Volumn 81, Issue 9, 2012, Pages 2231-2245

3 T MR tomography of the brachial plexus: Structural and microstructural evaluation

Author keywords

Brachial plexus; DTI; Magnetic resonance neurography; STIR; Tractography

Indexed keywords

AXONAL INJURY; BRACHIAL PLEXUS; BRACHIAL PLEXUS INJURY; BRACHIAL PLEXUS NEUROPATHY; CLINICAL PRACTICE; DIFFUSION TENSOR IMAGING; DIFFUSION WEIGHTED IMAGING; FOLLOW UP; FRACTIONAL ANISOTROPY; HUMAN; IMAGE PROCESSING; MAGNETIC FIELD; MYELOGRAPHY; NERVE DEGENERATION; NERVE FUNCTION; NEURILEMOMA; NEUROGRAPHY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIMARY TUMOR; PRIORITY JOURNAL; REVIEW; STEADY STATE; THORAX OUTLET SYNDROME; THREE DIMENSIONAL IMAGING; TRAFFIC ACCIDENT; WHITE MATTER; ARTICLE; HISTOLOGY; IMAGE ENHANCEMENT; METHODOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 84864696070     PISSN: 0720048X     EISSN: 18727727     Source Type: Journal    
DOI: 10.1016/j.ejrad.2011.05.021     Document Type: Review
Times cited : (54)

