-
1
-
-
42149175697
-
Immediate/early loading of dental implants: clinical documentation and presentation of a treatment concept
-
Östman PO. Immediate/early loading of dental implants: clinical documentation and presentation of a treatment concept. Periodontol 2000 2008; 47:90-112.
-
(2008)
Periodontol 2000
, vol.47
, pp. 90-112
-
-
Östman, P.O.1
-
3
-
-
42149147336
-
Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications
-
Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008; 47:51-66.
-
(2008)
Periodontol 2000
, vol.47
, pp. 51-66
-
-
Sennerby, L.1
Meredith, N.2
-
4
-
-
0033176199
-
A comparison between placement torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
-
Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between placement torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999; 28:297-303.
-
(1999)
Int J Oral Maxillofac Surg
, vol.28
, pp. 297-303
-
-
Friberg, B.1
Sennerby, L.2
Meredith, N.3
Lekholm, U.4
-
5
-
-
33747877743
-
A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants
-
Turkyilmaz I. A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants. J Oral Rehabil 2006; 33:754-759.
-
(2006)
J Oral Rehabil
, vol.33
, pp. 754-759
-
-
Turkyilmaz, I.1
-
6
-
-
33751351701
-
Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement
-
Turkyilmaz I, Tözüm TF, Tumer C, Ozbek EN. Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil 2006; 33:881-888.
-
(2006)
J Oral Rehabil
, vol.33
, pp. 881-888
-
-
Turkyilmaz, I.1
Tözüm, T.F.2
Tumer, C.3
Ozbek, E.N.4
-
8
-
-
0002172340
-
Patient selection and preparation
-
Brånemark P-I, Zarb GA, Albrektsson T, eds. Chicago, IL: Quintessence
-
Lekholm U, Zarb GA. Patient selection and preparation. In: Brånemark P-I, Zarb GA, Albrektsson T, eds. Tissue-integrated prostheses: osseointegration in clinical dentistry. Chicago, IL: Quintessence, 1985:199-209.
-
(1985)
Tissue-integrated prostheses: osseointegration in clinical dentistry
, pp. 199-209
-
-
Lekholm, U.1
Zarb, G.A.2
-
9
-
-
34547174147
-
Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants
-
Turkyilmaz I, Tumer C, Ozbek EN, Tözüm TF. Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants. J Clin Periodontol 2007; 34:716-722.
-
(2007)
J Clin Periodontol
, vol.34
, pp. 716-722
-
-
Turkyilmaz, I.1
Tumer, C.2
Ozbek, E.N.3
Tözüm, T.F.4
-
10
-
-
34548094603
-
Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites
-
Degidi M, Daprile G, Piattelli A, Carinci F. Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites. Clin Impl Dent Relat Res 2007; 9:144-149.
-
(2007)
Clin Impl Dent Relat Res
, vol.9
, pp. 144-149
-
-
Degidi, M.1
Daprile, G.2
Piattelli, A.3
Carinci, F.4
-
11
-
-
7744240100
-
Cutting torque measurements in conjuction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density: a possible method for identifying early implant failure?
-
Johansson B, Back T, Hirsch JM. Cutting torque measurements in conjuction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density: a possible method for identifying early implant failure? Clin Implant Dent Relat Res 2004; 6:9-14.
-
(2004)
Clin Implant Dent Relat Res
, vol.6
, pp. 9-14
-
-
Johansson, B.1
Back, T.2
Hirsch, J.M.3
-
12
-
-
7944232457
-
Implant stability measurement of delayed and immediate loaded implants during healing
-
Bischof M, Nedir R, Szmukler-Moncler D, Bernard JP, Samson J. Implant stability measurement of delayed and immediate loaded implants during healing. Clin Oral Impl Res 2004; 15:529-539.
-
(2004)
Clin Oral Impl Res
, vol.15
, pp. 529-539
-
-
Bischof, M.1
Nedir, R.2
Szmukler-Moncler, D.3
Bernard, J.P.4
Samson, J.5
-
13
-
-
60049095643
-
Influence of defect depth on resonance frequency analysis and insertion torque values for implants placet in fresh extraction sockets: ahuman cadaver study
-
Turkyilmaz I, Sennerby L, Yilmaz B, Bilecenoglu B, Ozbek EN. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placet in fresh extraction sockets: ahuman cadaver study. Clin Impl Dent Relat Res 2009; 11:52-58.
-
(2009)
Clin Impl Dent Relat Res
, vol.11
, pp. 52-58
-
-
Turkyilmaz, I.1
Sennerby, L.2
Yilmaz, B.3
Bilecenoglu, B.4
Ozbek, E.N.5
|