메뉴 건너뛰기




Volumn 8, Issue 3, 2012, Pages 545-553

Short-circuit fault protection strategy for high-power three-phase three-wire inverter

Author keywords

Fault protection; high reliability; short circuit fault; three phase three wire combined inverter

Indexed keywords

CRITICAL LOAD; CURRENT SOURCES; DESIGN CONSIDERATIONS; FAULT PROTECTION; HIGH RELIABILITY; HIGH-POWER; HYSTERESIS CURRENT CONTROL; NORMAL STATE; OPERATIONAL PRINCIPLES; OUTPUT CURRENT; OUTPUT VOLTAGES; SELECTIVE PROTECTION; SHORT-CIRCUIT FAULT; SOFTWARE CONTROLLERS; SWITCHING DEVICES; SYNCHRONOUS ROTATING FRAMES; THREE PHASE FAULTS; THREE-PHASE THREE-WIRE; VOLTAGE SOURCE;

EID: 84864566388     PISSN: 15513203     EISSN: None     Source Type: Journal    
DOI: 10.1109/TII.2012.2187913     Document Type: Article
Times cited : (71)

References (25)
  • 1
    • 42549110493 scopus 로고    scopus 로고
    • On the efficiency of voltage source and current source inverters for high-power drives
    • Apr.
    • E. P. Wiechmann, P. Aqueveque, R. Burgos, and J. Rodriguez, "On the efficiency of voltage source and current source inverters for high-power drives," IEEE Trans. Ind. Electron., vol. 55, no. 4, pp. 1771-1782, Apr. 2008.
    • (2008) IEEE Trans. Ind. Electron. , vol.55 , Issue.4 , pp. 1771-1782
    • Wiechmann, E.P.1    Aqueveque, P.2    Burgos, R.3    Rodriguez, J.4
  • 2
    • 77954591210 scopus 로고    scopus 로고
    • An effective control technique for medium-voltage high-power induction motor fed by cascaded neutral-point-clamped inverter
    • Aug.
    • B. Ge, F. Z. Peng, A. T. de Almeida, and H. Abu-Rub, "An effective control technique for medium-voltage high-power induction motor fed by cascaded neutral-point-clamped inverter," IEEE Trans. Ind. Electron., vol. 57, no. 8, pp. 2659-2668, Aug. 2010.
    • (2010) IEEE Trans. Ind. Electron. , vol.57 , Issue.8 , pp. 2659-2668
    • Ge, B.1    Peng, F.Z.2    De Almeida, A.T.3    Abu-Rub, H.4
  • 3
    • 79952721720 scopus 로고    scopus 로고
    • Filter optimization for grid interactive voltage source inverters
    • Dec.
    • P. Channegowda and V. John, "Filter optimization for grid interactive voltage source inverters," IEEE Trans. Ind. Electron., vol. 57, no. 12, pp. 4106-4114, Dec. 2010.
    • (2010) IEEE Trans. Ind. Electron. , vol.57 , Issue.12 , pp. 4106-4114
    • Channegowda, P.1    John, V.2
  • 4
    • 79959317611 scopus 로고    scopus 로고
    • Switching frequency reduction using model predictive direct current control for high-power voltage source inverters
    • Jul.
    • M. Preindl, E. Schaltz, and P. Thogersen, "Switching frequency reduction using model predictive direct current control for high-power voltage source inverters," IEEE Trans. Ind. Electron., vol. 58, no. 7, pp. 2826-2835, Jul. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.7 , pp. 2826-2835
    • Preindl, M.1    Schaltz, E.2    Thogersen, P.3
  • 5
    • 79955823424 scopus 로고    scopus 로고
    • DSP-based control of grid-connected power converters operating under grid distortions
    • May
    • M. P. Kazmierkowski, M. Jasinski, and G. Wrona, "DSP-based control of grid-connected power converters operating under grid distortions," IEEE Trans. Ind. Informat., vol. 7, no. 2, pp. 204-211, May 2011.
    • (2011) IEEE Trans. Ind. Informat. , vol.7 , Issue.2 , pp. 204-211
    • Kazmierkowski, M.P.1    Jasinski, M.2    Wrona, G.3
  • 6
    • 79952647892 scopus 로고    scopus 로고
    • Grid-filter design for a multimegawatt medium-voltage voltage-source inverter
    • Apr.
    • A. A. Rockhill, M. Liserre, R. Teodorescu, and P. Rodriguez, "Grid-filter design for a multimegawatt medium-voltage voltage-source inverter," IEEE Trans. Ind. Electron., vol. 58, no. 4, pp. 1205-1217, Apr. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.4 , pp. 1205-1217
    • Rockhill, A.A.1    Liserre, M.2    Teodorescu, R.3    Rodriguez, P.4
  • 8
    • 78650379423 scopus 로고    scopus 로고
    • Reliability and availability performances of a universal and flexible power management system
    • Jul.
    • M.C. Magro and S. Savio, "Reliability and availability performances of a universal and flexible power management system," Proc. IEEE ISIE, pp. 2461-2468, Jul. 2010.
