-
1
-
-
12844258855
-
Extracorporeal life support registry report 2004
-
DOI 10.1097/01.MAT.0000151922.67540.E9
-
Conrad SA, Rycus PT, Dalton H: Extracorporeal Life Support registry report 2004. ASAIO J 2005; 51:4-10 (Pubitemid 40165243)
-
(2005)
ASAIO Journal
, vol.51
, Issue.1
, pp. 4-10
-
-
Conrad, S.A.1
Rycus, P.T.2
Dalton, H.3
-
2
-
-
16544389700
-
Extracorporeal life support in pediatric and neonatal critical care: A review
-
Lequier L: Extracorporeal life support in pediatric and neonatal critical care: A review.J Intensive Care Med 2004; 19:243-258
-
(2004)
J Intensive Care Med
, vol.19
, pp. 243-258
-
-
Lequier, L.1
-
3
-
-
0034520271
-
The Current status of neonatal extracorporeal membrane oxygenation
-
Rais-Bahrami K, Short BL: The current status of neonatal extracorporeal membrane oxygenation. Semin Perinatol 2000; 24:406-417 (Pubitemid 32039054)
-
(2000)
Seminars in Perinatology
, vol.24
, Issue.6
, pp. 406-417
-
-
Rais-Bahrami, K.1
Short, B.L.2
-
4
-
-
79251582744
-
Extracorporeal membrane oxygenation for pediatric respiratory failure: Survival and predictors of mortality
-
Zabrocki LA, Brogan TV, Statler KD, et al: Extracorporeal membrane oxygenation for pediatric respiratory failure: Survival and predictors of mortality. Crit Care Med 39:364-370
-
Crit Care Med
, vol.39
, pp. 364-370
-
-
Zabrocki, L.A.1
Brogan, T.V.2
Statler, K.D.3
-
5
-
-
33646851394
-
United Kingdom collaborative randomized trial of neonatal extracorporeal membrane oxygenation: Follow-up to age 7 years
-
DOI 10.1542/peds.2005-1167
-
McNally H, Bennett CC, Elbourne D, et al: United Kingdom collaborative randomized rial of neonatal extracorporeal membrane oxygenation: Follow-up to age 7 years. Pediatrics 2006; 117:e845-e854 (Pubitemid 46071351)
-
(2006)
Pediatrics
, vol.117
, Issue.5
-
-
McNally, H.1
Bennett, C.C.2
Elbourne, D.3
Field, D.J.4
-
6
-
-
70350018319
-
Efficacy and economic assessment of conventional ventilatory support versus extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR): A multicentre randomised controlled trial
-
Peek GJ, Mugford M, Tiruvoipati R, et al: Efficacy and economic assessment of conventional ventilatory support versus extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR): A multicentre randomised controlled trial. Lancet2009; 374:1351-1363
-
(2009)
Lancet
, vol.374
, pp. 1351-1363
-
-
Peek, G.J.1
Mugford, M.2
Tiruvoipati, R.3
-
7
-
-
35148884316
-
Extracorporeal membrane oxygenation to aid cardiopulmonary resuscitation in infants and children
-
DOI 10.1161/CIRCULATIONAHA.106.680678
-
Thiagarajan RR, Laussen PC, Rycus PT, et al: Extracorporeal membrane oxygenation to aid cardiopulmonary resuscitation in infants and children. Circulation 2007; 116:1693-1700 (Pubitemid 47537843)
-
(2007)
Circulation
, vol.116
, Issue.15
, pp. 1693-1700
-
-
Thiagarajan, R.R.1
Laussen, P.C.2
Rycus, P.T.3
Bartlett, R.H.4
Bratton, S.L.5
-
8
-
-
56149127191
-
North American neonatal extracorporeal membrane oxygenation (ECMO) devices and team roles: 2008 survey results of Extracorporeal Life Support Organization (ELSO) centers
-