References (21)
  • 2
    • 76149111940 scopus 로고    scopus 로고
    • Magnetic resonance neurography for the evaluation of peripheral nerve, brachial plexus, and nerve root disorders
    • R. Du, K.I. Auguste, C.T. Chin, J.W. Engstrom, and P.R. Weinstein Magnetic resonance neurography for the evaluation of peripheral nerve, brachial plexus, and nerve root disorders J Neurosurg 112 2010 362 371
    • (2010) J Neurosurg , vol.112 , pp. 362-371
    • Du, R.1    Auguste, K.I.2    Chin, C.T.3    Engstrom, J.W.4    Weinstein, P.R.5
  • 5
    • 52049090805 scopus 로고    scopus 로고
    • High-resolution and functional magnetic resonance imaging of the brachial plexus using an isotropic 3D T2 STIR (Short Term Inversion Recovery) SPACE sequence and diffusion tensor imaging
    • M. Viallon, M.I. Vargas, H. Jlassi, K.O. Lovblad, and J. Delavelle High-resolution and functional magnetic resonance imaging of the brachial plexus using an isotropic 3D T2 STIR (Short Term Inversion Recovery) SPACE sequence and diffusion tensor imaging Eur Radiol 18 2008 1018 1023
    • (2008) Eur Radiol , vol.18 , pp. 1018-1023
    • Viallon, M.1    Vargas, M.I.2    Jlassi, H.3    Lovblad, K.O.4    Delavelle, J.5
  • 6
    • 79953812455 scopus 로고    scopus 로고
    • Subtraction of unidirectionally encoded images for suppression of heavily isotropic objects (SUSHI) for selective visualization of peripheral nerves
    • T. Takahara, T.C. Kwee, and J. Hendrikse Subtraction of unidirectionally encoded images for suppression of heavily isotropic objects (SUSHI) for selective visualization of peripheral nerves Neuroradiology 2010
    • (2010) Neuroradiology
    • Takahara, T.1    Kwee, T.C.2    Hendrikse, J.3
  • 7
    • 77953934203 scopus 로고    scopus 로고
    • Neuroanatomy of the brachial plexus: Normal and variant anatomy of its formation
    • E.O. Johnson, M. Vekris, T. Demesticha, and P.N. Soucacos Neuroanatomy of the brachial plexus: normal and variant anatomy of its formation Surg Radiol Anat 32 2010 291 297
    • (2010) Surg Radiol Anat , vol.32 , pp. 291-297
    • Johnson, E.O.1    Vekris, M.2    Demesticha, T.3    Soucacos, P.N.4
  • 8
    • 10744225741 scopus 로고    scopus 로고
    • Implications of SENSE MR in routine clinical practice
    • J.S. van den Brink, Y. Watanabe, and C.K. Kuhl Implications of SENSE MR in routine clinical practice Eur J Radiol 46 2003 3 27
    • (2003) Eur J Radiol , vol.46 , pp. 3-27
    • Van Den Brink, J.S.1    Watanabe, Y.2    Kuhl, C.K.3
  • 9
    • 84864715400 scopus 로고    scopus 로고
    • MR imaging of the brachial plexus: Comparison between 1.5-T and 3-T MR imaging: Preliminary experience
    • A. Tagliafico, G. Succio, and C. Emanuele Neumaier MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience Skeletal Radiol 2010
    • (2010) Skeletal Radiol
    • Tagliafico, A.1    Succio, G.2    Emanuele Neumaier, C.3
  • 10
    • 49049096893 scopus 로고    scopus 로고
    • Segmented echo planar MR imaging of the brachial plexus with inversion recovery magnetization preparation at 3.0 T
    • Z. Zhang, L. Song, and Q. Meng Segmented echo planar MR imaging of the brachial plexus with inversion recovery magnetization preparation at 3.0 T J Magn Reson Imaging 28 2008 440 444
    • (2008) J Magn Reson Imaging , vol.28 , pp. 440-444
    • Zhang, Z.1    Song, L.2    Meng, Q.3
  • 11
    • 34948897576 scopus 로고    scopus 로고
    • Body MR imaging at 3.0 T: Understanding the opportunities and challenges
    • discussion 62-4
    • M.M. Barth, M.P. Smith, I. Pedrosa, R.E. Lenkinski, and N.M. Rofsky Body MR imaging at 3.0 T: understanding the opportunities and challenges Radiographics 27 2007 1445 1462 discussion 62-4
    • (2007) Radiographics , vol.27 , pp. 1445-1462
    • Barth, M.M.1    Smith, M.P.2    Pedrosa, I.3    Lenkinski, R.E.4    Rofsky, N.M.5
  • 12
    • 31144462324 scopus 로고    scopus 로고
    • Diffusion-tensor fiber tractography: Intraindividual comparison of 3.0-T and 1.5-T MR imaging
    • T. Okada, Y. Miki, and Y. Fushimi Diffusion-tensor fiber tractography: intraindividual comparison of 3.0-T and 1.5-T MR imaging Radiology 238 2006 668 678
    • (2006) Radiology , vol.238 , pp. 668-678
    • Okada, T.1    Miki, Y.2    Fushimi, Y.3
  • 14
    • 0022969218 scopus 로고
    • MR imaging of intravoxel incoherent motions: Application to diffusion and perfusion in neurologic disorders
    • D. Le Bihan, E. Breton, D. Lallemand, P. Grenier, E. Cabanis, and M. Laval-Jeantet MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders Radiology 161 1986 401 407
    • (1986) Radiology , vol.161 , pp. 401-407
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3    Grenier, P.4    Cabanis, E.5    Laval-Jeantet, M.6
  • 15
    • 0028398052 scopus 로고
    • Estimation of the effective self-diffusion tensor from the NMR spin echo
    • P.J. Basser, J. Mattiello, and D. LeBihan Estimation of the effective self-diffusion tensor from the NMR spin echo J Magn Reson B 103 1994 247 254
    • (1994) J Magn Reson B , vol.103 , pp. 247-254
    • Basser, P.J.1    Mattiello, J.2    Lebihan, D.3
  • 16
    • 74749085422 scopus 로고    scopus 로고
    • Evaluation of diffusion tensor imaging and fiber tractography of the median nerve: Preliminary results on intrasubject variability and precision of measurements
    • G. Andreisek, L.M. White, A. Kassner, and M.S. Sussman Evaluation of diffusion tensor imaging and fiber tractography of the median nerve: preliminary results on intrasubject variability and precision of measurements AJR Am J Roentgenol 194 2010 W65 W72
    • (2010) AJR Am J Roentgenol , vol.194
    • Andreisek, G.1    White, L.M.2    Kassner, A.3    Sussman, M.S.4
  • 17
    • 77949261441 scopus 로고    scopus 로고
    • Diffusion tensor imaging (DTI) and tractography of the brachial plexus: Feasibility and initial experience in neoplastic conditions
    • M.I. Vargas, M. Viallon, D. Nguyen, J. Delavelle, and M. Becker Diffusion tensor imaging (DTI) and tractography of the brachial plexus: feasibility and initial experience in neoplastic conditions Neuroradiology 52 2010 237 245
    • (2010) Neuroradiology , vol.52 , pp. 237-245
    • Vargas, M.I.1    Viallon, M.2    Nguyen, D.3    Delavelle, J.4    Becker, M.5
  • 19
    • 79951944116 scopus 로고    scopus 로고
    • Diffusion tensor imaging and fibre tracking in cervical spondylotic myelopathy
    • J.F. Budzik, V. Balbi, V. Le Thuc, A. Duhamel, R. Assaker, and A. Cotten Diffusion tensor imaging and fibre tracking in cervical spondylotic myelopathy Eur Radiol 21 2011 426 433
    • (2011) Eur Radiol , vol.21 , pp. 426-433
    • Budzik, J.F.1    Balbi, V.2    Le Thuc, V.3    Duhamel, A.4    Assaker, R.5    Cotten, A.6
  • 21
    • 79952269369 scopus 로고    scopus 로고
    • In vivo assessment of peripheral nerve regeneration by diffusion tensor imaging
    • S. Morisaki, Y. Kawai, and M. Umeda In vivo assessment of peripheral nerve regeneration by diffusion tensor imaging J Magn Reson Imaging 2011
    • (2011) J Magn Reson Imaging
    • Morisaki, S.1    Kawai, Y.2    Umeda, M.3