메뉴 건너뛰기




Volumn 35, Issue 8, 2012, Pages 1021-1034

Catheter ablation utilizing remote magnetic navigation: A review of applications and outcomes

Author keywords

ablation; clinical trials; data analysis; electrophysiology clinical

Indexed keywords

CARDIOVASCULAR MAGNETIC RESONANCE; CARDIOVASCULAR RISK; CATHETER ABLATION; CLINICAL PRACTICE; CONGENITAL HEART DISEASE; DEFIBRILLATOR; ELECTROGRAPHY; EPICARDIUM; FLUOROSCOPY; FOLLOW UP; HEART ARRHYTHMIA; HEART ATRIUM FIBRILLATION; HEART ATRIUM FLUTTER; HEART CATHETER; HEART DISEASE; HEART ELECTROPHYSIOLOGY; HEART LEFT VENTRICLE OUTFLOW TRACT; HEART MUSCLE; HEART MUSCLE CONDUCTION SYSTEM; HEART RIGHT VENTRICLE OUTFLOW TRACT; HEART VENTRICLE EXTRASYSTOLE; HEART VENTRICLE TACHYCARDIA; HUMAN; MAGNETIC FIELD; MAGNETIC NAVIGATION SYSTEM; PATIENT SAFETY; PULMONARY VEIN; RADIATION EXPOSURE; REENTRY TACHYCARDIA; REVIEW; SUPRAVENTRICULAR TACHYCARDIA; TECHNOLOGY; TREATMENT CONTRAINDICATION; TREATMENT OUTCOME;

EID: 84864709466     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2012.03382.x     Document Type: Review
Times cited : (64)

