메뉴 건너뛰기




Volumn 35, Issue 6, 2012, Pages 1604-1616

Performance enhancement of CO 2 air conditioner with a controllable ejector

Author keywords

Carbon dioxide; Compressor; Controllable ejector; Cycle; Enhancement; Performance; Two phase flow; Variable speed

Indexed keywords

AIR CONDITIONERS; AIRCONDITIONING SYSTEMS; CYCLE; EJECTOR GEOMETRY; EXPANSION DEVICES; EXPANSION VALVES; MIXING SECTION; MOTIVE NOZZLE; OPERATING CONDITION; OUTDOOR-AIR TEMPERATURE; PERFORMANCE; PERFORMANCE ENHANCEMENTS; TRANSCRITICAL CO; VARIABLE OPERATING CONDITION; VARIABLE SPEED;

EID: 84864441025     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2012.05.005     Document Type: Conference Paper
Times cited : (108)

References (19)
  • 1
    • 0142126314 scopus 로고    scopus 로고
    • An evaluation of R22 substitutes performances regulating continuously the compressor refrigeration capacity
    • C. Aprea, R. Mastrullo, C. Renno, and G.P. Vanoli An evaluation of R22 substitutes performances regulating continuously the compressor refrigeration capacity Appl. Therm. Eng. 24 2004 127 139
    • (2004) Appl. Therm. Eng. , vol.24 , pp. 127-139
    • Aprea, C.1    Mastrullo, R.2    Renno, C.3    Vanoli, G.P.4
  • 2
    • 34247562854 scopus 로고    scopus 로고
    • Effect of throat diameters of the ejector on the performance of the refrigeration cycle using a two-phase ejector as an expansion device
    • P. Chaiwongsa, and S. Wongwises Effect of throat diameters of the ejector on the performance of the refrigeration cycle using a two-phase ejector as an expansion device Int. J. Refrigeration 30 2007 601 608
    • (2007) Int. J. Refrigeration , vol.30 , pp. 601-608
    • Chaiwongsa, P.1    Wongwises, S.2
  • 3
    • 34247478082 scopus 로고    scopus 로고
    • 2 cycle with an electric expansion valve and internal heat exchanger
    • 2 cycle with an electric expansion valve and internal heat exchanger Int. J. Refrigeration 30 2007 664 671
    • (2007) Int. J. Refrigeration , vol.30 , pp. 664-671
    • Cho, H.1    Ryu, C.2    Kim, Y.3
  • 5
    • 84864449799 scopus 로고    scopus 로고
    • Domanski, P.A.; 1995, Minimizing throttling losses in the refrigeration cycle. In: Proceedings of 19th International Congress of Refrigeration 1Vb, pp. 766-773
    • Domanski, P.A.; 1995, Minimizing throttling losses in the refrigeration cycle. In: Proceedings of 19th International Congress of Refrigeration 1Vb, pp. 766-773.
  • 6
    • 40049112066 scopus 로고    scopus 로고
    • Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation
    • S. Elbel, and P. Hrnjak Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation Int. J. Refrigeration 31 2008 411 422
    • (2008) Int. J. Refrigeration , vol.31 , pp. 411-422
    • Elbel, S.1    Hrnjak, P.2
  • 7
    • 84864443240 scopus 로고    scopus 로고
    • Jeong, J.; Saito, K.; Kawai, S.; Yoshikawa, C.; Hattori, K.; 2004. Efficiency enhancement of vapor compression refrigerator using natural working fluids with two-phase flow ejector. In: Proceedings 6th IIR-Gustav Lorentzen Conference on Natural Working Fluids at Glasgow, Glasgow, UK
    • Jeong, J.; Saito, K.; Kawai, S.; Yoshikawa, C.; Hattori, K.; 2004. Efficiency enhancement of vapor compression refrigerator using natural working fluids with two-phase flow ejector. In: Proceedings 6th IIR-Gustav Lorentzen Conference on Natural Working Fluids at Glasgow, Glasgow, UK.
