-
1
-
-
0037403120
-
Linear accelerator-based stereotactic radiosurgery for limited, locally persistent, and recurrent nasopharyngeal carcinoma: Efficacy and complications
-
DOI 10.1016/S0360-3016(03)00074-9
-
D. T. Chua, J. S. Sham, P. W. Kwong, K. N. Hung, and L. H. Leung, Linear accelerator-based stereotactic radiosurgery for limited, locally persistent, and recurrent nasopharyngeal carcinoma: Efficacy and complications., Int. J. Radiat. Oncol. Biol. Phys. 56, 177-183 (2003). 10.1016/S0360-3016(03)00074-9 (Pubitemid 36403689)
-
(2003)
International Journal of Radiation Oncology Biology Physics
, vol.56
, Issue.1
, pp. 177-183
-
-
Chua, D.T.T.1
Sham, J.S.T.2
Kwong, P.W.K.3
Hung, K.-N.4
Leung, L.H.T.5
-
2
-
-
34548663661
-
Outcome of Fractionated Stereotactic Radiotherapy for 90 Patients With Locally Persistent and Recurrent Nasopharyngeal Carcinoma
-
DOI 10.1016/j.ijrobp.2007.03.037, PII S0360301607005561
-
S. X. Wu, D. Chua, M. L. Deng, C. Zhao, F. Y. Li, J. Sham, H. Wang, Y. Bao, Y. Gao, and Z. Zeng, Outcome of fractionated stereotactic radiotherapy for 90 patients with locally persistent and recurrent nasopharyngeal carcinoma., Int. J. Radiat. Oncol. Biol. Phys. 69, 761-769 (2007). 10.1016/j.ijrobp.2007.03. 037 (Pubitemid 47418385)
-
(2007)
International Journal of Radiation Oncology Biology Physics
, vol.69
, Issue.3
, pp. 761-769
-
-
Wu, S.-X.1
Chua, D.T.T.2
Deng, M.-L.3
Zhao, C.4
Li, F.-Y.5
Sham, J.S.T.6
Wang, H.-Y.7
Bao, Y.8
Gao, Y.-H.9
Zeng, Z.-F.10
-
3
-
-
43049173297
-
Excellent local control with stereotactic radiotherapy boost after external beam radiotherapy in patients with nasopharyngeal carcinoma
-
10.1016/j.ijrob2007.10.027
-
W. Hara, B. Loo, D. Goffinet, S. Chang, J. Adler, H. Pinto, W. Fee, M. Kaplan, N. Fischbein, and Q. Le, Excellent local control with stereotactic radiotherapy boost after external beam radiotherapy in patients with nasopharyngeal carcinoma., Int. J. Radiat. Oncol. Biol. Phys. 71, 393-400 (2008). 10.1016/j.ijrobp.2007.10.027
-
(2008)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.71
, pp. 393-400
-
-
Hara, W.1
Loo, B.2
Goffinet, D.3
Chang, S.4
Adler, J.5
Pinto, H.6
Fee, W.7
Kaplan, M.8
Fischbein, N.9
Le, Q.10
-
4
-
-
78650033891
-
Dosimetric comparison of intensity-modulated stereotactic radiotherapy with other stereotactic techniques for locally recurrent nasopharyngeal carcinoma
-
10.1016/j.ijrob2009.10.044
-
W. S. Kung, W. C. Wu, K. M. Kam, S. F. Leung, K. H. Yu, Y. K. Ngai, C. F. Wong, and T. K. Chan, Dosimetric comparison of intensity-modulated stereotactic radiotherapy with other stereotactic techniques for locally recurrent nasopharyngeal carcinoma., Int. J. Radiat. Oncol. Biol. Phys. 79, 71-79 (2011). 10.1016/j.ijrobp.2009.10.044
-
(2011)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.79
, pp. 71-79
-
-
Kung, W.S.1
Wu, W.C.2
Kam, K.M.3
Leung, S.F.4
Yu, K.H.5
Ngai, Y.K.6
Wong, C.F.7
Chan, T.K.8
-
5
-
-
0343602910
-
The impact of electron transport on the accuracy of computed dose
-
DOI 10.1118/1.599004
-
M. Arnfield, C. Siantar, J. Siebers, P. Garmon, L. Cox, and R. Mohan, The impact of electron transport on the accuracy of computed dose., Med. Phys. 27, 1266-1273 (2000). 10.1118/1.599004 (Pubitemid 30416094)
