Volumn 35, Issue 6, 2012, Pages 1668-1677

Study of refrigeration system with HFO-1234yf as a working fluid Etude sur un système frigorifique utilisant le HFO-1234yf comme fluide actif

Author keywords

Boiling; Carnot; Compressor; Drop in; Evaporator; Heat transfer

Indexed keywords

CARNOT; COMPRESSOR EFFICIENCY; CONDENSATION TEMPERATURE; COOLING EFFECTS; CYCLE DATA; DROP-IN; EVAPORATION TEMPERATURE; OUTPUT POWER; PLATE HEAT EXCHANGERS; REFRIGERATION SYSTEM; ROTARY COMPRESSORS; WORKING FLUID;

EID: 84864419996     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2012.03.007     Document Type: Conference Paper
Times cited : (76)

References (12)
  • 1
    • 0021603411 scopus 로고
    • Saturation nucleate pool boiling - A simple correlation
    • M.G. Cooper Saturation nucleate pool boiling - a simple correlation IChemE Symp. Ser. 86 1984 786 793
    • (1984) IChemE Symp. Ser. , vol.86 , pp. 786-793
    • Cooper, M.G.1
  • 5
    • 85072364316 scopus 로고    scopus 로고
    • Experimental Investigation of AC system performance with HFO-1234yf as the working fluid
    • Gursaran D. Mathur, 2010. Experimental Investigation of AC system performance with HFO-1234yf as the working fluid. SAE Int. 2010-01-1207.
    • (2010) SAE Int , pp. 2010-011207
    • Mathur, G.D.1
  • 7
    • 34249982276 scopus 로고    scopus 로고
    • Refrigerant R134a vaporization heat transfer and pressure drop inside a small brazed plate heat exchanger
    • G.A. Longo, and A. Gasparella Refrigerant R134a vaporization heat transfer and pressure drop inside a small brazed plate heat exchanger Int. J. Refrigeration 30 2007 821 830
    • (2007) Int. J. Refrigeration , vol.30 , pp. 821-830
    • Longo, G.A.1    Gasparella, A.2
  • 8
    • 75349084096 scopus 로고    scopus 로고
    • HFO-1234yf low GWP refrigerant: A global sustainable solution for mobile air conditioning
    • Scottsdale, AZ, 10-12 June 2008
    • Mark Spatz, Barbara Minor, 2008. HFO-1234yf low GWP refrigerant: a global sustainable solution for mobile air conditioning. In: SAE 2008 Alternate Refrigerant Systems Symposium, Scottsdale, AZ, 10-12 June 2008.
    • (2008) SAE 2008 Alternate Refrigerant Systems Symposium
    • Spatz, M.1    Minor, B.2
  • 10
    • 84864455619 scopus 로고    scopus 로고
    • National Institute of Standards and Technology (NIST)
    • National Institute of Standards and Technology (NIST) REFPROP 7, including HFO-1234yf data 2010.
    • (2010) REFPROP 7, Including HFO-1234yf Data
  • 11
    • 44649165194 scopus 로고    scopus 로고
    • Hydrocarbons as refrigerants in small heat pump and refrigeration systems
    • B. Palm Hydrocarbons as refrigerants in small heat pump and refrigeration systems Int. J. Refrigeration 31 2008 552 563
    • (2008) Int. J. Refrigeration , vol.31 , pp. 552-563
    • Palm, B.1
  • 12
    • 84864460586 scopus 로고    scopus 로고
    • SANDEN Technical Centre (Europe), 20.08 GmbH Am.Taubenbaum, 35-37 Germany
    • SANDEN Technical Centre (Europe), 20.08. GAR Test R1234yf vs. R134a on PQ35 AC loop. GmbH Am.Taubenbaum, 35-37 Germany 2008.
    • (2008) GAR Test R1234yf Vs. R134a on PQ35 AC Loop


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.