-
1
-
-
23344432613
-
Thulium fiber laser lithotripsy: An in vitro analysis of stone fragmentation using a modulated 110-watt Thulium fiber laser at 1.94 μm
-
DOI 10.1002/lsm.20196
-
N. M. Fried, "Thulium fiber laser lithotripsy: an in vitro analysis of stone fragmentation using a modulated 110-W Thulium fiber laser at 1.94 ?m," Lasers Surg. Med. 37(1), 53-58 (2005 (Pubitemid 41105879)
-
(2005)
Lasers in Surgery and Medicine
, vol.37
, Issue.1
, pp. 53-58
-
-
Fried, N.M.1
-
2
-
-
64549129106
-
Thulium fiber laser ablation of urinary stones through small-core optical fibers
-
N. J. Scott, C. M. Cilip, and N. M. Fried, "Thulium fiber laser ablation of urinary stones through small-core optical fibers," IEEE J. Sel. Top. Quant. Electron. 15(2), 435-440 (2009
-
(2009)
IEEE J. Sel. Top. Quant. Electron
, vol.15
, Issue.2
, pp. 435-440
-
-
Scott, N.J.1
Cilip, C.M.2
Fried, N.M.3
-
3
-
-
75749130779
-
Thulium fiber laser lithotripsy using tapered fibers
-
R. L. Blackmon, P. B. Irby, and N. M. Fried, "Thulium fiber laser lithotripsy using tapered fibers," Lasers Surg. Med. 42(1), 45-50 (2010
-
(2010)
Lasers Surg. Med
, vol.42
, Issue.1
, pp. 45-50
-
-
Blackmon, R.L.1
Irby, P.B.2
Fried, N.M.3
-
4
-
-
77950526077
-
Holmium:YAG (? = 2120 nm) versus Thulium fiber (? = 1908 nm) laser lithotripsy
-
R. L. Blackmon, P. B. Irby, and N. M. Fried, "Holmium:YAG (? = 2120 nm) versus Thulium fiber (? = 1908 nm) laser lithotripsy," Lasers Surg. Med. 42(3), 232-236 (2010
-
(2010)
Lasers Surg. Med
, vol.42
, Issue.3
, pp. 232-236
-
-
Blackmon, R.L.1
Irby, P.B.2
Fried, N.M.3
-
5
-
-
79960153216
-
Comparison of Holmium: YAG and Thulium fiber laser lithotripsy: Ablation thresholds, ablation rates, and retropulsion effects
-
R. L. Blackmon, P. B. Irby, and N. M. Fried, "Comparison of Holmium: YAG and Thulium fiber laser lithotripsy: ablation thresholds, ablation rates, and retropulsion effects," J. Biomed. Opt. 16(7), 1-5 (2011
-
(2011)
J. Biomed. Opt
, vol.16
, Issue.7
, pp. 1-5
-
-
Blackmon, R.L.1
Irby, P.B.2
Fried, N.M.3
-
6
-
-
0028333680
-
Temperature dependence of the absorption coefficient of water for midinfrared laser radiation
-
E. D. Jansen et al., "Temperature dependence of the absorption coefficient of water for midinfrared laser radiation," Lasers Surg. Med. 14(3), 258-268 (1994 (Pubitemid 24139166)
-
(1994)
Lasers in Surgery and Medicine
, vol.14
, Issue.3
, pp. 258-268
-
-
Jansen, E.D.1
Van Leeuwen, T.G.2
Motamedi, M.3
Borst, C.4
Welch, A.J.5
-
7
-
-
79953749336
-
Holmium:YAG (? = 2120 nm) versus Thulium fiber laser (? = 1908 nm) ablation of kidney stones: Thresholds, rates, and retropulsion
-
R. L. Blackmon, P. B. Irby, and N. M. Fried, "Holmium:YAG (? = 2120 nm) versus Thulium fiber laser (? = 1908 nm) ablation of kidney stones: thresholds, rates, and retropulsion," Proc. SPIE 7883, 1-7 (2011
-
(2011)
Proc. SPIE
, vol.7883
, pp. 1-7
-
-
Blackmon, R.L.1
Irby, P.B.2
Fried, N.M.3
-
8
-
-
28044447177
-
Performance and safety of holmium: YAG laser optical fibers
-
