Primary Stability Determination by Means of Insertion Torque and RFA in a Sample of 4,135 Implants

Author keywords

Dental implants; Insertion torque; Postextractive implants; Primary stability; Resonance frequency analysis

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BONE DENSITY; DENTAL SURGERY; FEMALE; HUMAN; MALE; MANDIBLE; MAXILLA; MECHANICS; MIDDLE AGED; PHYSIOLOGY; STATISTICS; SURFACE PROPERTY; TOOTH IMPLANT; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TOOTH SOCKET; TORQUE; VERY ELDERLY; VIBRATION; WOUND HEALING; YOUNG ADULT;

EID: 84864497003     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2010.00302.x     Document Type: Article
Times cited : (81)

References (13)
  • 1
    • 42149175697 scopus 로고    scopus 로고
    • Immediate/early loading of dental implants: clinical documentation and presentation of a treatment concept
    • Östman PO. Immediate/early loading of dental implants: clinical documentation and presentation of a treatment concept. Periodontol 2000 2008; 47:90-112.
    • (2008) Periodontol 2000 , vol.47 , pp. 90-112
    • Östman, P.O.1
  • 3
    • 42149147336 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications
    • Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008; 47:51-66.
    • (2008) Periodontol 2000 , vol.47 , pp. 51-66
    • Sennerby, L.1    Meredith, N.2
  • 4
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between placement torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between placement torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999; 28:297-303.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 5
    • 33747877743 scopus 로고    scopus 로고
    • A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants
    • Turkyilmaz I. A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants. J Oral Rehabil 2006; 33:754-759.
    • (2006) J Oral Rehabil , vol.33 , pp. 754-759
    • Turkyilmaz, I.1
  • 6
    • 33751351701 scopus 로고    scopus 로고
    • Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement
    • Turkyilmaz I, Tözüm TF, Tumer C, Ozbek EN. Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil 2006; 33:881-888.
    • (2006) J Oral Rehabil , vol.33 , pp. 881-888
    • Turkyilmaz, I.1    Tözüm, T.F.2    Tumer, C.3    Ozbek, E.N.4
  • 7
    • 32644446492 scopus 로고    scopus 로고
    • Resonace frequency analysis measurements of implants at placement surgery
    • Östman PO, Hellman M, Wendelhag I, Sennerby L. Resonace frequency analysis measurements of implants at placement surgery. Int J Prosthodont 2006; 19:77-83.
    • (2006) Int J Prosthodont , vol.19 , pp. 77-83
    • Östman, P.O.1    Hellman, M.2    Wendelhag, I.3    Sennerby, L.4
  • 9
    • 34547174147 scopus 로고    scopus 로고
    • Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants
    • Turkyilmaz I, Tumer C, Ozbek EN, Tözüm TF. Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants. J Clin Periodontol 2007; 34:716-722.
    • (2007) J Clin Periodontol , vol.34 , pp. 716-722
    • Turkyilmaz, I.1    Tumer, C.2    Ozbek, E.N.3    Tözüm, T.F.4
  • 10
    • 34548094603 scopus 로고    scopus 로고
    • Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites
    • Degidi M, Daprile G, Piattelli A, Carinci F. Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites. Clin Impl Dent Relat Res 2007; 9:144-149.
    • (2007) Clin Impl Dent Relat Res , vol.9 , pp. 144-149
    • Degidi, M.1    Daprile, G.2    Piattelli, A.3    Carinci, F.4
  • 11
    • 7744240100 scopus 로고    scopus 로고
    • Cutting torque measurements in conjuction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density: a possible method for identifying early implant failure?
    • Johansson B, Back T, Hirsch JM. Cutting torque measurements in conjuction with implant placement in grafted and nongrafted maxillas as an objective evaluation of bone density: a possible method for identifying early implant failure? Clin Implant Dent Relat Res 2004; 6:9-14.
    • (2004) Clin Implant Dent Relat Res , vol.6 , pp. 9-14
    • Johansson, B.1    Back, T.2    Hirsch, J.M.3
  • 13
    • 60049095643 scopus 로고    scopus 로고
    • Influence of defect depth on resonance frequency analysis and insertion torque values for implants placet in fresh extraction sockets: ahuman cadaver study
    • Turkyilmaz I, Sennerby L, Yilmaz B, Bilecenoglu B, Ozbek EN. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placet in fresh extraction sockets: ahuman cadaver study. Clin Impl Dent Relat Res 2009; 11:52-58.
    • (2009) Clin Impl Dent Relat Res , vol.11 , pp. 52-58
    • Turkyilmaz, I.1    Sennerby, L.2    Yilmaz, B.3    Bilecenoglu, B.4    Ozbek, E.N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.