메뉴 건너뛰기




Volumn 12, Issue , 2012, Pages

Field comparison of OraQuick® ADVANCE Rapid HIV-1/2 antibody test and two blood-based rapid HIV antibody tests in Zambia

Author keywords

Cost; HIV; OraQuick ; Zambia

Indexed keywords

ADULT; ALGORITHM; ARTICLE; COMMUNITY; CONTROLLED STUDY; COST BENEFIT ANALYSIS; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; HIV TEST; HUMAN; HUMAN IMMUNODEFICIENCY VIRUS INFECTION; HUMAN IMMUNODEFICIENCY VIRUS PREVALENCE; IMMUNOASSAY; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; NONHUMAN; PREDICTIVE VALUE; QUESTIONNAIRE; SENSITIVITY AND SPECIFICITY; ZAMBIA;

EID: 84864535442     PISSN: None     EISSN: 14712334     Source Type: Journal    
DOI: 10.1186/1471-2334-12-183     Document Type: Article
Times cited : (49)

References (30)
  • 1
    • 80051885467 scopus 로고    scopus 로고
    • Lusaka: Government of the Republic of Zambia, Ministry of Health
    • Ministry of Health Adult and adolescent antiretroviral therapy protocols 2010, Lusaka: Government of the Republic of Zambia, Ministry of Health.
    • (2010) Adult and adolescent antiretroviral therapy protocols
  • 2
    • 0031581933 scopus 로고    scopus 로고
    • Revised recommendations for the selection and use of HIV antibody tests
    • Joint United Nations Program on HIV/AIDS (UNAIDS)- World Health Organization(WHO)
    • Joint United Nations Program on HIV/AIDS (UNAIDS)- World Health Organization(WHO) Revised recommendations for the selection and use of HIV antibody tests. Wkly Epidemiol Rec 1997, 72:81-87. Joint United Nations Program on HIV/AIDS (UNAIDS)- World Health Organization(WHO).
    • (1997) Wkly Epidemiol Rec , vol.72 , pp. 81-87
  • 10
    • 33645301347 scopus 로고    scopus 로고
    • Removing barriers to knowing HIV status. Same-day mobile HIV testing in Zimbabwe
    • 10.1097/01.qai.0000179455.01068.ab, 16394855
    • Morin SF, Khumalo-Sakutukwa G, Charlebois ED. Removing barriers to knowing HIV status. Same-day mobile HIV testing in Zimbabwe. J Acquir Immune Defic Syndr 2006, 41(2):218-224. 10.1097/01.qai.0000179455.01068.ab, 16394855.
    • (2006) J Acquir Immune Defic Syndr , vol.41 , Issue.2 , pp. 218-224
    • Morin, S.F.1    Khumalo-Sakutukwa, G.2    Charlebois, E.D.3
  • 11
    • 0034069344 scopus 로고    scopus 로고
    • HIV topic update: oro-genital transmission of HIV
    • Scully C, Porter S. HIV topic update: oro-genital transmission of HIV. Oral Dis 2000, 6(2):92-98.
    • (2000) Oral Dis , vol.6 , Issue.2 , pp. 92-98
    • Scully, C.1    Porter, S.2
  • 12
    • 33646672435 scopus 로고    scopus 로고
    • Oral transmission of HIV, reality or fiction? an update
    • 10.1111/j.1601-0825.2005.01187.x, 16700731
    • Campo J, Perea MA, del Romero J, Cano J, Hernando V, Bascones A. Oral transmission of HIV, reality or fiction? an update. Oral Dis 2006, 12(3):219-228. 10.1111/j.1601-0825.2005.01187.x, 16700731.
    • (2006) Oral Dis , vol.12 , Issue.3 , pp. 219-228
    • Campo, J.1    Perea, M.A.2    del Romero, J.3    Cano, J.4    Hernando, V.5    Bascones, A.6
  • 13
    • 80055029916 scopus 로고    scopus 로고
    • The uptake and accuracy of oral kits for HIV self-testing in high HIV prevalence setting: a cross-sectional feasibility study in Blantyre, Malawi
    • 10.1371/journal.pmed.1001102, 3186813, 21990966
    • Choko AT, Desmond N, Webb EL, Chavula K, Napierala-Mavedzenge S, Gaydos CA, Makombe SD, Chunda T, Squire SB, French N, et al. The uptake and accuracy of oral kits for HIV self-testing in high HIV prevalence setting: a cross-sectional feasibility study in Blantyre, Malawi. PLoS Med 2011, 8(10):e1001102. 10.1371/journal.pmed.1001102, 3186813, 21990966.
    • (2011) PLoS Med , vol.8 , Issue.10
    • Choko, A.T.1    Desmond, N.2    Webb, E.L.3    Chavula, K.4    Napierala-Mavedzenge, S.5    Gaydos, C.A.6    Makombe, S.D.7    Chunda, T.8    Squire, S.B.9    French, N.10
  • 15
    • 77955371722 scopus 로고    scopus 로고
