메뉴 건너뛰기




Volumn 7, Issue 4, 2012, Pages 361-371

Strain echocardiographic assessment of ventricular function after percutaneous pulmonary valve implantation

Author keywords

Echocardiography; Percutaneous Pulmonary Valve Implantation; Speckle Tracking; Strain

Indexed keywords

ADULT; ARTICLE; CARDIAC IMAGING; CLINICAL ARTICLE; ECHOCARDIOGRAPHY; FALLOT TETRALOGY; FEMALE; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE OUTFLOW TRACT OBSTRUCTION; HEART RIGHT VENTRICLE FUNCTION; HEART VALVE REPLACEMENT; HEART VENTRICLE SEPTUM; HEMODYNAMICS; HUMAN; LUNG ARTERY PRESSURE; LUNG SURGERY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; OUTCOME ASSESSMENT; PRIORITY JOURNAL; PULMONARY VALVE INSUFFICIENCY; RIGHT VENTRICLE TO PULMONARY ARTERY CONDUIT; SYSTOLIC BLOOD PRESSURE;

EID: 84864309595     PISSN: 1747079X     EISSN: 17470803     Source Type: Journal    
DOI: 10.1111/j.1747-0803.2012.00680.x     Document Type: Article
Times cited : (9)

References (30)
  • 1
    • 0034699902 scopus 로고    scopus 로고
    • Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction
    • Bonhoeffer P, Boudjemline Y, Saliba Z, etal. Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction. Lancet. 2000;356:1403-1405.
    • (2000) Lancet , vol.356 , pp. 1403-1405
    • Bonhoeffer, P.1    Boudjemline, Y.2    Saliba, Z.3
  • 2
    • 24044459734 scopus 로고    scopus 로고
    • Percutaneous pulmonary valve implantation in humans: results in 59 consecutive patients
    • Khambadkone S, Coats L, Taylor A, etal. Percutaneous pulmonary valve implantation in humans: results in 59 consecutive patients. Circulation. 2005;112:1189-1197.
    • (2005) Circulation , vol.112 , pp. 1189-1197
    • Khambadkone, S.1    Coats, L.2    Taylor, A.3
  • 3
    • 69449097621 scopus 로고    scopus 로고
    • Effect of transcatheter pulmonary valve implantation on short-term right ventricular function as determined by two-dimensional speckle tracking strain and strain rate imaging
    • Moiduddin N, Asoh K, Slorach C, Benson LN, Friedberg MK. Effect of transcatheter pulmonary valve implantation on short-term right ventricular function as determined by two-dimensional speckle tracking strain and strain rate imaging. Am J Cardiol. 2009;104:862-867.
    • (2009) Am J Cardiol , vol.104 , pp. 862-867
    • Moiduddin, N.1    Asoh, K.2    Slorach, C.3    Benson, L.N.4    Friedberg, M.K.5
  • 4
    • 79551529816 scopus 로고    scopus 로고
    • Early versus late functional outcome after successful percutaneous pulmonary valve implantation: are the acute effects of altered right ventricular loading all we can expect?
    • Lurz P, Nordmeyer J, Giardini A, etal. Early versus late functional outcome after successful percutaneous pulmonary valve implantation: are the acute effects of altered right ventricular loading all we can expect? J Am Coll Cardiol. 2011;57:724-731.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 724-731
    • Lurz, P.1    Nordmeyer, J.2    Giardini, A.3
  • 5
    • 46749085820 scopus 로고    scopus 로고
    • Assessment of myocardial function in pediatric patients with operated tetralogy of Fallot: preliminary results with 2D strain echocardiography
    • Knirsch W, Dodge-Khatami A, Kadner A, etal. Assessment of myocardial function in pediatric patients with operated tetralogy of Fallot: preliminary results with 2D strain echocardiography. Pediatr Cardiol. 2008;29:718-725.
    • (2008) Pediatr Cardiol , vol.29 , pp. 718-725
    • Knirsch, W.1    Dodge-Khatami, A.2    Kadner, A.3
  • 6
    • 67650863128 scopus 로고    scopus 로고
    • Tissue velocities, strain, and strain rate for echocardiographic assessment of ventricular function in congenital heart disease
    • Friedberg MK, Mertens L. Tissue velocities, strain, and strain rate for echocardiographic assessment of ventricular function in congenital heart disease. Eur J Echocardiogr. 2009;10:585-593.
    • (2009) Eur J Echocardiogr , vol.10 , pp. 585-593