Lawson DS, Lawson AF, Walczak R, et al: North American neonatal extracorporeal membrane oxygenation (ECMO) devices and team roles: 2008 survey results of Extracorporeal Life Support Organization (ELSO) centers. J Extra Corpor Technol 2008; 40:166-174
-
(2008)
J Extra Corpor Technol
, vol.40
, pp. 166-174
-
-
Lawson, D.S.1
Lawson, A.F.2
Walczak, R.3
-
9
-
-
59849101804
-
Significance of hemolysis on extracorporeal life support after cardiac surgery in children
-
Gbadegesin R, Zhao S, Charpie J, et al: Significance of hemolysis on extracorporeal life support after cardiac surgery in children. Pediatr Nephrol 2009; 24:589-595
-
(2009)
Pediatr Nephrol
, vol.24
, pp. 589-595
-
-
Gbadegesin, R.1
Zhao, S.2
Charpie, J.3
-
10
-
-
0024419491
-
Hemolysis during long-term extracorporeal membrane oxygenation
-
Steinhorn RH, Isham-Schopf B, Smith C, et al:Hemolysis during long-term extracorporeal membrane oxygenation. J Pediatr 1989; 115:625-630 (Pubitemid 19248848)
-
(1989)
Journal of Pediatrics
, vol.115
, Issue.4
, pp. 625-630
-
-
Steinhorn, R.H.1
Isham-Schopf, B.2
Smith, C.3
Green, T.P.4
-
11
-
-
34249862077
-
Increased hemolysis from saline pre-washing RBCs or centrifugal pumps in neonatal ECMO
-
DOI 10.1038/sj.jp.7211748, PII 7211748
-
Masalunga C, Cruz M, Porter B, et al: Increased hemolysis from saline pre-washing RBCs or centrifugal pumps in neonatal ECMO. J Perinatol 2007; 27:380-384 (Pubitemid 46860533)
-
(2007)
Journal of Perinatology
, vol.27
, Issue.6
, pp. 380-384
-
-
Masalunga, C.1
Cruz, M.2
Porter, B.3
Roseff, S.4
Chui, B.5
Mainali, E.6
-
12
-
-
0029925274
-
Can clinical parameters help reliably predict the onset of acute intracranial hemorrhage in infants receiving extracorporeal membrane oxygenation?
-
De Sanctis JT, Bramson RT, Blickman JG: Can clinical parameters help reliably predict the onsetof acute intracranial hemorrhage in infants receiving extracorporeal membrane oxygenation? Radiology 1996; 199:429-432 (Pubitemid 26121989)
-
(1996)
Radiology
, vol.199
, Issue.2
, pp. 429-432
-
-
De Sanctis, J.T.1
Bramson, R.T.2
Blickman, J.G.3
-
13
-
-
79952201981
-
Laboratory and clinical predictors of thrombosis and hemorrhage in 29 pediatric extracorporeal membrane oxygenation nonsurvivors
-
Reed RC, Rutledge JC: Laboratory and clinical predictors of thrombosis and hemorrhage in 29 pediatric extracorporeal membrane oxygenation nonsurvivors. Pediatr Dev Pathol 2010; 13:385-392
-
(2010)
Pediatr Dev Pathol
, vol.13
, pp. 385-392
-
-
Reed, R.C.1
Rutledge, J.C.2
-
14
-
-
0035985404
-
In vitro comparison of blood pump induced platelet microaggregates between a centrifugal and roller pump during cardiopulmonary bypass
-
Linneweber J, Chow TW, Kawamura M, et al: In vitro comparison of blood pump induced plateletmicroaggregates between a centrifugal and roller pump during cardiopulmonary bypass. Int J Artif Organs 2002; 25:549-555 (Pubitemid 34830523)
-
(2002)
International Journal of Artificial Organs
, vol.25
, Issue.6
, pp. 549-555
-
-
Linneweber, J.1
Chow, T.W.2
Kawamura, M.3
Moake, J.L.4
Nose, Y.5
-
15
-
-
0030018138
-
Comparison of centrifugal and roller pump hemolysis rates at low flow
-
Moon YS, Ohtsubo S, Gomez MR, et al: Comparison of centrifugal and roller pump hemolysis rates at low flow. Artif Organs 1996; 20:579-581 (Pubitemid 26246667)