DOI 10.1089/end.2005.19.1092
-
B. E. Knudsen et al., "Performance and safety of Holmium:YAG laser optical fibers," J. Endourol. 19(9), 1092-1097 (2005 (Pubitemid 41691723)
-
(2005)
Journal of Endourology
, vol.19
, Issue.9
, pp. 1092-1097
-
-
Knudsen, B.E.1
Glickman, R.D.2
Stallman, K.J.3
Maswadi, S.4
Chew, B.H.5
Beiko, D.T.6
Denstedt, J.D.7
Teichman, J.M.H.8
-
9
-
-
0032709385
-
Holmium:YAG lithotripsy: Optimal power settings
-
S. S. Spore et al., "Holmium:YAG lithotripsy: optimal power settings," J. Endourol. 13(8), 559-566 (1999
-
(1999)
J. Endourol
, vol.13
, Issue.8
, pp. 559-566
-
-
Spore, S.S.1
-
10
-
-
79960174315
-
Holmium:YAG lithotripsy fragmentation varies with pulse energy
-
L. Jonat, B. Chew, and J. Teichman, "Holmium:YAG lithotripsy fragmentation varies with pulse energy," J. Endourol. 24(12), 2135-2136 (2010
-
(2010)
J. Endourol
, vol.24
, Issue.12
, pp. 2135-2136
-
-
Jonat, L.1
Chew, B.2
Teichman, J.3
-
11
-
-
79957583102
-
Percussion drilling of metals using bursts of nanosecond pulses
-
S. T. Hendow et al., "Percussion drilling of metals using bursts of nanosecond pulses," Opt. Express 19(11), 10221-10231 (2011
-
(2011)
Opt. Express
, vol.19
, Issue.11
, pp. 10221-10231
-
-
Hendow, S.T.1
-
12
-
-
0036232480
-
Minimization of thermomechanical side effects in IR ablation by use of multiply Q-switched laser pulses
-
A. Vogel, P. Schmidt, and B. Flucke, "Minimization of thermomechanical side effects in IR ablation by use of multiply q-switched laser pulses," Med. Laser Appl. 17(1), 15-20 (2002 (Pubitemid 34456137)
-
(2002)
Medical Laser Application
, vol.17
, Issue.1
, pp. 15-20
-
-
Vogel, A.1
Schmidt, P.2
Flucke, B.3
-
13
-
-
84894273120
-
Influence of Ho:YAG pulse modification on in vitro stone disintegration
-
F. Pohl et al., "Influence of Ho:YAG pulse modification on in vitro stone disintegration," J. Endourol. 25(9), A-42 (2011)
-
(2011)
J. Endourol
, vol.25
, Issue.9
-
-
Pohl, F.1
-
14
-
-
0345035300
-
Holmium:YAG laser lithotripsy: A dominant photothermal ablative mechanism with chemical decomposition of urinary calculi
-
DOI 10.1002/(SICI)1096-9101 (1999) 25:1<22::AID-LSM4>3.0.CO;2-6
-
K. F. Chan et al., "Holmium:YAG laser lithotripsy: a dominant photothermal ablative mechanism with chemical decomposition of urinary calculi," Lasers Surg. Med. 25(1), 22-37 (1999 (Pubitemid 29379088)
-
(1999)
Lasers in Surgery and Medicine
, vol.25
, Issue.1
, pp. 22-37
-
-
Chan, K.F.1
Vassar, G.J.2
Pfefer, T.J.3
Teichman, J.M.H.4
Glickman, R.D.5
Weintraub, S.T.6
Welch, A.J.7
-
15
-
-
0000386466
-
Starting mechanisms and dynamics of bubble formation induced by a Ho:Yttrium aluminum garnet laser in water
-
M. Frenz et al., "Starting mechanisms and dynamics of bubble formation induced by a Ho:Yttrium aluminum garnet laser in water," J. Appl. Phys. 84(11), 5905-5912 (1998 (Pubitemid 128598407)
-
(1998)
Journal of Applied Physics
, vol.84
, Issue.11
, pp. 5905-5912
-
-
Frenz, M.1
Konz, F.2
Pratisto, H.3
Weber, H.P.4
Silenok, A.S.5
Konov, V.I.6
-