    • Friedberg, M.K.1    Mertens, L.2
  • 7
    • 77955430081 scopus 로고    scopus 로고
    • Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial
    • McElhinney DB, Hellenbrand WE, Zahn EM, etal. Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial. Circulation. 2010;122:507-516.
    • (2010) Circulation , vol.122 , pp. 507-516
    • McElhinney, D.B.1    Hellenbrand, W.E.2    Zahn, E.M.3
  • 8
    • 70349996057 scopus 로고    scopus 로고
    • Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit early results from the U.S. clinical trial
    • Zahn EM, Hellenbrand WE, Lock JE, McElhinney DB. Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit early results from the U.S. clinical trial. J Am Coll Cardiol. 2009;54:1722-1729.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 1722-1729
    • Zahn, E.M.1    Hellenbrand, W.E.2    Lock, J.E.3    McElhinney, D.B.4
  • 9
    • 36248976204 scopus 로고    scopus 로고
    • Reduced and delayed untwisting of the left ventricle in patients with hypertension and left ventricular hypertrophy: a study using two-dimensional speckle tracking imaging
    • Takeuchi M, Borden WB, Nakai H, etal. Reduced and delayed untwisting of the left ventricle in patients with hypertension and left ventricular hypertrophy: a study using two-dimensional speckle tracking imaging. Eur Heart J. 2007;28:2756-2762.
    • (2007) Eur Heart J , vol.28 , pp. 2756-2762
    • Takeuchi, M.1    Borden, W.B.2    Nakai, H.3
  • 10
    • 79958090980 scopus 로고    scopus 로고
    • Evaluation of longitudinal and radial left ventricular function by two-dimensional speckle-tracking echocardiography in a large cohort of normal probands
    • Reckefuss N, Butz T, Horstkotte D, Faber L. Evaluation of longitudinal and radial left ventricular function by two-dimensional speckle-tracking echocardiography in a large cohort of normal probands. Int J Cardiovasc Imaging. 2011;27:515-526.
    • (2011) Int J Cardiovasc Imaging , vol.27 , pp. 515-526
    • Reckefuss, N.1    Butz, T.2    Horstkotte, D.3    Faber, L.4
  • 11
    • 65249115281 scopus 로고    scopus 로고
    • Echocardiographic tissue deformation imaging of right ventricular systolic function in endurance athletes
    • Teske AJ, Prakken NH, De Boeck BW, etal. Echocardiographic tissue deformation imaging of right ventricular systolic function in endurance athletes. Eur Heart J. 2009;30:969-977.
    • (2009) Eur Heart J , vol.30 , pp. 969-977
    • Teske, A.J.1    Prakken, N.H.2    De Boeck, B.W.3
  • 12
    • 77954672149 scopus 로고    scopus 로고
    • Percutaneous pulmonary valve implantation in the young 2-year follow-up
    • Vezmar M, Chaturvedi R, Lee KJ, etal. Percutaneous pulmonary valve implantation in the young 2-year follow-up. JACC Cardiovasc Interv. 2010;3:439-448.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 439-448
    • Vezmar, M.1    Chaturvedi, R.2    Lee, K.J.3
  • 13
    • 77149154025 scopus 로고    scopus 로고
    • Evaluation of right ventricular global longitudinal function in patients with tetralogy of fallot by two-dimensional ultrasound speckle tracking imaging
    • Li Y, Xie M, Wang X, etal. Evaluation of right ventricular global longitudinal function in patients with tetralogy of fallot by two-dimensional ultrasound speckle tracking imaging. J Huazhong Univ Sci Technolog Med Sci. 2010;30:126-131.
    • (2010) J Huazhong Univ Sci Technolog Med Sci , vol.30 , pp. 126-131
    • Li, Y.1    Xie, M.2    Wang, X.3
  • 14
    • 0037021552 scopus 로고    scopus 로고
    • Right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction
    • Davlouros PA, Kilner PJ, Hornung TS, etal. Right ventricular function in adults with repaired tetralogy of Fallot assessed with cardiovascular magnetic resonance imaging: detrimental role of right ventricular outflow aneurysms or akinesia and adverse right-to-left ventricular interaction. J Am Coll Cardiol. 2002;40:2044-2052.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 2044-2052
