메뉴 건너뛰기




Volumn , Issue , 2011, Pages 6651-6654

Automated high-performance cIMT measurement techniques using patented AtheroEdge™: A screening and home monitoring system

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATIC ALGORITHMS; BIOMEDICAL TECHNOLOGIES; CARDIOVASCULAR RISK; CAROTID ARTERY; DISTANCE METRICS; HIGH-PERFORMANCE TECHNIQUES; HOME MONITORING SYSTEMS; INTIMA-MEDIA THICKNESS; MEASUREMENT TECHNIQUES; REMOTE MONITORING; SEGMENTATION RESULTS; SEMI-AUTOMATIC ALGORITHMS;

EID: 84864591709     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6091640     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 1
    • 33846269659 scopus 로고    scopus 로고
    • Mannheim carotid intima-media thickness consensus (2004-2006). An update on behalf of the Advisory Board of the 3rd and 4th Watching the Risk Symposium, 13th and 15th European Stroke Conferences, Mannheim Germany, 2004, and Brussels, Belgum, 2006
    • P. J. Touboul, et al., "Mannheim carotid intima-media thickness consensus (2004-2006). An update on behalf of the Advisory Board of the 3rd and 4th Watching the Risk Symposium, 13th and 15th European Stroke Conferences, Mannheim Germany, 2004, and Brussels, Belgum, 2006," Cerebrovasc Dis, vol. 23, no. 1, pp. 75-80, 2007.
    • (2007) Cerebrovasc Dis , vol.23 , Issue.1 , pp. 75-80
    • Touboul, P.J.1
  • 2
    • 10844292433 scopus 로고    scopus 로고
    • Mannheim intima-media thickness consensus
    • P. J. Touboul et al., "Mannheim intima-media thickness consensus," Cerebrovasc Dis, vol. 18, no. 4, pp. 346-349, 2004.
    • (2004) Cerebrovasc Dis , vol.18 , Issue.4 , pp. 346-349
    • Touboul, P.J.1
  • 3
    • 54149096512 scopus 로고    scopus 로고
    • Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator
    • F. Faita, V. Gemignani, E. Bianchini, C. Giannarelli, L. Ghiadoni, and M. Demi, "Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator," J Ultrasound Med, vol. 27, pp. 1353-1361, 2008.
    • (2008) J Ultrasound Med , vol.27 , pp. 1353-1361
    • Faita, F.1    Gemignani, V.2    Bianchini, E.3    Giannarelli, C.4    Ghiadoni, L.5    Demi, M.6
  • 4
    • 0017905168 scopus 로고
    • Speckle in ultrasound B-mode scans
    • C. B. Burckhardt, "Speckle in ultrasound B-mode scans," IEEE Trans. Sonics Ultrason., vol. SU-25, no. 1, pp.1-6, 1978.
    • (1978) IEEE Trans. Sonics Ultrason. , vol.SU-25 , Issue.1 , pp. 1-6
    • Burckhardt, C.B.1
  • 7
    • 33745456397 scopus 로고    scopus 로고
    • Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filtering
    • C. P. Loizou, C. S. Pattichis, M. Pantziaris, T. Tyllis, and A. Nicolaides, "Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filtering," Med Biol Eng Comput, vol. 44, no. 5, pp. 414-426, 2006.
    • (2006) Med Biol Eng Comput , vol.44 , Issue.5 , pp. 414-426
    • Loizou, C.P.1    Pattichis, C.S.2    Pantziaris, M.3    Tyllis, T.4    Nicolaides, A.5
  • 9
    • 79958015020 scopus 로고    scopus 로고
    • Completely automated multi-resolution edge snapper (CAMES) - A new technique for an accurate carotid ultrasound IMT measurement and its validation on a multiinstitutional database
    • Lake Buena Vista (Orlando), FL, USA
    • F. Molinari, et al., "Completely automated multi-resolution edge snapper (CAMES) - A new technique for an accurate carotid ultrasound IMT measurement and its validation on a multiinstitutional database," in SPIE Medical Imaging Conference, Lake Buena Vista (Orlando), FL, USA, 2011.
    • (2011) SPIE Medical Imaging Conference
    • Molinari, F.1
  • 10
    • 84055215503 scopus 로고    scopus 로고
    • CARES: Completely automated robust edge snapper for carotid ultrasound IMT measurement on a multi-institutional database of 300 images
    • in press
    • F. Molinari, R. U. Acharya, G. Zeng, K.M. Meiburger and J. Suri, "CARES: Completely Automated Robust Edge Snapper for Carotid Ultrasound IMT measurement on a Multi-Institutional Database of 300 Images", Med Biol Eng Comput, (in press)
    • Med Biol Eng Comput
    • Molinari, F.1    Acharya, R.U.2    Zeng, G.3    Meiburger, K.M.4    Suri, J.5
  • 11
    • 0034421371 scopus 로고    scopus 로고
    • Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms
    • J. S. Suri, R. M. Haralick, F. H. Sheehan, "Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms," Pattern Analysis and Applications, vol. 3, no. 1, pp. 39-60, 2000.
    • (2000) Pattern Analysis and Applications , vol.3 , Issue.1 , pp. 39-60
    • Suri, J.S.1    Haralick, R.M.2    Sheehan, F.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.