    • (2010) Proc. IEEE ISIE , pp. 2461-2468
    • Magro, M.C.1    Savio, S.2
  • 9
    • 79959289557 scopus 로고    scopus 로고
    • Long-term reliability of railway power inverters cooled by heat-pipe-based systems
    • Jul.
    • X. Perpina, X. Jorda, M. Vellvehi, J. Rebollo, and M. Mermet-Guyennet, "Long-term reliability of railway power inverters cooled by heat-pipe-based systems," IEEE Trans. Ind. Electron., vol. 58, no. 7, pp. 2662-2672, Jul. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.7 , pp. 2662-2672
    • Perpina, X.1    Jorda, X.2    Vellvehi, M.3    Rebollo, J.4    Mermet-Guyennet, M.5
  • 10
    • 67651162406 scopus 로고    scopus 로고
    • Study on a series resistive SFCL to improve power system transient stability: Modeling, simulation, and experimental verification
    • Jul.
    • B. C. Sung, D. K. Park, J. W. Park, and T. K. Ko, "Study on a series resistive SFCL to improve power system transient stability: Modeling, simulation, and experimental verification," IEEE Trans. Ind. Electron., vol. 56, no. 7, pp. 2412-2419, Jul. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.7 , pp. 2412-2419
    • Sung, B.C.1    Park, D.K.2    Park, J.W.3    Ko, T.K.4
  • 11
    • 76649119439 scopus 로고    scopus 로고
    • Unsymmetrical short-circuit fault analysis for weakly meshed distribution systems
    • Feb.
    • J. Teng, "Unsymmetrical short-circuit fault analysis for weakly meshed distribution systems," IEEE Trans. Power Syst., vol. 25, no. 1, pp. 96-105, Feb. 2010.
    • (2010) IEEE Trans. Power Syst. , vol.25 , Issue.1 , pp. 96-105
    • Teng, J.1
  • 12
    • 84856557104 scopus 로고    scopus 로고
    • Challenges and opportunities for inverters in microgrids
    • Nov.
    • D. Cornforth, T. Moore, and S. Sayeef, "Challenges and opportunities for inverters in microgrids," Proc. IEEE IECON, pp. 3111-3116, Nov. 2011.
    • (2011) Proc. IEEE IECON , pp. 3111-3116
    • Cornforth, D.1    Moore, T.2    Sayeef, S.3
  • 13
    • 0033359314 scopus 로고    scopus 로고
    • A fault protection scheme for series active power filters
    • Sep.
    • L. A. Moran, I. Pastorini, J. Dixon, and R. Wallace, "A fault protection scheme for series active power filters," IEEE Trans. Power Electron., vol. 14, no. 5, pp. 928-938, Sep. 1999.
    • (1999) IEEE Trans. Power Electron. , vol.14 , Issue.5 , pp. 928-938
    • Moran, L.A.1    Pastorini, I.2    Dixon, J.3    Wallace, R.4
  • 14
    • 57849106372 scopus 로고    scopus 로고
    • An adaptive over-current protection scheme for MV distribution networks including DG
    • Jun.
    • S. A. M. Javadian, M. R. Haghifam, and P. Barazandeh, "An adaptive over-current protection scheme for MV distribution networks including DG," Proc. IEEE ISIE, pp. 2520-2525, Jun. 2008.
    • (2008) Proc. IEEE ISIE , pp. 2520-2525
    • Javadian, S.A.M.1    Haghifam, M.R.2    Barazandeh, P.3
  • 15
    • 0036577706 scopus 로고    scopus 로고
    • An integrated approach for the protection of series injection inverters
    • May
    • M. J. Newman and D. G. Holmes, "An integrated approach for the protection of series injection inverters," IEEE Trans. Ind. Appl., vol. 38, no. 3, pp. 679-687, May 2002.
    • (2002) IEEE Trans. Ind. Appl. , vol.38 , Issue.3 , pp. 679-687
    • Newman, M.J.1    Holmes, D.G.2
  • 16
    • 77951581087 scopus 로고    scopus 로고
    • A novel wide voltage range bi-directional series resonant converter with clamped capacitor voltage
    • Nov.
    • Y. Du, X. Bian, S. Lukic, B. S. Jacobson, and A. Q. Huang, "A novel wide voltage range bi-directional series resonant converter with clamped capacitor voltage," Proc. IEEE IECON, pp. 82-87, Nov. 2009.
    • (2009) Proc. IEEE IECON , pp. 82-87
    • Du, Y.1    Bian, X.2    Lukic, S.3    Jacobson, B.S.4    Huang, A.Q.5
  • 17
    • 78651573428 scopus 로고    scopus 로고
    • Protection of unified power quality conditioner against the load side short circuits
    • I. Axente, M. Basu, M. F. Conlon, and K. Gaughan, "Protection of unified power quality conditioner against the load side short circuits," IET Power Electron., vol. 3, no. 4, pp. 542-551, 2010.
    • (2010) IET Power Electron. , vol.3 , Issue.4 , pp. 542-551