    • Davlouros, P.A.1    Kilner, P.J.2    Hornung, T.S.3
  • 15
    • 3042750194 scopus 로고    scopus 로고
    • Right ventricular strain rate and strain analysis in patients with repaired tetralogy of Fallot: possible interventricular septal compensation
    • Solarz DE, Witt SA, Glascock BJ, Jones FD, Khoury PR, Kimball TR. Right ventricular strain rate and strain analysis in patients with repaired tetralogy of Fallot: possible interventricular septal compensation. J Am Soc Echocardiogr. 2004;17:338-344.
    • (2004) J Am Soc Echocardiogr , vol.17 , pp. 338-344
    • Solarz, D.E.1    Witt, S.A.2    Glascock, B.J.3    Jones, F.D.4    Khoury, P.R.5    Kimball, T.R.6
  • 16
    • 23044489762 scopus 로고    scopus 로고
    • Global and regional left ventricular function in patients undergoing transcatheter closure of secundum atrial septal defect
    • Pascotto M, Santoro G, Caso P, etal. Global and regional left ventricular function in patients undergoing transcatheter closure of secundum atrial septal defect. Am J Cardiol. 2005;96:439-442.
    • (2005) Am J Cardiol. , vol.96 , pp. 439-442
    • Pascotto, M.1    Santoro, G.2    Caso, P.3
  • 17
    • 33746351032 scopus 로고    scopus 로고
    • Ultrasonic strain rate and strain imaging of the right ventricle in children before and after percutaneous closure of an atrial septal defect
    • Eyskens B, Ganame J, Claus P, Boshoff D, Gewillig M, Mertens L. Ultrasonic strain rate and strain imaging of the right ventricle in children before and after percutaneous closure of an atrial septal defect. J Am Soc Echocardiogr. 2006;19:994-1000.
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 994-1000
    • Eyskens, B.1    Ganame, J.2    Claus, P.3    Boshoff, D.4    Gewillig, M.5    Mertens, L.6
  • 19
    • 79551529816 scopus 로고    scopus 로고
    • Early versus late functional outcome after successful percutaneous pulmonary valve implantation: are the acute effects of altered right ventricular loading all we can expect?
    • Lurz P, Nordmeyer J, Giardini A, etal. Early versus late functional outcome after successful percutaneous pulmonary valve implantation: are the acute effects of altered right ventricular loading all we can expect? J Am Coll Cardiol. 2011;57:724-731.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 724-731
    • Lurz, P.1    Nordmeyer, J.2    Giardini, A.3
  • 20
    • 14744290104 scopus 로고    scopus 로고
    • Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repair
    • Therrien J, Provost Y, Merchant N, Williams W, Colman J, Webb G. Optimal timing for pulmonary valve replacement in adults after tetralogy of Fallot repair. Am J Cardiol. 2005;95:779-782.
    • (2005) Am J Cardiol , vol.95 , pp. 779-782
    • Therrien, J.1    Provost, Y.2    Merchant, N.3    Williams, W.4    Colman, J.5    Webb, G.6
  • 21
    • 0034332777 scopus 로고    scopus 로고
    • Pulmonary valve replacement in adults late after repair of tetralogy of fallot: are we operating too late?
    • Therrien J, Siu SC, McLaughlin PR, Liu PP, Williams WG, Webb GD. Pulmonary valve replacement in adults late after repair of tetralogy of fallot: are we operating too late? J Am Coll Cardiol. 2000;36:1670-1675.
    • (2000) J Am Coll Cardiol , vol.36 , pp. 1670-1675
    • Therrien, J.1    Siu, S.C.2    McLaughlin, P.R.3    Liu, P.P.4    Williams, W.G.5    Webb, G.D.6
  • 22
    • 77955777228 scopus 로고    scopus 로고
    • Effects of chronic severe pulmonary regurgitation and percutaneous valve repair on right ventricular geometry and contractility assessed by tissue Doppler echocardiography
    • Kjaergaard J, Iversen KK, Vejlstrup NG, etal. Effects of chronic severe pulmonary regurgitation and percutaneous valve repair on right ventricular geometry and contractility assessed by tissue Doppler echocardiography. Echocardiography. 2010;27:854-863.
    • (2010) Echocardiography , vol.27 , pp. 854-863
