메뉴 건너뛰기




Volumn , Issue , 2012, Pages 618-621

3D reconstruction of coronary arteries from rotational X-ray angiography

Author keywords

3D reconstruction; 3DCA; coronary arteries; projections; skeletons; X ray angiography

Indexed keywords

3D RECONSTRUCTION; 3DCA; CORONARY ARTERIES; PROJECTIONS; SKELETONS; X RAY ANGIOGRAPHY;

EID: 84864830014     PISSN: 19457928     EISSN: 19458452     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2012.6235624     Document Type: Conference Paper
Times cited : (18)

References (7)
  • 1
    • 77956111528 scopus 로고    scopus 로고
    • Quantification of lumen stenoses with known dimensions by conventional angiography and CT? implications for the use of angiography as a gold standard
    • A. Arbab-Zadeh, J. Texter, and K. Ostbye, "Quantification of lumen stenoses with known dimensions by conventional angiography and CT? implications for the use of angiography as a gold standard," Heart, vol. 96, pp. 1358-1363, 2010.
    • (2010) Heart , vol.96 , pp. 1358-1363
    • Arbab-Zadeh, A.1    Texter, J.2    Ostbye, K.3
  • 2
    • 33646420868 scopus 로고    scopus 로고
    • Reconstruction of coronary arteries from a single rotational X-ray projection sequence
    • C. Blondel, G. Malandain, R. Vaillant, and N. Ayache, "Reconstruction of coronary arteries from a single rotational X-ray projection sequence," Trans. Med. Imaging., vol. 25, no. 5, pp. 653-663, 2006.
    • (2006) Trans. Med. Imaging. , vol.25 , Issue.5 , pp. 653-663
    • Blondel, C.1    Malandain, G.2    Vaillant, R.3    Ayache, N.4
  • 3
    • 54949154867 scopus 로고    scopus 로고
    • Evaluation of iterative sparse object reconstruction from few projections for 3-D rotational coronary angiography
    • E. Hansis, D. Schafer, O. Dossel, and M. Grass, "Evaluation of iterative sparse object reconstruction from few projections for 3-D rotational coronary angiography," Trans. Med. Imaging., vol. 27, no. 11, pp. 1548-1555, 2008.
    • (2008) Trans. Med. Imaging. , vol.27 , Issue.11 , pp. 1548-1555
    • Hansis, E.1    Schafer, D.2    Dossel, O.3    Grass, M.4
  • 4
    • 3342925349 scopus 로고    scopus 로고
    • Improved iterative algorithm for sparse object reconstruction and its performance evaluation with micro-CT data
    • M. Li, H. Kudo, J. Hu, and R. H. Johnson, "Improved iterative algorithm for sparse object reconstruction and its performance evaluation with micro-CT data," IEEE Trans. Nucl. Sci., vol. 51, no. 3, pp. 659-666, 2004.
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , Issue.3 , pp. 659-666
    • Li, M.1    Kudo, H.2    Hu, J.3    Johnson, R.H.4
  • 5
    • 70350304823 scopus 로고    scopus 로고
    • Automatic generation of 3D coronary artery centerlines using rotational X-ray angiography
    • U. Jandt, D. Schfer,M. Grass, and V. Rasche, "Automatic generation of 3D coronary artery centerlines using rotational X-ray angiography," Med. Imag. Anal., vol. 13, no. 6, pp. 846-858, 2009.
    • (2009) Med. Imag. Anal. , vol.13 , Issue.6 , pp. 846-858
    • Jandt, U.1    Schferm. Grass, D.2    Rasche, V.3
  • 6
    • 67649872377 scopus 로고    scopus 로고
    • Novel approach for 3-D reconstruction of coronary arteries from 2 uncalibrated angiographic images
    • J. Yang, Y. Wang, Y. Liu, S. Tang, and W. Chen, "Novel approach for 3-D reconstruction of coronary arteries from 2 uncalibrated angiographic images," Trans. image. processing., vol. 18, no. 7, pp. 1563-1572, 2009.
    • (2009) Trans. Image. Processing. , vol.18 , Issue.7 , pp. 1563-1572
    • Yang, J.1    Wang, Y.2    Liu, Y.3    Tang, S.4    Chen, W.5
  • 7
    • 65549089797 scopus 로고    scopus 로고
    • Multiscale vessel enhancement filtering
    • W.M. Wells, A. Colchester and S.L. Delp (eds.), MICCAI' 98, Berlin, Germany
    • A.F. Frangi, W.J. Niessen, and M.A. Viergever K.L. Vincken, "Multiscale vessel enhancement filtering," in W.M. Wells, A. Colchester and S.L. Delp (eds.), MICCAI' 98, LNCS, Berlin, Germany, 1998, vol. 1496, pp. 130-137.
    • (1998) LNCS , vol.1496 , pp. 130-137
    • Frangi, A.F.1    Niessen, W.J.2    Viergever, M.A.3    Vincken, K.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.