    • Sensitivity of five rapid HIV tests on oral fluid or finger-stick whole blood: a real-time comparison in a healthcare setting
    • 10.1371/journal.pone.0011581, 2906506, 20657834
    • Pavie J, Rachline A, Loze B, Niedbalski L, Delaugerre C, Laforgerie E, Plantier JC, Rozenbaum W, Chevret S, Molina JM, et al. Sensitivity of five rapid HIV tests on oral fluid or finger-stick whole blood: a real-time comparison in a healthcare setting. PLoS One 2010, 5(7):e11581. 10.1371/journal.pone.0011581, 2906506, 20657834.
    • (2010) PLoS One , vol.5 , Issue.7
    • Pavie, J.1    Rachline, A.2    Loze, B.3    Niedbalski, L.4    Delaugerre, C.5    Laforgerie, E.6    Plantier, J.C.7    Rozenbaum, W.8    Chevret, S.9    Molina, J.M.10
  • 16
    • 53649104934 scopus 로고    scopus 로고
    • Comparison of two rapid human immunodeficiency virus (HIV) assays, Determine® HIV-1/2 and OraQuick® Advance Rapid HIV-1/2, for detection of recent HIV seroconversion
    • 10.1128/JCM.00665-08, 2566129, 18685013
    • Kshatriya R, Cachafeiro AA, Kerr RJ, Nelson JA, Fiscus SA. Comparison of two rapid human immunodeficiency virus (HIV) assays, Determine® HIV-1/2 and OraQuick® Advance Rapid HIV-1/2, for detection of recent HIV seroconversion. J Clin Microbiol 2008, 46(10):3482-3483. 10.1128/JCM.00665-08, 2566129, 18685013.
    • (2008) J Clin Microbiol , vol.46 , Issue.10 , pp. 3482-3483
    • Kshatriya, R.1    Cachafeiro, A.A.2    Kerr, R.J.3    Nelson, J.A.4    Fiscus, S.A.5
  • 17
    • 0142088653 scopus 로고    scopus 로고
    • Evaluation of saliva-based diagnostic test kit for routine detection of antibodies to HIV
    • Akanmu AS, Akinsete I, Adesemoye EF, Okany CC. Evaluation of saliva-based diagnostic test kit for routine detection of antibodies to HIV. Afr J Med Med Sci 2001, 30(4):305-308.
    • (2001) Afr J Med Med Sci , vol.30 , Issue.4 , pp. 305-308
    • Akanmu, A.S.1    Akinsete, I.2    Adesemoye, E.F.3    Okany, C.C.4
  • 18
    • 69249119007 scopus 로고    scopus 로고
    • Field evaluation of diagnostic accuracy of an oral fluid rapid test for HIV, tested at point-of-service sites in rural Zimbabwe
    • 10.1089/apc.2008.0225, 2856437, 19530953
    • Pascoe SJ, Langhaug LF, Mudzori J, Burke E, Hayes R, Cowan FM. Field evaluation of diagnostic accuracy of an oral fluid rapid test for HIV, tested at point-of-service sites in rural Zimbabwe. AIDS Patient Care STDS 2009, 23(7):571-576. 10.1089/apc.2008.0225, 2856437, 19530953.
    • (2009) AIDS Patient Care STDS , vol.23 , Issue.7 , pp. 571-576
    • Pascoe, S.J.1    Langhaug, L.F.2    Mudzori, J.3    Burke, E.4    Hayes, R.5    Cowan, F.M.6
  • 20
    • 35348879830 scopus 로고    scopus 로고
    • Large-scale human immunodeficiency virus rapid test evaluation in a low-prevalence ugandan blood bank population
    • 10.1128/JCM.00894-07, 2045340, 17699650
    • Eller LA, Eller MA, Ouma BJ, Kataaha P, Bagaya BS, Olemukan RL, Erima S, Kawala L, de Souza MS, Kibuuka H, et al. Large-scale human immunodeficiency virus rapid test evaluation in a low-prevalence ugandan blood bank population. J Clin Microbiol 2007, 45(10):3281-3285. 10.1128/JCM.00894-07, 2045340, 17699650.
    • (2007) J Clin Microbiol , vol.45 , Issue.10 , pp. 3281-3285
    • Eller, L.A.1    Eller, M.A.2    Ouma, B.J.3    Kataaha, P.4    Bagaya, B.S.5    Olemukan, R.L.6    Erima, S.7    Kawala, L.8    de Souza, M.S.9    Kibuuka, H.10
  • 21
    • 78649376665 scopus 로고    scopus 로고
    • Acute dengue fever causes false-positive reactivity in OraQuick® rapid HIV-1/2 antibody test
    • 10.1097/QAI.0b013e3181f5b291, 21931283
    • Mao A, Obi-Gwacham C, Hill T, Ryan C, Hendricks A, McKellar M. Acute dengue fever causes false-positive reactivity in OraQuick® rapid HIV-1/2 antibody test. J Acquir Immune Defic Syndr 2010, 55(5):641. 10.1097/QAI.0b013e3181f5b291, 21931283.
    • (2010) J Acquir Immune Defic Syndr , vol.55 , Issue.5 , pp. 641
    • Mao, A.1    Obi-Gwacham, C.2    Hill, T.3    Ryan, C.4    Hendricks, A.5    McKellar, M.6
  • 22
