Volumn 36, Issue 3, 2012, Pages 631-634

Utilization of a lower extremity ambulatory feedback system to reduce gait asymmetry in transtibial amputation gait

Author keywords

Amputee gait; Feedback; Gait asymmetry; Insole sensors; Wireless

Indexed keywords

ADULT; AGED; ARTICLE; FEEDBACK SYSTEM; FEMALE; GAIT; HUMAN; LEG AMPUTATION; LOWER EXTREMITY AMBULATORY FEEDBACK SYSTEM; MALE; PHYSIOTHERAPIST; PRIORITY JOURNAL; TRUNK;

EID: 84864354043     PISSN: 09666362     EISSN: 18792219     Source Type: Journal    
DOI: 10.1016/j.gaitpost.2012.04.004     Document Type: Article
Times cited : (59)

References (15)
  • 1
    • 0034282046 scopus 로고    scopus 로고
    • Symmetry and limb dominance in able-bodied gait: a review
    • Sadeghi H., Allard P., Prince F., Labelle H. Symmetry and limb dominance in able-bodied gait: a review. Gait and Posture 2000, 12:34-45.
    • (2000) Gait and Posture , vol.12 , pp. 34-45
    • Sadeghi, H.1    Allard, P.2    Prince, F.3    Labelle, H.4
  • 2
    • 33745175180 scopus 로고    scopus 로고
    • Metabolic cost of overground gait in younger stroke patients and healthy controls
    • Platts M.M., Rafferty D., Paul L. Metabolic cost of overground gait in younger stroke patients and healthy controls. Medicine and Science in Sports and Exercise 2006, 38:1041-1046.
    • (2006) Medicine and Science in Sports and Exercise , vol.38 , pp. 1041-1046
    • Platts, M.M.1    Rafferty, D.2    Paul, L.3
  • 3
    • 0347297175 scopus 로고    scopus 로고
    • Adjustments in gait symmetry with walking speed in transfemoral and trans-tibial amputees
    • Nolan L., Wit A., Dudzinski K., Lees A., Lake M., Wychowanski M. Adjustments in gait symmetry with walking speed in transfemoral and trans-tibial amputees. Gait and Posture 2003, 17:142-151.
    • (2003) Gait and Posture , vol.17 , pp. 142-151
    • Nolan, L.1    Wit, A.2    Dudzinski, K.3    Lees, A.4    Lake, M.5    Wychowanski, M.6
  • 6
    • 84873090147 scopus 로고    scopus 로고
    • National Limb Loss Information Center. Diabetes and lower extremity amputations. ACA fact sheet [accessed 16.08.08].
    • National Limb Loss Information Center. Diabetes and lower extremity amputations. ACA fact sheet 2008. [accessed 16.08.08]. http://www.amputee-coalition.org/fact_sheets/diabetes_leamp.pdf.
    • (2008)
  • 9
    • 0029837390 scopus 로고    scopus 로고
    • Use of an instrumented treadmill for real-time gait symmetry evaluation and feedback in normal and trans-tibial amputee subjects
    • Dingwell J.B., Davis B.L., Frazier D.M. Use of an instrumented treadmill for real-time gait symmetry evaluation and feedback in normal and trans-tibial amputee subjects. Prosthetics and Orthotics International 1996, 20:101-110.
    • (1996) Prosthetics and Orthotics International , vol.20 , pp. 101-110
    • Dingwell, J.B.1    Davis, B.L.2    Frazier, D.M.3
  • 10
    • 0034173921 scopus 로고    scopus 로고
    • A treadmill-based system for measuring symmetry of gait
    • Draper E.R. A treadmill-based system for measuring symmetry of gait. Medical Engineering and Physics 2000, 22:215-222.
    • (2000) Medical Engineering and Physics , vol.22 , pp. 215-222
    • Draper, E.R.1
  • 11
    • 36749043210 scopus 로고    scopus 로고
    • Balance control enhancement using sub-sensory stimulation and visual-auditory biofeedback strategies for amputee subjects
    • Lee M.Y., Lin C.F., Soon K.S. Balance control enhancement using sub-sensory stimulation and visual-auditory biofeedback strategies for amputee subjects. Prosthetics and Orthotics International 2007, 31(4):342-352.
    • (2007) Prosthetics and Orthotics International , vol.31 , Issue.4 , pp. 342-352
    • Lee, M.Y.1    Lin, C.F.2    Soon, K.S.3
  • 13
    • 75149165606 scopus 로고    scopus 로고
    • The lower extremity ambulation feedback system (LEAFS) for analysis of gait asymmetries: preliminary design and validation results
    • Bamberg S.J.M., Carson R.J., Stoddard G., Dyer P.S., Webster J.B. The lower extremity ambulation feedback system (LEAFS) for analysis of gait asymmetries: preliminary design and validation results. Journal of Prosthetics and Orthotics 2010, 22(1):31-36.
    • (2010) Journal of Prosthetics and Orthotics , vol.22 , Issue.1 , pp. 31-36
    • Bamberg, S.J.M.1    Carson, R.J.2    Stoddard, G.3    Dyer, P.S.4    Webster, J.B.5
  • 15
    • 84860666032 scopus 로고    scopus 로고
    • A wireless sensory feedback device for real-time gait feedback and training
    • doi:10.1109/TMECH.2012.2189014
    • Redd C.B., Bamberg S.J.M. A wireless sensory feedback device for real-time gait feedback and training. IEEE/ASME Transactions on Mechatronics 2012, 17(3):425-433. doi:10.1109/TMECH.2012.2189014.
    • (2012) IEEE/ASME Transactions on Mechatronics , vol.17 , Issue.3 , pp. 425-433
    • Redd, C.B.1    Bamberg, S.J.M.2