References (41)
  • 1
    • 12144289547 scopus 로고    scopus 로고
    • Initial experience with remote catheter ablation using a novel magnetic navigation system: Magnetic remote catheter ablation
    • Ernst S, Ouyang F, Linder C, Hertting K, Stahl F, Chun J, Hachiya H, et al,. Initial experience with remote catheter ablation using a novel magnetic navigation system: magnetic remote catheter ablation. Circulation. 2004; 109: 1472-1475.
    • (2004) Circulation. , vol.109 , pp. 1472-1475
    • Ernst, S.1    Ouyang, F.2    Linder, C.3    Hertting, K.4    Stahl, F.5    Chun, J.6    Hachiya, H.7
  • 2
    • 33745197531 scopus 로고    scopus 로고
    • Magnetic navigation in AV nodal re-entrant tachycardia study: Early results of ablation with one- and three-magnet catheters
    • Thornton AS, Janse P, Theuns DA, Scholten MF, Jordaens LJ,. Magnetic navigation in AV nodal re-entrant tachycardia study: Early results of ablation with one- and three-magnet catheters. Europace 2006; 8: 225-230.
    • (2006) Europace , vol.8 , pp. 225-230
    • Thornton, A.S.1    Janse, P.2    Theuns, D.A.3    Scholten, M.F.4    Jordaens, L.J.5
  • 3
    • 33244464984 scopus 로고    scopus 로고
    • Radiofrequency ablation of atrioventricular nodal reentrant tachycardia using a novel magnetic guidance system compared with a conventional approach
    • Kerzner R, Sanchez JM, Osborn JL, Chen J, Faddis MN, Gleva MJ, Lindsay BD, et al,. Radiofrequency ablation of atrioventricular nodal reentrant tachycardia using a novel magnetic guidance system compared with a conventional approach. Heart Rhythm 2006; 3: 261-267.
    • (2006) Heart Rhythm , vol.3 , pp. 261-267
    • Kerzner, R.1    Sanchez, J.M.2    Osborn, J.L.3    Chen, J.4    Faddis, M.N.5    Gleva, M.J.6    Lindsay, B.D.7
  • 4
    • 51849140575 scopus 로고    scopus 로고
    • Remote magnetic versus manual catheter navigation for ablation of supraventricular tachycardias: A randomized, multicenter trial
    • Wood MA, Orlov M, Ramaswamy K, Haffajee C, Ellenbogen K,. Remote magnetic versus manual catheter navigation for ablation of supraventricular tachycardias: A randomized, multicenter trial. Pacing Clin Electrophysiol 2008; 31: 1313-1321.
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1313-1321
    • Wood, M.A.1    Orlov, M.2    Ramaswamy, K.3    Haffajee, C.4    Ellenbogen, K.5
  • 5
    • 68749102048 scopus 로고    scopus 로고
    • Initial clinical experience of remote magnetic navigation system for catheter mapping and ablation of supraventricular tachycardias
    • Xu D, Yang B, Shan Q, Zou J, Chen M, Chen C, Hou X, et al,. Initial clinical experience of remote magnetic navigation system for catheter mapping and ablation of supraventricular tachycardias. J Interv Card Electrophysiol 2009; 25: 171-174.
    • (2009) J Interv Card Electrophysiol , vol.25 , pp. 171-174
    • Xu, D.1    Yang, B.2    Shan, Q.3    Zou, J.4    Chen, M.5    Chen, C.6    Hou, X.7
  • 7
    • 79959754847 scopus 로고    scopus 로고
    • The magnetic navigation system allows safety and high efficacy for ablation of arrhythmias
    • Bauernfeind T, Akca F, Schwagten B, de Groot N, Van Belle Y, Valk S, Ujvari B, et al,. The magnetic navigation system allows safety and high efficacy for ablation of arrhythmias. Europace 2011; 13: 1015-1021.
    • (2011) Europace , vol.13 , pp. 1015-1021
    • Bauernfeind, T.1    Akca, F.2    Schwagten, B.3    De Groot, N.4    Van Belle, Y.5    Valk, S.6    Ujvari, B.7
  • 8
    • 33847011342 scopus 로고    scopus 로고
    • Remote-controlled catheter ablation of accessory pathways: Results from the magnetic laboratory
    • Chun JK, Ernst S, Matthews S, Schmidt B, Bansch D, Boczor S, Ujeyl A, et al,. Remote-controlled catheter ablation of accessory pathways: Results from the magnetic laboratory. Eur Heart J 2007; 28: 190-195.
    • (2007) Eur Heart J , vol.28 , pp. 190-195
    • Chun, J.K.1    Ernst, S.2    Matthews, S.3    Schmidt, B.4    Bansch, D.5    Boczor, S.6    Ujeyl, A.7
  • 9
    • 34247502871 scopus 로고    scopus 로고
    • Magnetic navigation in left-sided AV reentrant tachycardias: Preliminary results of a retrograde approach
    • Thornton AS, Rivero-Ayerza M, Knops P, Jordaens LJ,. Magnetic navigation in left-sided AV reentrant tachycardias: Preliminary results of a retrograde approach. J Cardiovasc Electrophysiol 2007; 18: 467-472.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 467-472
    • Thornton, A.S.1    Rivero-Ayerza, M.2    Knops, P.3    Jordaens, L.J.4
  • 11
    • 42649135860 scopus 로고    scopus 로고
    • Initial clinical experience with a remote magnetic catheter navigation system for ablation of cavotricuspid isthmus-dependent right atrial flutter
    • Arya A, Kottkamp H, Piorkowski C, Bollmann A, Gerdes-Li JH, Riahi S, Esato M, et al,. Initial clinical experience with a remote magnetic catheter navigation system for ablation of cavotricuspid isthmus-dependent right atrial flutter. Pacing Clin Electrophysiol 2008; 31: 597-603.
