메뉴 건너뛰기




Volumn 39, Issue 4, 2012, Pages 309-316

Application of virtual surgical planning with computer assisted design and manufacturing technology to cranio-maxillofacial surgery

Author keywords

Computer aided design and manufacturing; Computer assisted image processing; Computer assisted surgery; Reconstructive surgical procedures; Three dimensional imaging

Indexed keywords

ALLOGRAFT; COMPUTER AIDED DESIGN; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER NETWORK; DIGITAL IMAGING; FACE ASYMMETRY; HEMIFACIAL MICROSOMIA; IMAGE ANALYSIS; IMAGE PROCESSING; MAXILLOFACIAL SURGERY; OUTCOME ASSESSMENT; PATIENT CARE PLANNING; RADIATION EXPOSURE; REVIEW; SIMULATION;

EID: 84864517714     PISSN: 22346163     EISSN: 22346171     Source Type: Journal    
DOI: 10.5999/aps.2012.39.4.309     Document Type: Review
Times cited : (111)

References (40)
  • 1
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography). 1. Description of system
    • Hounsfield GN. Computerized transverse axial scanning (tomography). 1. Description of system. Br J Radiol 1973; 46:1016-22.
    • (1973) Br J Radiol , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 2
    • 0015900847 scopus 로고
    • Computerized transverse axial scanning (tomography). 2. Clinical application
    • Ambrose J. Computerized transverse axial scanning (tomography). 2. Clinical application. Br J Radiol 1973;46:1023-47.
    • (1973) Br J Radiol , vol.46 , pp. 1023-1047
    • Ambrose, J.1
  • 3
    • 0029245366 scopus 로고
    • Prefabricated prostheses for the reconstruction of skull defects
    • Eufinger H, Wehmoller M, Harders A, et al. Prefabricated prostheses for the reconstruction of skull defects. Int J Oral Maxillofac Surg 1995;24:104-10.
    • (1995) Int J Oral Maxillofac Surg , vol.24 , pp. 104-110
    • Eufinger, H.1    Wehmoller, M.2    Harders, A.3
  • 5
    • 0021369275 scopus 로고
    • Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation
    • Vannier MW, Marsh JL, Warren JO. Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation. Radiology 1984;150:179-84.
    • (1984) Radiology , vol.150 , pp. 179-184
    • Vannier, M.W.1    Marsh, J.L.2    Warren, J.O.3
  • 6
    • 0023841215 scopus 로고
    • Computer-designed prostheses for orbitocranial reconstruction
    • Toth BA, Ellis DS, Stewart WB. Computer-designed prostheses for orbitocranial reconstruction. Plast Reconstr Surg 1988;81:315-24.
    • (1988) Plast Reconstr Surg , vol.81 , pp. 315-324
    • Toth, B.A.1    Ellis, D.S.2    Stewart, W.B.3
  • 8
    • 0022621474 scopus 로고
    • Three-dimensional imaging of bone from computerized tomography
    • Woolson ST, Dev P, Fellingham LL, et al. Three-dimensional imaging of bone from computerized tomography. Clin Orthop Relat Res 1986;(202):239-48.
    • (1986) Clin Orthop Relat Res , vol.202 , pp. 239-248
    • Woolson, S.T.1    Dev, P.2    Fellingham, L.L.3
  • 9
    • 0002224740 scopus 로고
    • Precision of three-dimensional CT-assisted model production in the maxillofacial area
    • Solar P, Ulm C, Lill W, et al. Precision of three-dimensional CT-assisted model production in the maxillofacial area. Eur Radiol 1992;2:473-7.
    • (1992) Eur Radiol , vol.2 , pp. 473-477
    • Solar, P.1    Ulm, C.2    Lill, W.3
  • 10
    • 0029053529 scopus 로고
    • Reconstruction of craniofacial bone defects with individual alloplastic implants based on CAD/CAM-manipulated CT-data
