Volumn 31, Issue 8, 2012, Pages 1661-1668

Ultrafast doppler imaging of blood flow dynamics in the myocardium

Author keywords

Blood flow; heart; ultrafast imaging; ultrasound

Indexed keywords

BLOOD FLOW; BLOOD FLOW DYNAMICS; CARDIAC CYCLES; CARDIO-VASCULAR DISEASE; CORONARY ARTERIES; DOPPLER; DOPPLER IMAGING; DOPPLER TECHNIQUES; FLOW DYNAMICS; FLOW WAVEFORMS; FRAME RATE; HIGH SENSITIVITY; IMAGING METHOD; IMAGING MODALITY; IN-VIVO; MYOCARDIAL BLOOD FLOW; PHASE OPPOSITION; PHYSIOLOGICAL CONDITION; PLANE WAVE; POWER DOPPLER; TEMPORAL RESOLUTION; ULTRA-FAST; ULTRAFAST IMAGING; ULTRASONIC DOPPLER; ULTRASONIC PROBE; VASCULAR FLOW;

EID: 84864581795     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2012.2203316     Document Type: Article
Times cited : (79)

References (19)
  • 2
    • 78650527024 scopus 로고    scopus 로고
    • High-resolution magnetic resonance myocardial perfusion imaging at 3.0-Tesla to detect hemodynamically significant coronary stenosis as determined by fractional flow reserve
    • T. Lockie et al., "High-resolution magnetic resonance myocardial perfusion imaging at 3.0-Tesla to detect hemodynamically significant coronary stenosis as determined by fractional flow reserve," J. Amer. Coll. Cardiol., vol. 57, no. 1, pp. 70-75, 2011.
    • (2011) J. Amer. Coll. Cardiol. , vol.57 , Issue.1 , pp. 70-75
    • Lockie, T.1
  • 3
    • 42549100507 scopus 로고    scopus 로고
    • Coronary microcirculation in the beating heart
    • F. Kajiya et al., "Coronary microcirculation in the beating heart," Med. Biol. Eng. Comput., vol. 46, pp. 411-419, 2008.
    • (2008) Med. Biol. Eng. Comput. , vol.46 , pp. 411-419
    • Kajiya, F.1
  • 4
    • 49149094134 scopus 로고    scopus 로고
    • Myocardial contrast echography: A 25-Years retrospective
    • S. Kaul, "Myocardial contrast echography: A 25-Years retrospective," Circulation, vol. 118, pp. 291-308, 2008.
    • (2008) Circulation , vol.118 , pp. 291-308
    • Kaul, S.1
  • 5
    • 24044524493 scopus 로고    scopus 로고
    • Detection of coronary stenoses at rest with myocardial contrast echocardiography
    • K.Wei,K. L. Tong, T. Belcik, P. Rafter,M. Ragosta,X.-Q. Wang, and S. Kaul, "Detection of coronary stenoses at rest with myocardial contrast echocardiography," Circulation, vol. 112, pp. 1554-1160, 2005.
    • (2005) Circulation , vol.112 , pp. 1554-1160
    • Wei, K.1    Tong, K.L.2    Belcik, T.3    Rafter, P.4    Ragosta, M.5    Wang, X.-Q.6    Kaul, S.7
  • 6
    • 0026010975 scopus 로고
    • Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation
    • S. Iliceto, V. Marangelli, C. Memmola, and P. Rizzon, "Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation," Circulation, vol. 83, pp. 61-69, 1991.
    • (1991) Circulation , vol.83 , pp. 61-69
    • Iliceto, S.1    Marangelli, V.2    Memmola, C.3    Rizzon, P.4
  • 7
    • 0032574674 scopus 로고    scopus 로고
    • Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color doppler echocardiography
    • T. Hozumi, K. Yoshida, Y. Ogata, T. Akasaka, Y. Asami, T. Takagi, and S. Morioka, "Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography," Circulation, vol. 97, pp. 1557-1562, 1998. (Pubitemid 28186183)
    • (1998) Circulation , vol.97 , Issue.16 , pp. 1557-1562
    • Hozumi, T.1    Yoshida, K.2    Ogata, Y.3    Akasaka, T.4    Asami, Y.5    Takagi, T.6    Morioka, S.7
  • 8
    • 0032962746 scopus 로고    scopus 로고
    • New noninvasive method for coronary flow reserve assessment: Contrast- enhanced transthoracic second harmonic echo Doppler
    • C. Caiati, C. Montaldo, N. Zedda, A. Bina, and S. Iliceto, "New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler," Circulation, vol. 99, pp. 771-778, 1999. (Pubitemid 29083017)
    • (1999) Circulation , vol.99 , Issue.6 , pp. 771-778
    • Caiati, C.1    Montaldo, C.2    Zedda, N.3    Bina, A.4    Iliceto, S.5
  • 9
    • 0032962746 scopus 로고    scopus 로고
    • New noninvasive method for coronary flow reserve assessment: Contrast- enhanced transthoracic second harmonic echo Doppler