-
(2000)
Medical Physics
, vol.27
, Issue.6
, pp. 1266-1274
-
-
Arnfield, M.R.1
Hartmann Siantar, C.2
Siebers, J.3
Garmon, P.4
Cox, L.5
Mohan, R.6
-
6
-
-
47649106110
-
A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media
-
DOI 10.1088/0031-9155/53/14/008, PII S0031915508770039
-
L. Tillikainen, H. Helminen, T. Torsti, S. Siljamaki, J. Alakuijala, J. Pyyry, and W. Ulmer, A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media., Phys. Med. Biol. 53, 3821-3839 (2008). 10.1088/0031-9155/53/14/008 (Pubitemid 352020269)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.14
, pp. 3821-3839
-
-
Tillikainen, L.1
Helminen, H.2
Torsti, T.3
Siljamaki, S.4
Alakuijala, J.5
Pyyry, J.6
Ulmer, W.7
-
7
-
-
79551659612
-
The accuracy of dose calculations by anisotropic analytical algorithms for stereotactic radiotherapy in nasopharyngeal carcinoma
-
10.1088/0031-9155/56/2/008
-
W. K. Kan, Y. C. Cheung, H. T. Leung, M. F. Lau, and K. N. Yu, The accuracy of dose calculations by anisotropic analytical algorithms for stereotactic radiotherapy in nasopharyngeal carcinoma., Phys. Med. Biol. 56, 397-413 (2011). 10.1088/0031-9155/56/2/008
-
(2011)
Phys. Med. Biol.
, vol.56
, pp. 397-413
-
-
Kan, W.K.1
Cheung, Y.C.2
Leung, H.T.3
Lau, M.F.4
Yu, K.N.5
-
8
-
-
74549169230
-
Validation of a new grid based Boltzmann equation solver for dose calculation in radiotherapy with photon beams
-
10.1088/0031-9155/55/3/002
-
O. N. Vassiliev, T. Wareing, J. McGhee, G. Failla, M. Salehpour, and F. Mourtada, Validation of a new grid based Boltzmann equation solver for dose calculation in radiotherapy with photon beams., Phys. Med. Biol. 55, 581-598 (2010). 10.1088/0031-9155/55/3/002
-
(2010)
Phys. Med. Biol.
, vol.55
, pp. 581-598
-
-
Vassiliev, O.N.1
Wareing, T.2
McGhee, J.3
Failla, G.4
Salehpour, M.5
Mourtada, F.6
-
9
-
-
79952919293
-
Dosimetric validation of the Acuros XB advanced dose calculation algorithm: Fundamental characterization in water
-
10.1088/0031-9155/56/6/022
-
A. Fogliata, G. Nicolini, A. Clivio, E. Vanetti, P. Mancosu, and L. Cozzi, Dosimetric validation of the Acuros XB advanced dose calculation algorithm: Fundamental characterization in water., Phys. Med. Biol. 56, 1879-1904 (2011). 10.1088/0031-9155/56/6/022
-
(2011)
Phys. Med. Biol.
, vol.56
, pp. 1879-1904
-
-
Fogliata, A.1
Nicolini, G.2
Clivio, A.3
Vanetti, E.4
Mancosu, P.5
Cozzi, L.6
-
10
-
-
0034036210
-
Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations
-
DOI 10.1088/0031-9155/45/4/313, PII S0031915500090473
-
V. Siebers, P. J. Keall, A. E. Nahum, and R. Mohan, Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations., Phys. Med. Biol. 45, 983-995 (2000). 10.1088/0031-9155/45/4/313 (Pubitemid 30196390)
-
(2000)
Physics in Medicine and Biology
, vol.45
, Issue.4
, pp. 983-995
-
-
Siebers, J.V.1
Keall, P.J.2
Nahum, A.E.3
Mohan, R.4
-
11
-
-
80855156794
-
Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc stereotactic treatments
-
10.1118/1.3654739
-
A. Fogliata, G. Nicolini, A. Clivio, E. Vanetti, and L. Cozzi, Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc stereotactic treatments., Med. Phys. 38, 6228-6237 (2011). 10.1118/1.3654739
-
(2011)
Med. Phys.
