메뉴 건너뛰기




Volumn 27, Issue 3, 2012, Pages 799-806

Stator flux active damping methods for field-oriented doubly fed induction generator

Author keywords

Doubly fed induction generator (DFIG); flux stabilization; induction generator

Indexed keywords

ACTIVE DAMPING; BANDWIDTH CONTROL; DAMPING SYSTEM; DOUBLY FED INDUCTION GENERATOR (DFIG); DOUBLY FED INDUCTION GENERATORS; EXPERIMENTAL VERIFICATION; ROTOR CURRENT; ROTOR CURRENT CONTROLLER; STATOR FLUX; STATOR-FLUX ORIENTATION; STEADY STATE; SYSTEM VARIABLES; UNSTABLE REGIONS;

EID: 84864618220     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2012.2204887     Document Type: Article
Times cited : (33)

References (23)
  • 2
    • 0030146394 scopus 로고    scopus 로고
    • Doubly fed induction generator using back-to-back PWM converters and its application to variablespeed wind-energy generation
    • R. Pena, J. C. Clare, and G. M. Asher, "Doubly fed induction generator using back-To-back PWM converters and its application to variable-speed wind-energy generation," in Proc. Inst. Elect. Eng., May 1996, vol. 143, pp. 231-241. (Pubitemid 126760209)
    • (1996) IEE Proceedings: Electric Power Applications , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 4
    • 0035330905 scopus 로고    scopus 로고
    • Direct power control of grid-connected wound rotor induction machine without rotor position sensors
    • DOI 10.1109/63.923772, PII S0885899301040352
    • R. Datta and V. T. Ranganathan, "Direct power control of grid-connected wound rotor induction machine without rotor position sensors," IEEE Trans. Power Electron., vol. 16, no. 3, pp. 390-399, May 2001. (Pubitemid 32534596)
    • (2001) IEEE Transactions on Power Electronics , vol.16 , Issue.3 , pp. 390-399
    • Datta, R.1    Ranganathan, V.T.2
  • 5
    • 1542267195 scopus 로고    scopus 로고
    • Stability analysis of doubly-fed induction machines in stator flux reference frame
    • H. Heller and W. Schumacher, "Stability analysis of doubly-fed induction machines in stator flux reference frame," in Proc. Eur. Conf. Power Electron. Appl., 1997, pp. 2. 707-2. 710.
    • (1997) Proc. Eur. Conf. Power Electron. Appl. , pp. 2707-2710
    • Heller, H.1    Schumacher, W.2
  • 7
    • 12744262671 scopus 로고    scopus 로고
    • Evaluation of current control methods for wind turbines using doubly-fed induction machines
    • DOI 10.1109/TPEL.2004.839785
    • A. Petersson, L. Harnefors, and T. Thiringer, "Evaluation of current control methods for wind turbines using doubly-fed induction machines," IEEE Trans. Power Electron., vol. 20, no. 1, pp. 227-235, Jan. 2005. (Pubitemid 40154864)
    • (2005) IEEE Transactions on Power Electronics , vol.20 , Issue.1 , pp. 227-235
    • Petersson, A.1    Harnefors, L.2    Thiringer, T.3
  • 8
    • 29244448716 scopus 로고    scopus 로고
    • Modeling and experimental verification of grid interaction of a DFIG wind turbine
    • DOI 10.1109/TEC.2005.853750
    • A. Petersson, T. Thiringer, L. Hartfors, and T. Petru, "Modeling and experimental verification of grid interaction of a DFIG wind turbine," IEEE Trans. Energy Convers., vol. 20, no. 4, pp. 878-886, Dec. 2005. (Pubitemid 41830065)
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.4 , pp. 878-886
    • Petersson, A.1    Thiringer, T.2    Harnefors, L.3    Petru, T.4
  • 9
    • 33847733894 scopus 로고    scopus 로고
    • Dynamic behavior of the doubly-fed induction generator in stator flux vector reference frame
    • DOI 10.1109/PESC.2005.1581923, 1581923, 36th IEEE Power Electronics Specialists Conference 2005
    • J. Marques and H. Pinheiro, "Dynamic behavior of the doubly-fed induction generator in stator flux vector reference frame," in Proc. IEEE 36th Conf. Power Electron. Spec., Jun. 2005, pp. 2104-2110. (Pubitemid 46379468)
    • (2005) PESC Record - IEEE Annual Power Electronics Specialists Conference , vol.2005 , pp. 2104-2110
    • Marques, J.1    Pinheiro, H.2
  • 10
    • 63149091048 scopus 로고    scopus 로고
    • Stability analysis of doubly-fed induction wind generator operation at low power factor mode
    • Nov.
    • Y. Zheng, Y. Li, and J. Chai, "Stability analysis of doubly-fed induction wind generator operation at low power factor mode," in Proc. 34th IEEE Annu. Conf. Ind. Electron., Nov. 2008, pp. 2241-2246.
    • (2008) Proc. 34th IEEE Annu. Conf. Ind. Electron. , pp. 2241-2246
    • Zheng, Y.1    Li, Y.2    Chai, J.3
  • 11
    • 78751503815 scopus 로고    scopus 로고
    • Steady state characteristic analysis and stability assessment of doubly fed induction generator based wind power generation system
    • Y. Zhang, J. Jia, W. Li, D. Wang, and J. Liu, "Steady state characteristic analysis and stability assessment of doubly fed induction generator based wind power generation system," in Proc. Int. Conf. Power Syst. Technol., 2010, pp. 1-5.
    • (2010) Proc. Int. Conf. Power Syst. Technol. , pp. 1-5