  • 8
    • 85137259689 scopus 로고
    • An investigation of ejector design by analysis and experiment
    • H. Keenan, E.P. Neumann, and F. Lustwerk An investigation of ejector design by analysis and experiment J. Appl. Mech. ASME 72 1950 299 309
    • (1950) J. Appl. Mech. ASME , vol.72 , pp. 299-309
    • Keenan, H.1    Neumann, E.P.2    Lustwerk, F.3
  • 10
    • 84864443241 scopus 로고    scopus 로고
    • 2 as refrigerant. Ph.D. thesis, Ecole de Mines, Paris, France
    • 2 as refrigerant. Ph.D. thesis, Ecole de Mines, Paris, France
  • 11
    • 84864448634 scopus 로고    scopus 로고
    • 2 refrigeration cycle using an ejector: 1D analysis. In: Proceeding of International Refrigeration and Air Conditioning Conference at Purdue, Purdue University, USA, Paper No. R058
    • 2 refrigeration cycle using an ejector: 1D analysis. In: Proceeding of International Refrigeration and Air Conditioning Conference at Purdue, Purdue University, USA, Paper No. R058.
  • 12
    • 80052692168 scopus 로고    scopus 로고
    • 2 air conditioning system performance using an ejector
    • 2 air conditioning system performance using an ejector Int. J. Refrigeration 34 2011 1614 1625
    • (2011) Int. J. Refrigeration , vol.34 , pp. 1614-1625
    • Lee, J.S.1    Kim, M.S.2    Kim, M.S.3
  • 13
    • 84864449801 scopus 로고    scopus 로고
    • Li, D.; Groll, E.A.; 2004. Theoretical performance evaluation of a carbon dioxide based environmental control unit (ECU) with microchannel heat exchangers. In: Proceeding of the 6th IIR - Gustav Lorentzen Conference on Natural Working Fluids, Glasgow, Scotland
    • Li, D.; Groll, E.A.; 2004. Theoretical performance evaluation of a carbon dioxide based environmental control unit (ECU) with microchannel heat exchangers. In: Proceeding of the 6th IIR - Gustav Lorentzen Conference on Natural Working Fluids, Glasgow, Scotland.
  • 14
    • 20144376617 scopus 로고    scopus 로고
    • 2 refrigeration cycle with ejector-expansion device
    • 2 refrigeration cycle with ejector-expansion device Int. J. Refrigeration 28 2005 766 773
    • (2005) Int. J. Refrigeration , vol.28 , pp. 766-773
    • Li, D.1    Groll, A.E.2
  • 15
    • 84864447956 scopus 로고    scopus 로고
    • 2 cycle. In: Proceedings of Int. Refrigeration and Air Conditioning Conference at Purdue, West Lafayette, IN, USA, 2131
    • 2 cycle. In: Proceedings of Int. Refrigeration and Air Conditioning Conference at Purdue, West Lafayette, IN, USA, 2131.
  • 18
    • 0343337227 scopus 로고    scopus 로고
    • Performance analysis on a multi-type inverter air conditioner
    • Y.C. Park, Y.C. Kim, and M.K. Min Performance analysis on a multi-type inverter air conditioner Energy Convers. Manage. 42 2001 1607 1621
    • (2001) Energy Convers. Manage. , vol.42 , pp. 1607-1621
    • Park, Y.C.1    Kim, Y.C.2    Min, M.K.3
  • 19
    • 24344472962 scopus 로고    scopus 로고
    • CFD analysis of ejector in a combined ejector cooling system
    • E. Rusly, L. Aye, W.W.S. Charters, and A. Ooi CFD analysis of ejector in a combined ejector cooling system Int. J. Refrigeration 28 2005 1092 1101
    • (2005) Int. J. Refrigeration , vol.28 , pp. 1092-1101
    • Rusly, E.1    Aye, L.2    Charters, W.W.S.3    Ooi, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.