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 597-603
    • Arya, A.1    Kottkamp, H.2    Piorkowski, C.3    Bollmann, A.4    Gerdes-Li, J.H.5    Riahi, S.6    Esato, M.7
  • 12
    • 73949093115 scopus 로고    scopus 로고
    • Remote magnetic catheter navigation for cavotricuspid isthmus ablation in patients with common-type atrial flutter
    • Vollmann D, Luthje L, Seegers J, Hasenfuss G, Zabel M,. Remote magnetic catheter navigation for cavotricuspid isthmus ablation in patients with common-type atrial flutter. Circ Arrhythm Electrophysiol 2009; 2: 603-610.
    • (2009) Circ Arrhythm Electrophysiol , vol.2 , pp. 603-610
    • Vollmann, D.1    Luthje, L.2    Seegers, J.3    Hasenfuss, G.4    Zabel, M.5
  • 19
    • 78650812213 scopus 로고    scopus 로고
    • Atrial fibrillation ablation: A single center comparison between remote magnetic navigation, cryoballoon and conventional manual pulmonary vein isolation
    • Sorgente A, Chierchia GB, Capulzini L, Yazaki Y, Muller-Burri A, Bayrak F, Sarkozy A, et al,. Atrial fibrillation ablation: A single center comparison between remote magnetic navigation, cryoballoon and conventional manual pulmonary vein isolation. Indian Pacing Electrophysiol J 2010; 10: 486-495.
    • (2010) Indian Pacing Electrophysiol J , vol.10 , pp. 486-495
    • Sorgente, A.1    Chierchia, G.B.2    Capulzini, L.3    Yazaki, Y.4    Muller-Burri, A.5    Bayrak, F.6    Sarkozy, A.7
  • 21
    • 78650448364 scopus 로고    scopus 로고
    • Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: A case-control study
    • Arya A, Zaker-Shahrak R, Sommer P, Bollmann A, Wetzel U, Gaspar T, Richter S, et al,. Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: A case-control study. Europace 2011; 13: 45-50.
    • (2011) Europace , vol.13 , pp. 45-50
    • Arya, A.1    Zaker-Shahrak, R.2    Sommer, P.3    Bollmann, A.4    Wetzel, U.5    Gaspar, T.6    Richter, S.7
  • 22
    • 70349298685 scopus 로고    scopus 로고
    • Usefulness of remote magnetic navigation for ablation of ventricular arrhythmias originating from outflow regions
    • Schwagten BK, Szili-Torok T, Rivero-Ayerza M, Jessurun E, Valk S, Jordaens LJ,. Usefulness of remote magnetic navigation for ablation of ventricular arrhythmias originating from outflow regions. Neth Heart J 2009; 17: 245-249.
    • (2009) Neth Heart J , vol.17 , pp. 245-249
    • Schwagten, B.K.1    Szili-Torok, T.2    Rivero-Ayerza, M.3    Jessurun, E.4    Valk, S.5    Jordaens, L.J.6
  • 23
    • 33646786800 scopus 로고    scopus 로고
    • Remote magnetic navigation for mapping and ablating right ventricular outflow tract tachycardia
    • Thornton AS, Jordaens LJ,. Remote magnetic navigation for mapping and ablating right ventricular outflow tract tachycardia. Heart Rhythm 2006; 3: 691-696.
    • (2006) Heart Rhythm , vol.3 , pp. 691-696
    • Thornton, A.S.1    Jordaens, L.J.2
  • 25
    • 79955400144 scopus 로고    scopus 로고
    • Catheter ablation of right ventricular outflow tract tachycardia: A simplified remote-controlled approach
    • Konstantinidou M, Koektuerk B, Wissner E, Schmidt B, Zerm T, Ouyang F, Kuck KH, et al,. Catheter ablation of right ventricular outflow tract tachycardia: A simplified remote-controlled approach. Europace 2011; 13: 696-700.
    • (2011) Europace , vol.13 , pp. 696-700
    • Konstantinidou, M.1    Koektuerk, B.2    Wissner, E.3    Schmidt, B.4    Zerm, T.5    Ouyang, F.6    Kuck, K.H.7
  • 26
    • 77956861454 scopus 로고    scopus 로고
    • Endo-epicardial ablation of ventricular arrhythmias in the left ventricle with the Remote Magnetic Navigation System and the 3.5-mm open irrigated magnetic catheter: Results from a large single-center case-control series
    • Di Biase L, Santangeli P, Astudillo V, Conti S, Mohanty P, Mohanty S, Sanchez JE, et al,. Endo-epicardial ablation of ventricular arrhythmias in the left ventricle with the Remote Magnetic Navigation System and the 3.5-mm open irrigated magnetic catheter: Results from a large single-center case-control series. Heart Rhythm 2010; 7: 1029-1035.
    • (2010) Heart Rhythm , vol.7 , pp. 1029-1035
    • Di Biase, L.1    Santangeli, P.2    Astudillo, V.3    Conti, S.4    Mohanty, P.5    Mohanty, S.6    Sanchez, J.E.7
  • 27
    • 33947732778 scopus 로고    scopus 로고
    • Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia
    • Aryana A, d'Avila A, Heist EK, Mela T, Singh JP, Ruskin JN, Reddy VY,. Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia. Circulation 2007; 115: 1191-1200.
    • (2007) Circulation , vol.115 , pp. 1191-1200
    • Aryana, A.1    D'Avila, A.2    Heist, E.K.3    Mela, T.4    Singh, J.P.5    Ruskin, J.N.6    Reddy, V.Y.7
  • 28
    • 67650404069 scopus 로고    scopus 로고
    • Initial clinical experience with the new irrigated tip magnetic catheter for ablation of scar-related sustained ventricular tachycardia: A small case series