    • Eufinger H, Wehmoller M, Machtens E, et al. Reconstruction of craniofacial bone defects with individual alloplastic implants based on CAD/CAM-manipulated CT-data. J Craniomaxillofac Surg 1995;23:175-81.
    • (1995) J Craniomaxillofac Surg , vol.23 , pp. 175-181
    • Eufinger, H.1    Wehmoller, M.2    Machtens, E.3
  • 11
    • 0029247978 scopus 로고
    • CAD by processing of computed tomography data and CAM of individually designed prostheses
    • Wehmoller M, Eufinger H, Kruse D, et al. CAD by processing of computed tomography data and CAM of individually designed prostheses. Int J Oral Maxillofac Surg 1995;24:90-7.
    • (1995) Int J Oral Maxillofac Surg , vol.24 , pp. 90-97
    • Wehmoller, M.1    Eufinger, H.2    Kruse, D.3
  • 12
    • 0026707830 scopus 로고
    • Pediatric craniofacial surgery: Comparison of milling and stereolithography for 3D model manufacturing
    • Klein HM, Schneider W, Alzen G, et al. Pediatric craniofacial surgery: comparison of milling and stereolithography for 3D model manufacturing. Pediatr Radiol 1992;22:458-60.
    • (1992) Pediatr Radiol , vol.22 , pp. 458-460
    • Klein, H.M.1    Schneider, W.2    Alzen, G.3
  • 13
    • 0012071047 scopus 로고
    • US Patent 4,247,508. Filed December 3, Published January 27, 1981
    • Housholder R. Molding process. US Patent 4,247,508. Filed December 3, 1979. Published January 27, 1981.
    • (1979) Molding process
    • Housholder, R.1
  • 16
    • 0030952850 scopus 로고    scopus 로고
    • Rapid prototyping techniques for anatomical modelling in medicine
    • McGurk M, Amis AA, Potamianos P, et al. Rapid prototyping techniques for anatomical modelling in medicine. Ann R Coll Surg Engl 1997;79:169-74.
    • (1997) Ann R Coll Surg Engl , vol.79 , pp. 169-174
    • McGurk, M.1    Amis, A.A.2    Potamianos, P.3
  • 17
    • 0032185437 scopus 로고    scopus 로고
    • The value of stereolithographic models for preoperative diagnosis of craniofacial deformities and planning of surgical corrections
    • Sailer HF, Haers PE, Zollikofer CP, et al. The value of stereolithographic models for preoperative diagnosis of craniofacial deformities and planning of surgical corrections. Int J Oral Maxillofac Surg 1998;27:327-33.
    • (1998) Int J Oral Maxillofac Surg , vol.27 , pp. 327-333
    • Sailer, H.F.1    Haers, P.E.2    Zollikofer, C.P.3
  • 18
    • 0031916213 scopus 로고    scopus 로고
    • Indications and limitations of three-dimensional models in cranio-maxillofacial surgery
    • Santler G, Karcher H, Ruda C. Indications and limitations of three-dimensional models in cranio-maxillofacial surgery. J Craniomaxillofac Surg 1998;26:11-6.
    • (1998) J Craniomaxillofac Surg , vol.26 , pp. 11-16
    • Santler, G.1    Karcher, H.2    Ruda, C.3
  • 19
    • 0026733380 scopus 로고
    • Computer-generated titanium cranioplasty: Report of a new technique for repairing skull defects
    • Joffe JM, McDermott PJ, Linney AD, et al. Computer-generated titanium cranioplasty: report of a new technique for repairing skull defects. Br J Neurosurg 1992;6:343-50.
    • (1992) Br J Neurosurg , vol.6 , pp. 343-350
    • Joffe, J.M.1    McDermott, P.J.2    Linney, A.D.3
  • 20
    • 0028029893 scopus 로고
    • Reconstruction of posttraumatic and congenital facial deformities with three-dimensional computer-assisted custom-designed implants
    • Binder WJ, Kaye A. Reconstruction of posttraumatic and congenital facial deformities with three-dimensional computer-assisted custom-designed implants. Plast Reconstr Surg 1994;94:775-85.
