메뉴 건너뛰기




Volumn , Issue , 2012, Pages 796-799

Generic rebooting scheme and model-based probabilistic pruning algorithm for tree-like structure tracking

Author keywords

early termination; leaking control; model based pruning; probabilistic tracking; vessel segmentation

Indexed keywords

CARDIAC-COMPUTED TOMOGRAPHY; CORONARY ARTERIES; EARLY TERMINATION; HUMAN SUBJECTS; IMAGE ARTIFACTS; MODEL-BASED PRUNING; PRUNING ALGORITHMS; TRACKING ALGORITHM; TREE-LIKE STRUCTURES; VESSEL SEGMENTATION; VESSEL STRUCTURE;

EID: 84864846507     PISSN: 19457928     EISSN: 19458452     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2012.6235668     Document Type: Conference Paper
Times cited : (5)

References (10)
  • 1
    • 0028259857 scopus 로고
    • 3D imaging of blood vessels using X-ray rotational angiographic system
    • N. Niki, Y. Kawata, H. Satoh, and T. Kumazaki, "3D imaging of blood vessels using X-ray rotational angiographic system," in NSS/MIC, 1993, vol. 3.
    • (1993) NSS/MIC , vol.3
    • Niki, N.1    Kawata, Y.2    Satoh, H.3    Kumazaki, T.4
  • 2
    • 0036489383 scopus 로고    scopus 로고
    • An X-ray-based method for the determination of the contrast agent propagation in 3-D vessel structures
    • march
    • H. Schmitt, M. Grass, V. Rasche, O. Schramm, S. Haehnel, and K. Sartor, "An X-ray-based method for the determination of the contrast agent propagation in 3-D vessel structures," IEEE Trans. Med. Imag., vol. 21, no. 3, march 2002.
    • (2002) IEEE Trans. Med. Imag , vol.21 , Issue.3
    • Schmitt, H.1    Grass, M.2    Rasche, V.3    Schramm, O.4    Haehnel, S.5    Sartor, K.6
  • 3
    • 0028397144 scopus 로고
    • A 3D reconstruction of vascular structures from two X-ray angiograms using an adapted simulated annealing algorithm
    • mar
    • C. Pellot, A. Herment, M. Sigelle, P. Horain, H. Maitre, and P. Peronneau, "A 3D reconstruction of vascular structures from two X-ray angiograms using an adapted simulated annealing algorithm," IEEE Trans. Med. Imag., vol. 13, no. 1, mar 1994.
    • (1994) IEEE Trans. Med. Imag , vol.13 , Issue.1
    • Pellot, C.1    Herment, A.2    Sigelle, M.3    Horain, P.4    Maitre, H.5    Peronneau, P.6
  • 4
    • 0032034235 scopus 로고    scopus 로고
    • A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering
    • april
    • Y.A. Tolias and S.M. Panas, "A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering," IEEE Trans. Med. Imag., vol. 17, no. 2, april 1998.
    • (1998) IEEE Trans. Med. Imag , vol.17 , Issue.2
    • Tolias, Y.A.1    Panas, S.M.2
  • 5
    • 84942568837 scopus 로고    scopus 로고
    • Vessel extraction techniques and algorithms: A survey
    • C. Kirbas and F.K.H. Quek, "Vessel extraction techniques and algorithms: a survey," in BIBE, 2003.
    • (2003) BIBE
    • Kirbas, C.1    Quek, F.K.H.2
  • 6
    • 0002544197 scopus 로고    scopus 로고
    • Vascular shape segmentation and structure extraction using a shapebased region-growing model
    • Y. Masutani, T. Schiemann, and K.H. Höhne, "Vascular shape segmentation and structure extraction using a shapebased region-growing model," in MICCAI, 1998.
    • (1998) MICCAI
    • Masutani, Y.1    Schiemann, T.2    Höhne, K.H.3
  • 7
    • 29144514433 scopus 로고    scopus 로고
    • Intrathoracic airway trees: Segmentation and airway morphology analysis from low-dose CT scans
    • dec.
    • J. Tschirren, E.A. Hoffman, G. McLennan, and M. Sonka, "Intrathoracic airway trees: segmentation and airway morphology analysis from low-dose CT scans," IEEE Trans. Med. Imag., vol. 24, no. 12, dec. 2005.
    • (2005) IEEE Trans. Med. Imag , vol.24 , Issue.12
    • Tschirren, J.1    Hoffman, E.A.2    McLennan, G.3    Sonka, M.4
  • 8
    • 80055035224 scopus 로고    scopus 로고
    • Coronary artery tree tracking with robust junction detection in 3D CT angiography
    • Fei Zhao and R. Bhotika, "Coronary artery tree tracking with robust junction detection in 3D CT angiography," in ISBI, 2011.
    • (2011) ISBI
    • Zhao, F.1    Bhotika, R.2
  • 10
    • 68949196294 scopus 로고    scopus 로고
    • Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms
    • M. Schaap et al., "Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms," Med. Imag. Ana., vol. 13/5, 2009.
    • (2009) Med. Imag. Ana , vol.13 , Issue.5
    • Schaap, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.