메뉴 건너뛰기




Volumn 15, Issue 8, 2012, Pages 825-833

Development of new spacer device geometry: A CFD study (Part I)

Author keywords

CFD; design; Fluent ; spacer

Indexed keywords

BOUNDARY LAYER DEVELOPMENT; COMPUTATIONAL FLUID DYNAMICS ANALYSIS; DEVICE GEOMETRIES; MEDICAL DEVICES; METERED-DOSE INHALERS; OPTIMISATIONS; RECIRCULATION ZONES; SPACER; TRANSIENT AIRFLOW;

EID: 84864682314     PISSN: 10255842     EISSN: 14768259     Source Type: Journal    
DOI: 10.1080/10255842.2011.563359     Document Type: Article
Times cited : (20)

References (26)
  • 4
    • 0032958579 scopus 로고    scopus 로고
    • A comparative analysis of the particle size output of beclomethasone diproprionate, salmeterol xinafoate and fluticasone proprionate metered dose inhalers used with the Babyhler, Volumatic and Aerochamber spacer devices
    • Barry, PW and O'Callaghan, C. 1999a. A comparative analysis of the particle size output of beclomethasone diproprionate, salmeterol xinafoate and fluticasone proprionate metered dose inhalers used with the Babyhler, Volumatic and Aerochamber spacer devices. J Clin Pharmacol, 47: 357-360.
    • (1999) J Clin Pharmacol , vol.47 , pp. 357-360
    • Barry, P.W.1    O'Callaghan, C.2
  • 5
    • 0033452863 scopus 로고    scopus 로고
    • The output of budesonide from spacer devices assessed under simulated breathing conditions
    • Barry, PW and O'Callaghan, C. 1999b. The output of budesonide from spacer devices assessed under simulated breathing conditions. J Allergy Clin Immunol, 104(6): 1205-1210.
    • (1999) J Allergy Clin Immunol , vol.104 , Issue.6 , pp. 1205-1210
    • Barry, P.W.1    O'Callaghan, C.2
  • 6
    • 33751327296 scopus 로고    scopus 로고
    • A brief history of inhaled asthma therapy over the last fifty years
    • Crompton, G. 2006. A brief history of inhaled asthma therapy over the last fifty years. Prim Care Respir J, 15: 326-331.
    • (2006) Prim Care Respir J , vol.15 , pp. 326-331
    • Crompton, G.1
  • 8
    • 13544258981 scopus 로고    scopus 로고
    • In my opinion: interview with the expert
    • Dolovich, MB. 2004. In my opinion: interview with the expert. Pediatr Asthma Allergy Immunol, 17(4): 292-300.
    • (2004) Pediatr Asthma Allergy Immunol , vol.17 , Issue.4 , pp. 292-300
    • Dolovich, M.B.1
  • 10
    • 33645007599 scopus 로고    scopus 로고
    • FLUENT Lebanon, NH: Fluent Inc
    • FLUENT. 2004. GAMBIT 2.2 User's Guide, Lebanon, NH: Fluent Inc.
    • (2004) GAMBIT 2.2 User's Guide
  • 11
    • 59749104715 scopus 로고    scopus 로고
    • FLUENT Lebanon, NH: Fluent Inc
    • FLUENT. 2006a. FLUENT 6.3 UDF Manual, Lebanon, NH: Fluent Inc.
    • (2006) FLUENT 6.3 UDF Manual
  • 12
    • 33846055582 scopus 로고    scopus 로고
    • FLUENT Lebanon, NH: Fluent Inc
    • FLUENT. 2006b. FLUENT 6.3 User's Guide, Lebanon, NH: Fluent Inc.
    • (2006) FLUENT 6.3 User's Guide
  • 14
    • 84864708100 scopus 로고    scopus 로고
    • Lisboa: QuidNovi
    • Marques, JA. 2007. Asma, Lisboa: QuidNovi.
    • (2007) Asma
    • Marques, J.A.1
  • 15
    • 84864709139 scopus 로고    scopus 로고
    • Nelson essential of pediatrics
    • PA: Elsevier Saunders 133 Assesment, Section XVIII The respiratory system
    • Marshall, SG and Debley, JS. 2006. "Nelson essential of pediatrics". PA: Elsevier Saunders. 133 Assesment, Section XVIII The respiratory system
    • (2006)
    • Marshall, S.G.1    Debley, J.S.2
  • 17
    • 2342667615 scopus 로고    scopus 로고
    • Spacers devices for metered dose inhalers
    • Newman, SP. 2004. Spacers devices for metered dose inhalers. Clin Pharmacokinet, 43(6): 349-360.
    • (2004) Clin Pharmacokinet , vol.43 , Issue.6 , pp. 349-360
    • Newman, S.P.1
  • 18
    • 84864721341 scopus 로고    scopus 로고
    • Encyclopedia of respiratory medicine
    • Nottingham (UK): Elsevier
    • Newman, SP. 2006. "Encyclopedia of respiratory medicine". In Aerosol, 58-64. Nottingham (UK): Elsevier.
    • (2006) Aerosol , pp. 58-64
    • Newman, S.P.1
  • 20
    • 0026320776 scopus 로고
    • Effect of a volumatic spacer and mouth rinsing on systemic absorption of inhaled corticosteroids from a metered dose inhaler and dry powder inhaler
    • Selroos, O and Halme, M. 1991. Effect of a volumatic spacer and mouth rinsing on systemic absorption of inhaled corticosteroids from a metered dose inhaler and dry powder inhaler. Thorax, 46(12): 891-894.
    • (1991) Thorax , vol.46 , Issue.12 , pp. 891-894
    • Selroos, O.1    Halme, M.2
  • 21
    • 0031945816 scopus 로고    scopus 로고
    • New devices for asthma
    • Tashkin, DP. 1998. New devices for asthma. J Allergy Clin Immunol, 101(2): S409-S416.
    • (1998) J Allergy Clin Immunol , vol.101 , Issue.2
    • Tashkin, D.P.1
  • 22
    • 0034776471 scopus 로고    scopus 로고
    • Pressurized metered dose inhalers and add-on devices
    • Terzano, C. 2001. Pressurized metered dose inhalers and add-on devices. Pulm Pharmacol Ther, 14(5): 351-366.
    • (2001) Pulm Pharmacol Ther , vol.14 , Issue.5 , pp. 351-366
    • Terzano, C.1
  • 24
    • 11144333703 scopus 로고    scopus 로고
    • Clinical evaluation of the peak inspiratory flow generated by asthmatic children through the Novolizer
    • Vogelberg, C, Kremer, HJ, Ellers-Lenz, B, Engel, M, Maus, J, Conred, F and Hermann, R. 2003. Clinical evaluation of the peak inspiratory flow generated by asthmatic children through the Novolizer. Respir Med, 98: 924-931.
    • (2003) Respir Med , vol.98 , pp. 924-931
    • Vogelberg, C.1    Kremer, H.J.2    Ellers-Lenz, B.3    Engel, M.4    Maus, J.5    Conred, F.6    Hermann, R.7
  • 25


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.