-
(1996)
Artificial Organs
, vol.20
, Issue.6
, pp. 579-581
-
-
Moon, Y.S.1
Ohtsubo, S.2
Gomez, M.R.3
Moon, J.K.4
Nose, Y.5
-
16
-
-
0035085776
-
Hemolysis and hematology profile during perfusion: Inter-species comparison
-
Mueller XM, Tevaearai HT, Jegger D, et al: Hemolysis and hematology profile during perfusion: Inter-species comparison. Int J Artif Organs 2001; 24:89-94 (Pubitemid 32243608)
-
(2001)
International Journal of Artificial Organs
, vol.24
, Issue.2
, pp. 89-94
-
-
Mueller, X.M.1
Tevaearai, H.T.2
Jegger, D.3
Tucker, O.4
Von Segesser, L.K.5
-
17
-
-
1442276354
-
Antibodies against human cell receptors, CD36, CD41a, and CD62P crossreact with porcine platelets
-
Delgado AV, Alexander SL, McManus AT, et al: Antibodies against human cell receptors, CD36, CD41a, and CD62P crossreact with porcine platelets. Cytometry B Clin Cytom 2003; 56:62-67 (Pubitemid 38292617)
-
(2003)
Cytometry Part B - Clinical Cytometry
, vol.56
, Issue.1
, pp. 62-67
-
-
Delgado, A.V.1
Alexander, S.L.2
McManus, A.T.3
Pusateri, A.E.4
-
18
-
-
0343488539
-
A dynamic method for setting roller pumps nonocclusively reduces hemolysis and predicts retrograde flow
-
DOI 10.1097/00002480-199701000-00009
-
Tamari Y, Lee-Sensiba K, Leonard EF, et al: A dynamic method for setting roller pumps nonocclusively reduces hemolysis and predicts retrograde flow. ASAIO J 1997; 43:39-52 (Pubitemid 27074749)
-
(1997)
ASAIO Journal
, vol.43
, Issue.1
, pp. 39-52
-
-
Tamari, Y.1
Lee-Sensiba, K.2
Leonard, E.F.3
Tortolani, A.J.4
-
19
-
-
0025457147
-
Maximum blood flow rates for arterial cannulae used in neonatal ECMO
-
Van Meurs KP, Mikesell GT, Seale WR, et al: Maximum blood flow rates for arterial cannulae used in neonatal ECMO. ASAIO Transs 1990; 36:M679-M681 (Pubitemid 20367165)
-
(1990)
ASAIO Transactions
, vol.36
, Issue.3
-
-
Van Meurs, K.P.1
Mikesell, G.T.2
Seale, W.R.3
Short, B.L.4
Rivera, O.5
-
21
-
-
0031474786
-
Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices
-
Malinauskas RA: Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices. Artif Organs 1997; 21:1255-1267 (Pubitemid 28060169)
-
(1997)
Artificial Organs
, vol.21
, Issue.12
, pp. 1255-1267
-
-
Malinauskas, R.A.1
-
23
-
-
0028941568
-
Flow cytometric studies of plateletresponses to shear stress in whole blood
-
Konstantopoulos K, Wu KK, Udden MM, et al: Flow cytometric studies of plateletresponses to shear stress in whole blood. Biorheology 1995; 32:73-93
-
(1995)
Biorheology
, vol.32
, pp. 73-93
-
-
Konstantopoulos, K.1
Wu, K.K.2
Udden, M.M.3
-
24
-
-
0030972863
-
Characterization of the porcine homologue to human platelet glycoprotein IIb-IIIa (CD41/CD61) by a monoclonal antibody
-
Perez de la Lastra JM, Moreno A, Perez J, et al: Characterization of the porcine homologue to human plateletglycoprotein IIb-IIIa (CD41/CD61) by a monoclonal antibody. Tissue Antigens 1997; 49:588-594 (Pubitemid 27267879)
-
(1997)
Tissue Antigens
, vol.49
, Issue.6
, pp. 588-594
-
-
Perez De La Lastra, J.M.1
Moreno, A.2
Perez, J.3
Llanes, D.4
-
25
-
-
70349294434
-
Neurological injury after extracorporeal membrane oxygenation use to aid pediatric cardiopulmonary resuscitation