16
-
-
70349196215
-
Quantification of holmium:yttrium aluminum garnet optical tip degradation
-
A. C. Mues, J. M. H. Teichman, and B. E. Knudsen, "Quantification of holmium:yttrium aluminum garnet optical tip degradation," J. Endourol. 23(9), 1425-1428 (2009
-
(2009)
J. Endourol
, vol.23
, Issue.9
, pp. 1425-1428
-
-
Mues, A.C.1
Teichman, J.M.H.2
Knudsen, B.E.3
-
17
-
-
0031801561
-
Evaluation of retropulsion caused by holmium:YAG laser with various power settings and fibers
-
M. D. White et al., "Evaluation of retropulsion caused by Holmium: YAG laser with various power settings and fibers," J. Endourol. 12(2), 183-186 (1998 (Pubitemid 28233884)
-
(1998)
Journal of Endourology
, vol.12
, Issue.2
, pp. 183-186
-
-
White, M.D.1
Moran, M.E.2
Calvano, C.J.3
Borhan-Manesh, A.4
Mehlhaff, B.A.5
-
18
-
-
0037364267
-
Stone retropulsion during holmium:YAG lithotripsy
-
DOI 10.1097/01.ju.0000046367.49923.c6
-
H. Lee et al., "Stone retropulsion during Holmium:YAG Lithotripsy," J. Urol. 169(3), 881-885 (2003 (Pubitemid 36188113)
-
(2003)
Journal of Urology
, vol.169
, Issue.3
, pp. 881-885
-
-
Lee, H.1
Ryan, R.T.2
Teichman, J.M.H.3
Kim, J.4
Choi, B.5
Arakeri, N.V.6
Welch, A.J.7
-
19
-
-
27744584800
-
Effect of holmium:YAG laser pulse width on lithotripsy retropulsion in vitro
-
DOI 10.1089/end.2005.19.1041
-
D. S. Finley et al., "Effect of Holmium:YAG laser pulse width on lithotripsy retropulsion in vitro," J. Endourol. 19(8), 1041-1044 (2005 (Pubitemid 41619174)
-
(2005)
Journal of Endourology
, vol.19
, Issue.8
, pp. 1041-1044
-
-
Finley, D.S.1
Petersen, J.2
Abdelshehid, C.3
Ahlering, M.4
Chou, D.5
Borin, J.6
Eichel, L.7
McDougall, E.8
Clayman, R.V.9
-
20
-
-
17144386264
-
In vitro comparison of stone retropulsion and fragmentation of the frequency doubled, double pulse Nd:YAG laser and the holmium:YAG laser
-
DOI 10.1097/01.ju.0000154341.08206.69
-
C. G. Marguet et al., "In vitro comparison of stone retropulsion and fragmentation of the frequency doubled, double pulse Nd:YAG laser and the Holmium:YAG laser," J. Urol. 173(5), 1797-1800 (2005 (Pubitemid 40524835)
-
(2005)
Journal of Urology
, vol.173
, Issue.5
, pp. 1797-1800
-
-
Marguet, C.G.1
Sung, J.C.2
Springhart, W.P.3
L'Esperance, J.O.4
Zhou, S.5
Zhong, P.6
Albala, D.M.7
Preminger, G.M.8
-
21
-
-
33749490314
-
Dependence of calculus retropulsion on pulse duration during Ho:YAG laser lithotripsy
-
J. W. Kang et al., "Dependence of calculus retropulsion on pulse duration during Ho:YAG laser lithotripsy," Lasers Surg. Med. 38(8), 762-772 (2006
-
(2006)
Lasers Surg. Med
, vol.38
, Issue.8
, pp. 762-772
-
-
Kang, J.W.1
-
22
-
-
33947364410
-
Effect of pulse width on object movement in vitro using holmium: YAG laser
-
DOI 10.1089/end.2005.1130
-
P. Kalra, N. B. Le, and D. Bagley, "Effect of pulse width on object movement in vitro using Ho:YAG laser," J. Endourol. 21(2), 228-231 (2007 (Pubitemid 46446941)
-
(2007)
Journal of Endourology
, vol.21
, Issue.2
, pp. 228-231
-
-
Kalra, P.1
Le, N.-B.2
Bagley, D.3
|