    • C. Caiati, C. Montaldo, N. Zedda, A. Bina, and S. Iliceto, "New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler," Circulation, vol. 99, pp. 771-778, 1999. (Pubitemid 29083017)
    • (1999) Circulation , vol.99 , Issue.6 , pp. 771-778
    • Caiati, C.1    Montaldo, C.2    Zedda, N.3    Bina, A.4    Iliceto, S.5
  • 10
    • 0036771559 scopus 로고    scopus 로고
    • Ultrafast compound imaging for 2-D motion vector estimation: Application to transient elastography
    • DOI 10.1109/TUFFC.2002.1041078
    • M. Tanter, J. Bercoff, L. Sandrin, and M. Fink, "Ultrafast compound imaging for 2-D motion vector estimation: Application to transient elastography," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 49, no. 10, pp. 1363-1374, Oct. 2002. (Pubitemid 35250638)
    • (2002) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , vol.49 , Issue.10 , pp. 1363-1374
    • Tanter, M.1    Bercoff, J.2    Sandrin, L.3    Fink, M.4
  • 12
    • 33845602290 scopus 로고    scopus 로고
    • High frame rate imaging system for limited diffraction array beam imaging with square-wave aperture weightings
    • Oct
    • J. Lu, J. Cheng, and J.Wang, "High frame rate imaging system for limited diffraction array beam imaging with square-wave aperture weightings," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 53, no. 10, pp. 1796-1812, Oct. 2006.
    • (2006) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.53 , Issue.10 , pp. 1796-1812
    • Lu, J.1    Cheng, J.2    Wang, J.3
  • 13
    • 2442466831 scopus 로고    scopus 로고
    • Supersonic shear imaging: A new technique for soft tissue elasticity mapping
    • J. Bercoff, M. Tanter, and M. Fink, "Supersonic shear imaging: A new technique for soft tissue elasticity mapping," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 51, no. 4, pp. 396-409, 2004.
    • (2004) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.51 , Issue.4 , pp. 396-409
    • Bercoff, J.1    Tanter, M.2    Fink, M.3
  • 15
    • 49549105568 scopus 로고    scopus 로고
    • High frame-rate blood vector velocity imaging using plane waves: Simulations and preliminary experiments
    • Aug
    • J. Udesen, F. Gran, K. Lindskov Hansen, and J. A. Jensen, "High frame-rate blood vector velocity imaging using plane waves: Simulations and preliminary experiments," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 55, no. 8, pp. 1729-1743, Aug. 2008.
    • (2008) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.55 , Issue.8 , pp. 1729-1743
    • Udesen, J.1    Gran, F.2    Lindskov Hansen, K.3    Jensen, J.A.4
  • 16
    • 78751662185 scopus 로고    scopus 로고
    • Ultrafast compound Doppler imaging: Providing full blood flow characterization
    • Jan
    • J. Bercoff et al., "Ultrafast compound Doppler imaging: providing full blood flow characterization," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 58, no. 1, pp. 134-147, Jan. 2011.
    • (2011) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.58 , Issue.1 , pp. 134-147
    • Bercoff, J.1
  • 17
    • 79961008625 scopus 로고    scopus 로고
    • Functional ultrasound imaging of the brain
    • E. Mace et al., "Functional ultrasound imaging of the brain," Nature Meth., vol. 8, pp. 662-664, 2010.
    • (2010) Nature Meth. , vol.8 , pp. 662-664
    • Mace, E.1
  • 18
    • 65349145884 scopus 로고    scopus 로고
    • Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
    • Mar
    • G. Montaldo et al., "Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 56, no. 3, pp. 489-506, Mar. 2009.
    • (2009) IEEE Trans. Ultrason., Ferroelect., Freq. Contr. , vol.56 , Issue.3 , pp. 489-506
    • Montaldo, G.1
  • 19
    • 0031468921 scopus 로고    scopus 로고
    • A least-squares strain estimator for elastography
    • F. Kallel et al., "A least-squares strain estimator for elastography," Ultrason. Imag., vol. 19, pp. 195-208, 1997. (Pubitemid 28036069)
    • (1997) Ultrasonic Imaging , vol.19 , Issue.3 , pp. 195-208
    • Kallel, F.1    Ophir, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.