    • (1994) Plast Reconstr Surg , vol.94 , pp. 775-785
    • Binder, W.J.1    Kaye, A.2
  • 21
    • 0030963194 scopus 로고    scopus 로고
    • Reconstruction of a cranial bone defect with hydroxyapatite and free flap transfer
    • Tanaka Y, Matsumoto K, Song S, et al. Reconstruction of a cranial bone defect with hydroxyapatite and free flap transfer. J Craniofac Surg 1997;8:141-5.
    • (1997) J Craniofac Surg , vol.8 , pp. 141-145
    • Tanaka, Y.1    Matsumoto, K.2    Song, S.3
  • 22
    • 0025148657 scopus 로고
    • Three-dimensional imaging in craniofacial surgery: A review of the role mirror image production
    • Fukuta F, Jackson IT, McEwan CM, et al. Three-dimensional imaging in craniofacial surgery: a review of the role mirror image production. Eur J Plast Surg 1990;13:209-17.
    • (1990) Eur J Plast Surg , vol.13 , pp. 209-217
    • Fukuta, F.1    Jackson, I.T.2    McEwan, C.M.3
  • 23
    • 0027282388 scopus 로고
    • Computer-assisted three-dimensional planning in craniofacial surgery
    • Altobelli DE, Kikinis R, Mulliken JB, et al. Computer-assisted three-dimensional planning in craniofacial surgery. Plast Reconstr Surg 1993;92:576-85.
    • (1993) Plast Reconstr Surg , vol.92 , pp. 576-585
    • Altobelli, D.E.1    Kikinis, R.2    Mulliken, J.B.3
  • 24
    • 0023690539 scopus 로고
    • Three-dimensional measurement accuracy of skull surface landmarks
    • Hildebolt CF, Vannier MW. Three-dimensional measurement accuracy of skull surface landmarks. Am J Phys Anthropol 1988;76:497-503.
    • (1988) Am J Phys Anthropol , vol.76 , pp. 497-503
    • Hildebolt, C.F.1    Vannier, M.W.2
  • 25
    • 0025282881 scopus 로고
    • Validation study of skull three-dimensional computerized tomography measurements
    • Hildebolt CF, Vannier MW, Knapp RH. Validation study of skull three-dimensional computerized tomography measurements. Am J Phys Anthropol 1990;82:283-94.
    • (1990) Am J Phys Anthropol , vol.82 , pp. 283-294
    • Hildebolt, C.F.1    Vannier, M.W.2    Knapp, R.H.3
  • 26
    • 0028154925 scopus 로고
    • Craniofacial computerassisted surgical planning and simulation
    • Lo LJ, Marsh JL, Vannier MW, et al. Craniofacial computerassisted surgical planning and simulation. Clin Plast Surg 1994;21:501-16.
    • (1994) Clin Plast Surg , vol.21 , pp. 501-516
    • Lo, L.J.1    Marsh, J.L.2    Vannier, M.W.3
  • 27
    • 0032195216 scopus 로고    scopus 로고
    • Quantitative analysis of spiral computed tomography for craniofacial clinical applications
    • Cavalcanti MG, Vannier MW. Quantitative analysis of spiral computed tomography for craniofacial clinical applications. Dentomaxillofac Radiol 1998;27:344-50.
    • (1998) Dentomaxillofac Radiol , vol.27 , pp. 344-350
    • Cavalcanti, M.G.1    Vannier, M.W.2
  • 28
    • 0034202529 scopus 로고    scopus 로고
    • Quantitative measurement on three-dimensional computed tomography: An experimental validation using phantom objects
    • Lo LJ, Lin WY, Wong HF, et al. Quantitative measurement on three-dimensional computed tomography: an experimental validation using phantom objects. Chang Gung Med J 2000;23:354-9.
    • (2000) Chang Gung Med J , vol.23 , pp. 354-359
    • Lo, L.J.1    Lin, W.Y.2    Wong, H.F.3
  • 29
    • 7944229474 scopus 로고    scopus 로고
    • Craniofacial measurements based on 3D-CT volume rendering: Implications for clinical applications
    • Cavalcanti MG, Rocha SS, Vannier MW. Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications. Dentomaxillofac Radiol 2004;33: 170-6.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 170-176