    • Haghjoo M, Hindricks G, Bode K, Piorkowski C, Bollmann A, Arya A,. Initial clinical experience with the new irrigated tip magnetic catheter for ablation of scar-related sustained ventricular tachycardia: A small case series. J Cardiovasc Electrophysiol 2009; 20: 935-939.
    • (2009) J Cardiovasc Electrophysiol , vol.20 , pp. 935-939
    • Haghjoo, M.1    Hindricks, G.2    Bode, K.3    Piorkowski, C.4    Bollmann, A.5    Arya, A.6
  • 29
    • 78349250567 scopus 로고    scopus 로고
    • Catheter ablation of scar-related ventricular tachycardia in patients with electrical storm using remote magnetic catheter navigation
    • Arya A, Eitel C, Bollmann A, Wetzel U, Sommer P, Gaspar T, Husser D, et al,. Catheter ablation of scar-related ventricular tachycardia in patients with electrical storm using remote magnetic catheter navigation. Pacing Clin Electrophysiol 2010; 33: 1312-1318.
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 1312-1318
    • Arya, A.1    Eitel, C.2    Bollmann, A.3    Wetzel, U.4    Sommer, P.5    Gaspar, T.6    Husser, D.7
  • 30
    • 58249143480 scopus 로고    scopus 로고
    • Irrigated radiofrequency catheter ablation guided by electroanatomic mapping for recurrent ventricular tachycardia after myocardial infarction: The multicenter thermocool ventricular tachycardia ablation trial
    • Stevenson WG, Wilber DJ, Natale A, Jackman WM, Marchlinski FE, Talbert T, Gonzalez MD, et al,. Irrigated radiofrequency catheter ablation guided by electroanatomic mapping for recurrent ventricular tachycardia after myocardial infarction: The multicenter thermocool ventricular tachycardia ablation trial. Circulation 2008; 118: 2773-2782.
    • (2008) Circulation , vol.118 , pp. 2773-2782
    • Stevenson, W.G.1    Wilber, D.J.2    Natale, A.3    Jackman, W.M.4    Marchlinski, F.E.5    Talbert, T.6    Gonzalez, M.D.7
  • 31
    • 72949105566 scopus 로고    scopus 로고
    • Catheter ablation of recurrent scar-related ventricular tachycardia using electroanatomical mapping and irrigated ablation technology: Results of the prospective multicenter Euro-VT-study
    • Tanner H, Hindricks G, Volkmer M, Furniss S, Kuhlkamp V, Lacroix D, DEC C, et al,. Catheter ablation of recurrent scar-related ventricular tachycardia using electroanatomical mapping and irrigated ablation technology: Results of the prospective multicenter Euro-VT-study. J Cardiovasc Electrophysiol 2010; 21: 47-53.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 47-53
    • Tanner, H.1    Hindricks, G.2    Volkmer, M.3    Furniss, S.4    Kuhlkamp, V.5    Lacroix, D.6    Dec, C.7
  • 32
    • 55449089147 scopus 로고    scopus 로고
    • Mapping of intraatrial reentrant tachycardias by remote magnetic navigation in patients with d-transposition of the great arteries after mustard or senning procedure
    • Wu J, Pflaumer A, Deisenhofer I, Ucer E, Hess J, Zrenner B, Hessling G,. Mapping of intraatrial reentrant tachycardias by remote magnetic navigation in patients with d-transposition of the great arteries after mustard or senning procedure. J Cardiovasc Electrophysiol 2008; 19: 1153-1159.
    • (2008) J Cardiovasc Electrophysiol , vol.19 , pp. 1153-1159
    • Wu, J.1    Pflaumer, A.2    Deisenhofer, I.3    Ucer, E.4    Hess, J.5    Zrenner, B.6    Hessling, G.7
  • 33
    • 77954036453 scopus 로고    scopus 로고
    • Mapping of atrial tachycardia by remote magnetic navigation in postoperative patients with congenital heart disease
    • Wu J, Pflaumer A, Deisenhofer I, Hoppmann P, Hess J, Hessling G,. Mapping of atrial tachycardia by remote magnetic navigation in postoperative patients with congenital heart disease. J Cardiovasc Electrophysiol 2008; 21: 751-759.
    • (2008) J Cardiovasc Electrophysiol , vol.21 , pp. 751-759
    • Wu, J.1    Pflaumer, A.2    Deisenhofer, I.3    Hoppmann, P.4    Hess, J.5    Hessling, G.6
  • 37
    • 78049500222 scopus 로고    scopus 로고
    • Safety of implantable pacemakers and cardioverter defibrillators in the magnetic field of a novel remote magnetic navigation system
    • Jilek C, Tzeis S, Reents T, Estner HL, Fichtner S, Ammar S, Wu J, et al., Safety of implantable pacemakers and cardioverter defibrillators in the magnetic field of a novel remote magnetic navigation system. J Cardiovasc Electrophysiol 2010; 21: 1136-1141.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 1136-1141
    • Jilek, C.1    Tzeis, S.2    Reents, T.3    Estner, H.L.4    Fichtner, S.5    Ammar, S.6    Wu, J.7
  • 39
    • 80053531595 scopus 로고    scopus 로고
    • A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices
    • Nazarian S, Hansford R, Roguin A, Goldsher D, Zviman MM, Lardo AC, Caffo BS, et al,. A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices. Ann Intern Med 2011; 155: 415-424.
    • (2011) Ann Intern Med , vol.155 , pp. 415-424
    • Nazarian, S.1    Hansford, R.2    Roguin, A.3    Goldsher, D.4    Zviman, M.M.5    Lardo, A.C.6    Caffo, B.S.7
  • 40


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.