    • Zhang, Y.1    Jia, J.2    Li, W.3    Wang, D.4    Liu, J.5
  • 12
    • 63149164061 scopus 로고    scopus 로고
    • Amortecimento activo do fluxo em máquinas trifásicas de dupla alimentaç ao controladas pelas correntes rotóricas
    • Jun.
    • C. R. Kelber and W. Schumacher, "Amortecimento activo do fluxo em máquinas trifásicas de dupla alimentaç ao controladas pelas correntes rotóricas," Electrón. de Potência, vol. 8, no. 1, pp. 33-41, Jun. 2003.
    • (2003) Electrón. de Potência , vol.8 , Issue.1 , pp. 33-41
    • Kelber, C.R.1    Schumacher, W.2
  • 13
    • 44449175025 scopus 로고    scopus 로고
    • Active damping of flux oscillations in doubly-fed ac machines using dynamic variations of the system's structure
    • M. C. R. Kelber andW. Schumacher, "Active damping of flux oscillations in doubly-fed AC machines using dynamic variations of the system's structure," in Proc. Eur. Conf. Power Electron. Appl., 2001, pp. P1-P8.
    • (2001) Proc. Eur. Conf. Power Electron. Appl.
    • Kelber, M.C.R.1    Schumacher, W.2
  • 16
    • 70349616083 scopus 로고    scopus 로고
    • Ride through of wind turbines with boubly fed induction generator under symmetrical voltage dips
    • Oct.
    • J. Lopez, E. Gubia, E. Olea, L. Ruiz, and L. Marroyo, "Ride through of wind turbines with boubly fed induction generator under symmetrical voltage dips," IEEE Trans. Ind. Electron., vol. 56, no. 10, pp. 4246-4254, Oct. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.10 , pp. 4246-4254
    • Lopez, J.1    Gubia, E.2    Olea, E.3    Ruiz, L.4    Marroyo, L.5
  • 17
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • DOI 10.1109/TEC.2006.875783
    • D. Xiang, L. Ran, P. Tavner, and S. Yang, "Control of a doubly fed induction generator in a wind turbine during grid fault ride-Through," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 652-662, Sep. 2006. (Pubitemid 46445154)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 652-662
    • Xiang, D.1    Ran, L.2    Tavner, P.J.3    Yang, S.4
  • 18
    • 82755172962 scopus 로고    scopus 로고
    • Active stabilization method for the doubly-fed induction generator using a quadrature inner control loop
    • Setúbal, Portugal
    • G. D. Marques, "Active stabilization method for the doubly-fed induction generator using a quadrature inner control loop," in Proc. Int. Conf. Power Eng. Energy Electr. Drives, Setúbal, Portugal, 2007, pp. 765-768.
    • (2007) Proc. Int. Conf. Power Eng. Energy Electr. Drives , pp. 765-768
    • Marques, G.D.1
  • 19
    • 57849157531 scopus 로고    scopus 로고
    • Analysis of a dq stator flux stabilization method for the doubly-fed induction generator
    • Cambridge, U.K., Jun./Jul.
    • G. D. Marques, "Analysis of a dq stator flux stabilization method for the doubly-fed induction generator," in Proc. Int. Symp. Ind. Electron., Cambridge, U.K., Jun./Jul. 2008, pp. 2475-2480.
    • (2008) Proc. Int. Symp. Ind. Electron. , pp. 2475-2480
    • Marques, G.D.1
  • 20
    • 67650651257 scopus 로고    scopus 로고
    • Modeling and stability analysis of a dfig-based wind-power generator interfaced with a series-compensated line
    • Jul.
    • A. Ostadi, A. Yazdani, and R. Varma, "Modeling and stability analysis of a DFIG-based wind-power generator interfaced with a series-compensated line," IEEE Trans. Power Delivery, vol. 24, no. 3, pp. 1504-1514, Jul. 2009.
    • (2009) IEEE Trans. Power Delivery , vol.24 , Issue.3 , pp. 1504-1514
    • Ostadi, A.1    Yazdani, A.2    Varma, R.3
  • 21
    • 20544446440 scopus 로고    scopus 로고
    • Doubly fed induction generator model for transient stability analysis
    • DOI 10.1109/TEC.2005.845523
    • P. Ledesma and J. Usaola, "Doubly fed induction generator model for transient stability analysis," IEEE Trans. Energy Convers., vol. 20, no. 2, pp. 388-397, Jun. 2005. (Pubitemid 40843740)
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.2 , pp. 388-397
    • Ledesma, P.1    Usaola, J.2
  • 22
    • 84857753334 scopus 로고    scopus 로고
    • Stator flux dampingmethods of the field oriented doublyfed induction generator
    • presented at the, Lisbon, Portugal
    • G. D. Marques, "Stator flux dampingmethods of the field oriented doublyfed induction generator," presented at the Conf. Electr. Power Quality Utilization, Lisbon, Portugal, 2011.
    • (2011) Conf. Electr. Power Quality Utilization
    • Marques, G.D.1
  • 23
    • 84861455831 scopus 로고    scopus 로고
    • Understanding the doubly fed induction generator during voltage dips
    • Jun.
    • G. D. Marques and D. M. Sousa, "Understanding the doubly fed induction generator during voltage dips," IEEE Trans. Energy Convers., vol. 27, no. 2, pp. 421-431, Jun. 2012.
    • (2012) IEEE Trans. Energy Convers. , vol.27 , Issue.2 , pp. 421-431
    • Marques, G.D.1    Sousa, D.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.