    • 56849084065 scopus 로고    scopus 로고
    • ZAMSTAR, the Zambia South Africa TB and HIV reduction study: design of a 2 x 2 factorial community randomized trial
    • 10.1186/1745-6215-9-63, 2585552, 18992133
    • Ayles HM, Sismanidis C, Beyers N, Hayes RJ, Godfrey-Faussett P. ZAMSTAR, the Zambia South Africa TB and HIV reduction study: design of a 2 x 2 factorial community randomized trial. Trials 2008, 9:63. 10.1186/1745-6215-9-63, 2585552, 18992133.
    • (2008) Trials , vol.9 , pp. 63
    • Ayles, H.M.1    Sismanidis, C.2    Beyers, N.3    Hayes, R.J.4    Godfrey-Faussett, P.5
  • 23
    • 84874757532 scopus 로고    scopus 로고
    • Accessed February 15, 2012
    • Determine® HIV-1/2 http://www.bp.co.th/events/pdf/Package%20Insert%20Determine®%20HIV%20eng.pdf, Accessed February 15, 2012.
    • Determine® HIV-1/2
  • 24
    • 84874756357 scopus 로고    scopus 로고
    • Accessed February 15, 2012
    • OraQuick® ADVANCE HIV-1/2 rapid antibody test http://orasure.com/docs/pdfs/products/OraQuick®_advance/OraQuick®-Advance-Package-Insert-English.pdf, Accessed February 15, 2012.
    • OraQuick® ADVANCE HIV-1/2 rapid antibody test
  • 25
    • 21544437626 scopus 로고    scopus 로고
    • Acccessed February 15, 2012
    • Uni-gold recombigen HIV http://www.fda.gov/downloads/BiologicsBloodVaccines/BloodBloodProducts/ApprovedProducts/PremarketApprovalsPMAs/ucm093428.pdf, Acccessed February 15, 2012.
    • Uni-gold recombigen HIV
  • 27
    • 84860277082 scopus 로고    scopus 로고
    • Head-to-head comparison of accuracy of a rapid point-of-care HIV test with oral versus whole-blood specimens: a systematic review and meta-analysis
    • 10.1016/S1473-3099(11)70368-1, 22277215
    • Pai NP, Balram B, Shivkumar S, Martinez-Cajas JL, Claessens C, Lambert G, Peeling RW, Joseph L. Head-to-head comparison of accuracy of a rapid point-of-care HIV test with oral versus whole-blood specimens: a systematic review and meta-analysis. Lancet Infect Dis 2012, 12(5):373-380. 10.1016/S1473-3099(11)70368-1, 22277215.
    • (2012) Lancet Infect Dis , vol.12 , Issue.5 , pp. 373-380
    • Pai, N.P.1    Balram, B.2    Shivkumar, S.3    Martinez-Cajas, J.L.4    Claessens, C.5    Lambert, G.6    Peeling, R.W.7    Joseph, L.8
  • 28
    • 27144432501 scopus 로고    scopus 로고
    • Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia
    • Tegbaru B, Messele T, Wolday D, Meles PH, Tesema D, Birhanu H, Tesfaye G, Bond KB, Martin R, Rayfield MA, et al. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia. Ethiop Med J 2004, 42(4):267-276.
    • (2004) Ethiop Med J , vol.42 , Issue.4 , pp. 267-276
    • Tegbaru, B.1    Messele, T.2    Wolday, D.3    Meles, P.H.4    Tesema, D.5    Birhanu, H.6    Tesfaye, G.7    Bond, K.B.8    Martin, R.9    Rayfield, M.A.10
  • 29
    • 62149124907 scopus 로고    scopus 로고
    • Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania
    • 10.1186/1471-2334-9-19, 2650699, 19226452
    • Lyamuya EF, Aboud S, Urassa WK, Sufi J, Mbwana J, Ndugulile F, Massambu C. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania. BMC Infect Dis 2009, 9:19. 10.1186/1471-2334-9-19, 2650699, 19226452.
    • (2009) BMC Infect Dis , vol.9 , pp. 19
    • Lyamuya, E.F.1    Aboud, S.2    Urassa, W.K.3    Sufi, J.4    Mbwana, J.5    Ndugulile, F.6    Massambu, C.7
  • 30
    • 70449627208 scopus 로고    scopus 로고
    • Cost of OraQuick® oral fluid rapid HIV testing at 35 community clinics and community-based organizations in the USA
    • 10.1080/09540120902729940, 20024775
    • Pinkerton SD, Bogart LM, Howerton D, Snyder S, Becker K, Asch SM. Cost of OraQuick® oral fluid rapid HIV testing at 35 community clinics and community-based organizations in the USA. AIDS Care 2009, 21(9):1157-1162. 10.1080/09540120902729940, 20024775.
    • (2009) AIDS Care , vol.21 , Issue.9 , pp. 1157-1162
    • Pinkerton, S.D.1    Bogart, L.M.2    Howerton, D.3    Snyder, S.4    Becker, K.5    Asch, S.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.