    • Axente, I.1    Basu, M.2    Conlon, M.F.3    Gaughan, K.4
  • 18
    • 33847692686 scopus 로고    scopus 로고
    • Combined three-phase inverters with high frequency pulse DC link
    • D. L. Chen, X. Li, R. Zhang, and H. T. Zhang, "Combined three-phase inverters with high frequency pulse DC link," Proc. IEEE-PESC, pp. 835-841, 2005.
    • (2005) Proc. IEEE-PESC , pp. 835-841
    • Chen, D.L.1    Li, X.2    Zhang, R.3    Zhang, H.T.4
  • 19
    • 79954464727 scopus 로고    scopus 로고
    • On the distribution of ac and dc winding capacitances in high-frequency power transformers with rectifier loads
    • May
    • P. Ranstad and H. P. Nee, "On the distribution of ac and dc winding capacitances in high-frequency power transformers with rectifier loads," IEEE Trans. Ind. Electron., vol. 58, no. 5, pp. 1789-1798, May 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.5 , pp. 1789-1798
    • Ranstad, P.1    Nee, H.P.2
  • 20
    • 79956371622 scopus 로고    scopus 로고
    • An industry-based survey of reliability in power electronic converters
    • May
    • S. Yang, A. Bryant, P. Mawby, D. Xiang, R. Li, and P. Tavner, "An industry-based survey of reliability in power electronic converters," IEEE Trans. Ind. Appl., vol. 47, no. 3, pp. 1441-1451, May 2011.
    • (2011) IEEE Trans. Ind. Appl. , vol.47 , Issue.3 , pp. 1441-1451
    • Yang, S.1    Bryant, A.2    Mawby, P.3    Xiang, D.4    Li, R.5    Tavner, P.6
  • 21
    • 80053645925 scopus 로고    scopus 로고
    • Improvement of matrix converter drive-reliability by online fault detection and a fault-tolerant switching strategy
    • Jan.
    • K. Nguyen-Duy, T. Liu, D. Chen, and J. Y. Hung, "Improvement of matrix converter drive-reliability by online fault detection and a fault-tolerant switching strategy," IEEE Trans. Ind. Electron., vol. 59, no. 1, pp. 244-256, Jan. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.59 , Issue.1 , pp. 244-256
    • Nguyen-Duy, K.1    Liu, T.2    Chen, D.3    Hung, J.Y.4
  • 22
    • 80053182178 scopus 로고    scopus 로고
    • Modulation for three-phase transformerless Z-source inverter to reduce leakage currents in photovoltaic systems
    • Dec.
    • F. Bradaschia, M. C. Cavalcanti, P. E. P. Ferraz, F. A. S. Neves, E. C. dos Santos, and J. H. G. M. da Silva, "Modulation for three-phase transformerless Z-source inverter to reduce leakage currents in photovoltaic systems," IEEE Trans. Ind. Electron., vol. 58, no. 12, pp. 5385-5395, Dec. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.12 , pp. 5385-5395
    • Bradaschia, F.1    Cavalcanti, M.C.2    Ferraz, P.E.P.3    Neves, F.A.S.4    Dos Santos, E.C.5    Da Silva, J.H.G.M.6
  • 23
    • 60449091304 scopus 로고    scopus 로고
    • Limitations of voltage-oriented PI current control of grid-connected PWM rectifiers with LCL filters
    • Feb.
    • J. Dannehl, C. Wessels, and F. W. Fuchs, "Limitations of voltage-oriented PI current control of grid-connected PWM rectifiers with LCL filters," IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 380-388, Feb. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.2 , pp. 380-388
    • Dannehl, J.1    Wessels, C.2    Fuchs, F.W.3
  • 24
    • 79956273176 scopus 로고    scopus 로고
    • Hybrid multiconverter conditioner topology for high-power applications
    • Jun.
    • M. I. Milanes-Montero, E. Romero-Cadaval, and F. Barrero-Gonzalez, "Hybrid multiconverter conditioner topology for high-power applications," IEEE Trans. Ind. Electron., vol. 58, no. 6, pp. 2283-2292, Jun. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.6 , pp. 2283-2292
    • Milanes-Montero, M.I.1    Romero-Cadaval, E.2    Barrero-Gonzalez, F.3
  • 25
    • 78651357963 scopus 로고    scopus 로고
    • Analysis and simplification of three-dimensional space vector PWM for three-phase four-leg inverters
    • Feb.
    • X. Li, Z. Deng, Z. Chen, and Q. Fei, "Analysis and simplification of three-dimensional space vector PWM for three-phase four-leg inverters," IEEE Trans. Ind. Electron., vol. 58, no. 2, pp. 450-464, Feb. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.2 , pp. 450-464
    • Li, X.1    Deng, Z.2    Chen, Z.3    Fei, Q.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.