    • Kjaergaard, J.1    Iversen, K.K.2    Vejlstrup, N.G.3
  • 23
    • 28444440604 scopus 로고    scopus 로고
    • Aortic valve replacement for aortic insufficiency: valve type as a determinant of systolic strain recovery
    • Pomerantz BJ, Krock MD, Wollmuth JR, etal. Aortic valve replacement for aortic insufficiency: valve type as a determinant of systolic strain recovery. J Card Surg. 2005;20:524-529.
    • (2005) J Card Surg , vol.20 , pp. 524-529
    • Pomerantz, B.J.1    Krock, M.D.2    Wollmuth, J.R.3
  • 25
    • 34249308517 scopus 로고    scopus 로고
    • Impact of left ventricular loading conditions on myocardial deformation parameters: analysis of early and late changes of myocardial deformation parameters after aortic valve replacement
    • Becker M, Kramann R, Dohmen G, etal. Impact of left ventricular loading conditions on myocardial deformation parameters: analysis of early and late changes of myocardial deformation parameters after aortic valve replacement. J Am Soc Echocardiogr. 2007;20:681-689.
    • (2007) J Am Soc Echocardiogr , vol.20 , pp. 681-689
    • Becker, M.1    Kramann, R.2    Dohmen, G.3
  • 26
    • 48249156961 scopus 로고    scopus 로고
    • Utility of right ventricular tissue Doppler imaging: correlation with right heart catheterization
    • Rajagopalan N, Simon MA, Shah H, Mathier MA, Lopez-Candales A. Utility of right ventricular tissue Doppler imaging: correlation with right heart catheterization. Echocardiography. 2008;25:706-711.
    • (2008) Echocardiography , vol.25 , pp. 706-711
    • Rajagopalan, N.1    Simon, M.A.2    Shah, H.3    Mathier, M.A.4    Lopez-Candales, A.5
  • 27
    • 79951721617 scopus 로고    scopus 로고
    • A simple method to predict impaired right ventricular performance and disease severity in chronic pulmonary hypertension using strain rate imaging
    • Utsunomiya H, Nakatani S, Okada T, etal. A simple method to predict impaired right ventricular performance and disease severity in chronic pulmonary hypertension using strain rate imaging. Int J Cardiol. 2011;147:88-94.
    • (2011) Int J Cardiol , vol.147 , pp. 88-94
    • Utsunomiya, H.1    Nakatani, S.2    Okada, T.3
  • 28
    • 77957983171 scopus 로고    scopus 로고
    • Global strain rate imaging for the estimation of diastolic function in HFNEF compared with pressure-volume loop analysis
    • Kasner M, Gaub R, Sinning D, etal. Global strain rate imaging for the estimation of diastolic function in HFNEF compared with pressure-volume loop analysis. Eur J Echocardiogr. 2010;11:743-751.
    • (2010) Eur J Echocardiogr , vol.11 , pp. 743-751
    • Kasner, M.1    Gaub, R.2    Sinning, D.3
  • 29
    • 51749083262 scopus 로고    scopus 로고
    • Relation between left ventricular regional radial function and radial wall motion abnormalities using two-dimensional speckle tracking in children with idiopathic dilated cardiomyopathy
    • Friedberg MK, Slorach C. Relation between left ventricular regional radial function and radial wall motion abnormalities using two-dimensional speckle tracking in children with idiopathic dilated cardiomyopathy. Am J Cardiol. 2008;102:335-339.
    • (2008) Am J Cardiol , vol.102 , pp. 335-339
    • Friedberg, M.K.1    Slorach, C.2
  • 30
    • 79951887922 scopus 로고    scopus 로고
    • Current and evolving echocardiographic techniques for the quantitative evaluation of cardiac mechanics: ASE/EAE consensus statement on methodology and indications endorsed by the Japanese Society of Echocardiography
    • Mor-Avi V, Lang RM, Badano LP, etal. Current and evolving echocardiographic techniques for the quantitative evaluation of cardiac mechanics: ASE/EAE consensus statement on methodology and indications endorsed by the Japanese Society of Echocardiography. J Am Soc Echocardiogr. 2011;24:277-313.
    • (2011) J Am Soc Echocardiogr , vol.24 , pp. 277-313
    • Mor-Avi, V.1    Lang, R.M.2    Badano, L.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.