, vol.38
, pp. 6228-6237
-
-
Fogliata, A.1
Nicolini, G.2
Clivio, A.3
Vanetti, E.4
Cozzi, L.5
-
12
-
-
79960554736
-
Dosimetric evaluation of Acuros XB advanced dose calculation algorithm in heterogeneous media
-
10.1186/1748-717X-6-82
-
A. Fogliata, G. Nicolini, A. Clivio, E. Vanetti, and L. Cozzi, Dosimetric evaluation of Acuros XB advanced dose calculation algorithm in heterogeneous media., Radiat. Oncol. 6, 82 (2011). 10.1186/1748-717X-6-82
-
(2011)
Radiat. Oncol.
, vol.6
, pp. 82
-
-
Fogliata, A.1
Nicolini, G.2
Clivio, A.3
Vanetti, E.4
Cozzi, L.5
-
13
-
-
79953648704
-
Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations
-
10.1118/1.3567146
-
K. Bush, I. M. Gagne, S. Zavgorodni, W. Ansbacher, and W. Beckham, Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations., Med. Phys. 38, 2208-2221 (2011). 10.1118/1.3567146
-
(2011)
Med. Phys.
, vol.38
, pp. 2208-2221
-
-
Bush, K.1
Gagne, I.M.2
Zavgorodni, S.3
Ansbacher, W.4
Beckham, W.5
-
14
-
-
79961059930
-
Impact of the calculation resolution of AAA for small fields and RapisArc treatment plans
-
10.1118/1.3605468
-
C. L. Ong, J. P. Cuijpers, S. Senan, B. J. Slotman, and W. Verbakel, Impact of the calculation resolution of AAA for small fields and RapisArc treatment plans., Med. Phys. 38, 4471-4478 (2011). 10.1118/1.3605468
-
(2011)
Med. Phys.
, vol.38
, pp. 4471-4478
-
-
Ong, C.L.1
Cuijpers, J.P.2
Senan, S.3
Slotman, B.J.4
Verbakel, W.5
-
15
-
-
0342617576
-
A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate
-
DOI 10.1016/S0360-3016(96)00601-3, PII S0360301696006013
-
A. vant Riet, A. C. Mak, M. A. Moerland, L. H. Elders, and W. van der Zee, A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate.. Int. J. Radiat. Oncol. Bio. Phys. 37, 731-736 (1997). 10.1016/S0360-3016(96)00601-3 (Pubitemid 27175329)
-
(1997)
International Journal of Radiation Oncology Biology Physics
, vol.37
, Issue.3
, pp. 731-736
-
-
Riet, A.V.1
Mak, A.C.A.2
Moerland, M.A.3
Elders, L.H.4
Van Der Zee, W.5
-
16
-
-
84863630399
-
Critical appraisal of Acuros XB and anisotropic analytic algorithm dose calculation in advanced non-small-cell lung cancer treatments
-
10.1016/j.ijrob2011.10.078
-
A. Fogliata, G. Nicolini, A. Clivio, E. Vanetti, and L. Cozzi, Critical appraisal of Acuros XB and anisotropic analytic algorithm dose calculation in advanced non-small-cell lung cancer treatments., Int. J. Radiat. Oncol. Biol. Phys. 83, 1587-1595 (2012). 10.1016/j.ijrobp.2011.10.078
-
(2012)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.83
, pp. 1587-1595
-
-
Fogliata, A.1
Nicolini, G.2
Clivio, A.3
Vanetti, E.4
Cozzi, L.5
-
17
-
-
80052026114
-
On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment
-
10.1186/1748-717X-6-103
-
A. Fogliata, G. Nicolini, A. Clivio, E. Vanetti, and L. Cozzi, On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment., Radiat. Oncol. 6, 103 (2011). 10.1186/1748-717X-6-103
-
(2011)
Radiat. Oncol.
, vol.6
, pp. 103
-
-
Fogliata, A.1
Nicolini, G.2
Clivio, A.3
Vanetti, E.4
Cozzi, L.5
|