    • Cavalcanti, M.G.1    Rocha, S.S.2    Vannier, M.W.3
  • 31
    • 69249219015 scopus 로고    scopus 로고
    • Assessment of linear and angular measurements on three-dimensional conebeam computed tomographic images
    • Moreira CR, Sales MA, Lopes PM, et al. Assessment of linear and angular measurements on three-dimensional conebeam computed tomographic images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;108:430-6.
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.108 , pp. 430-436
    • Moreira, C.R.1    Sales, M.A.2    Lopes, P.M.3
  • 32
    • 67649408818 scopus 로고    scopus 로고
    • Accuracy and reliability of linear cephalometric measurements from conebeam computed tomography scans of a dry human skull
    • Berco M, Rigali PH Jr, Miner RM, et al. Accuracy and reliability of linear cephalometric measurements from conebeam computed tomography scans of a dry human skull. Am J Orthod Dentofacial Orthop 2009;136:17. e1-9.
    • (2009) Am J Orthod Dentofacial Orthop , vol.136
    • Berco, M.1    Rigali Jr., P.H.2    Miner, R.M.3
  • 33
    • 78650891523 scopus 로고    scopus 로고
    • Orthodontic measurements on digital study models compared with plaster models: A systematic review
    • Fleming PS, Marinho V, Johal A. Orthodontic measurements on digital study models compared with plaster models: a systematic review. Orthod Craniofac Res 2011;14:1-16.
    • (2011) Orthod Craniofac Res , vol.14 , pp. 1-16
    • Fleming, P.S.1    Marinho, V.2    Johal, A.3
  • 34
    • 0442264917 scopus 로고    scopus 로고
    • A survey of interactive mesh-cutting techniques and a new method for implementing generalized interactive mesh cutting using virtual tools
    • Cynthia DB, Steven S, Anil M, et al. A survey of interactive mesh-cutting techniques and a new method for implementing generalized interactive mesh cutting using virtual tools. J Visual Comput Animat 2002;13:21-42.
    • (2002) J Visual Comput Animat , vol.13 , pp. 21-42
    • Cynthia, D.B.1    Steven, S.2    Anil, M.3
  • 35
    • 22144477967 scopus 로고    scopus 로고
    • Draw and cut: Intuitive 3D osteotomy planning on polygonal bone models
    • Zachow S, Gladilina E, Saderb R, et al. Draw and cut: intuitive 3D osteotomy planning on polygonal bone models. Int Congr Ser 2003;1256:362-9.
    • (2003) Int Congr Ser , vol.1256 , pp. 362-369
    • Zachow, S.1    Gladilina, E.2    Saderb, R.3
  • 36
    • 14544288288 scopus 로고    scopus 로고
    • Three-dimensional osteotomy planning in maxillofacial surgery including soft tissue prediction
    • Westermark A, Zachow S, Eppley BL. Three-dimensional osteotomy planning in maxillofacial surgery including soft tissue prediction. J Craniofac Surg 2005;16:100-4.
    • (2005) J Craniofac Surg , vol.16 , pp. 100-104
    • Westermark, A.1    Zachow, S.2    Eppley, B.L.3
  • 38
    • 0031678238 scopus 로고    scopus 로고
    • An integrated experimental approach to link a laser digitiser, a CAD/CAM system and a rapid prototyping system for biomedical applications
    • Chua CK, Chou SM, Ng WS, et al. An integrated experimental approach to link a laser digitiser, a CAD/CAM system and a rapid prototyping system for biomedical applications. Int J Adv Manuf Technol 1998;14:110-5.
    • (1998) Int J Adv Manuf Technol , vol.14 , pp. 110-115
    • Chua, C.K.1    Chou, S.M.2    Ng, W.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.