CLOSED FORM; CONTACTLESS MEASUREMENT; CURRENT SOURCES; EFFECTIVE TOOL; ELECTRICAL ENERGY; EXCITATION FREQUENCY; EXTERNAL COILS; IMPLANTATION DEPTH; IMPLANTED DEVICE; INDUCTIVE LINK; MEASUREMENT ACCURACY; MEDICAL IMPLANTS; NON-INVASIVE SENSING; PEAK VOLTAGE; RESONANCE FREQUENCIES; TRANSCUTANEOUS;

EID: 84864858390     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISIE.2012.6237251     Document Type: Conference Paper
Times cited : (10)

References (15)
  • 2
    • 2342665686 scopus 로고    scopus 로고
    • Implantable glucose sensors for diabetes monitoring
    • April
    • E. Renard, "Implantable glucose sensors for diabetes monitoring," Minim. Invasiv. Ther., vol. 13, no. 2, April 2004, pp. 78-86
    • (2004) Minim. Invasiv. Ther. , vol.13 , Issue.2 , pp. 78-86
    • Renard, E.1
  • 3
    • 0029308898 scopus 로고
    • A continuous, implantable lactate sensor
    • May
    • D. A. Baker and D. A. Gough, "A continuous, implantable lactate sensor," Anal. Chem., vol. 67, no. 9, May 1995, pp. 1536-1540
    • (1995) Anal. Chem. , vol.67 , Issue.9 , pp. 1536-1540
    • Baker, D.A.1    Gough, D.A.2
  • 5
    • 75049084902 scopus 로고    scopus 로고
    • Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
    • October
    • Uei-Ming Jow and Maysam Ghovanloo, "Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments," IEEE Trans. Biomed. Circuits Syst., vol. 3, no. 5, October 2009, pp. 339-347
    • (2009) IEEE Trans. Biomed. Circuits Syst. , vol.3 , Issue.5 , pp. 339-347
    • Jow, U.-M.1    Ghovanloo, M.2
  • 7
    • 77949487799 scopus 로고    scopus 로고
    • Ultrasonic transcutaneous energy transfer for powering implanted devices
    • May
    • S. Ozeri and D. Shmilovitz, "Ultrasonic transcutaneous energy transfer for powering implanted devices", Ultrasonics., vol. 50, no. 6, May 2010, pp. 556-566
    • (2010) Ultrasonics , vol.50 , Issue.6 , pp. 556-566
    • Ozeri, S.1    Shmilovitz, D.2
  • 8
    • 77953256208 scopus 로고    scopus 로고
    • Ultrasonic transcutaneous energy transfer using a continuous wave 650 kHz Gaussian shaded transmitter
    • June
    • S. Ozeri, D. Shmilovitz, S. Singer and C.-C. Wang, "Ultrasonic transcutaneous energy transfer using a continuous wave 650 kHz Gaussian shaded transmitter", Ultrasonics., vol. 50, no. 7, June 2010, pp. 666-674
    • (2010) Ultrasonics , vol.50 , Issue.7 , pp. 666-674
    • Ozeri, S.1    Shmilovitz, D.2    Singer, S.3    Wang, C.-C.4
  • 9
    • 50149109666 scopus 로고    scopus 로고
    • Wireless powering of implanted sensors using rf inductive coupling
    • October
    • K. Fotopoulou and B. W. Flynn, "Wireless Powering of Implanted Sensors using RF Inductive Coupling," 5th IEEE Conference on Sensors, October 2006, pp. 765-768
    • (2006) 5th IEEE Conference on Sensors , pp. 765-768
    • Fotopoulou, K.1    Flynn, B.W.2
  • 10
    • 34247889987 scopus 로고    scopus 로고
    • Feedback analysis and design of RF power links for low-power bionic system
    • March
    • M. W. Baker and R. Sarpeshkar, "Feedback analysis and design of RF power links for low-power bionic system", IEEE Trans. Biomed. Circuits Syst., vol. 1, no. 1, March 2007, pp. 28-38
    • (2007) IEEE Trans. Biomed. Circuits Syst. , vol.1 , Issue.1 , pp. 28-38
    • Baker, M.W.1    Sarpeshkar, R.2
  • 11
    • 0014972416 scopus 로고
    • Beam behavior within the nearfield of a vibrating piston
    • J. Zemanek, "Beam behavior within the nearfield of a vibrating piston", J. Acoust. Soc. Am., vol. 49, 1971, pp. 181-191
    • (1971) J. Acoust. Soc. Am. , vol.49 , pp. 181-191
    • Zemanek, J.1
  • 12
    • 77949489559 scopus 로고    scopus 로고
    • John Wiley Pub., pp. 130-134
    • D. T. Blackstock, "Physical acoustics", John Wiley Pub., 2000, pp.39- 44, pp. 130-134.
    • (2000) Physical Acoustics , pp. 39-44
    • Blackstock, D.T.1
  • 14
    • 0003412981 scopus 로고
    • 2nd ed., G. P. Harnwell (ed.) New York: McGraw-Hill Book Company Inc.
    • W. R. Smythe, "Static and dynamic electricity", 2nd ed., G. P. Harnwell (ed.), New York: McGraw-Hill Book Company Inc., 1950
    • (1950) Static and Dynamic Electricity
    • Smythe, W.R.1
  • 15
    • 3242658213 scopus 로고    scopus 로고
    • Design of coils for millimeter and sub millimeter sized biotelemetry
    • S. F. Pichorim and P. J. Abatti, "Design of coils for millimeter and sub millimeter sized biotelemetry," IEEE Trans. Biomed. Eng., vol. 51, No. 8, 2004, pp. 1487-1489
    • (2004) IEEE Trans. Biomed. Eng. , vol.51 , Issue.8 , pp. 1487-1489
    • Pichorim, S.F.1    Abatti, P.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.