-
Barrett CS, Bratton SL, Salvin JW, et al: Neurological injury after extracorporeal membrane oxygenation use to aid pediatric cardiopulmonary resuscitation. Pediatr Crit Care Med 2009; 10:445-451
-
(2009)
Pediatr Crit Care Med
, vol.10
, pp. 445-451
-
-
Barrett, C.S.1
Bratton, S.L.2
Salvin, J.W.3
-
26
-
-
0026239690
-
Comparison of pressure-volume-flow relationships in centrifugal and roller pump extracorporeal membrane oxygenation systems for neonates
-
Green TP, Kriesmer P, Steinhorn RH, et al: Comparison of pressure-volume-flow relationships in centrifugal and roller pump extracorporeal membrane oxygenation systems for neonates. ASAIO Trans 1991; 37:572-576
-
(1991)
ASAIO Trans
, vol.37
, pp. 572-576
-
-
Green, T.P.1
Kriesmer, P.2
Steinhorn, R.H.3
-
27
-
-
0036841624
-
Hemolytic characteristics of oxygenators during clinical extracorporeal membrane oxygenation
-
Kawahito S, Maeda T, Motomura T, et al: Hemolytic characteristics of oxygenators during clinical extracorporeal membrane oxygenation. ASAIO J 2002; 48:636-639 (Pubitemid 35285516)
-
(2002)
ASAIO Journal
, vol.48
, Issue.6
, pp. 636-639
-
-
Kawahito, S.1
Maeda, T.2
Motomura, T.3
Ishitoya, H.4
Takano, T.5
Nonaka, K.6
Linneweber, J.7
Ichikawa, S.8
Kawamura, M.9
Hanazaki, K.10
Glueck, J.11
Nose, Y.12
-
28
-
-
15944398355
-
The clinical sequelae of intravascular hemolysis and extracellular plasma hemoglobin: A novel mechanism of human disease
-
DOI 10.1001/jama.293.13.1653
-
Rother RP, Bell L, Hillmen P, et al: The clinical sequelae of intravascular hemolysis and extracellular plasma hemoglobin: A novel mechanism of human disease. JAMA 2005; 293:1653-1662 (Pubitemid 40471796)
-
(2005)
Journal of the American Medical Association
, vol.293
, Issue.13
, pp. 1653-1662
-
-
Rother, R.P.1
Bell, L.2
Hillmen, P.3
Gladwin, M.T.4
-
29
-
-
62449196644
-
Extracorporeal Life Support registry report 2008 Neonatal and pediatric cardiac cases
-
Haines NM, Rycus PT, Zwischenberger JB, et al: Extracorporeal Life Support registry report 2008: Neonatal and pediatric cardiac cases. ASAIO J 2009; 55:111-116
-
(2009)
ASAIO J
, vol.55
, pp. 111-116
-
-
Haines, N.M.1
Rycus, P.T.2
Zwischenberger, J.B.3
-
30
-
-
0028324840
-
Complications of neonatal extracorporeal membrane oxygenation. Collective experience from the extracorporeal life support organization
-
discussion 848-849
-
Zwischenberger JB, Nguyen TT, Upp JR Jr, et al: Complications of neonatal extracorporeal membrane oxygenation. Collective experience from the Extracorporeal Life Support Organization. J Thorac Cardiovasc Surg 1994; 107:838-848; discussion 848-849
-
(1994)
J Thorac Cardiovasc Surg
, vol.107
, pp. 838-848
-
-
Zwischenberger, J.B.1
Nguyen, T.T.2
Upp Jr., J.R.3
-
31
-
-
0027993741
-
The significant relationship between platelet count and haemorrhagic complications on ECMO
-
Stallion A, Cofer BR, Rafferty JA, et al: The significant relationship between plateletcount and haemorrhagic complications on ECMO. Perfusion 1994; 9:265-269 (Pubitemid 24255379)
-
(1994)
Perfusion
, vol.9
, Issue.4
, pp. 265-269
-
-
Stallion, A.1
Cofer, B.R.2
Rafferty, J.A.3
Ziegler, M.M.4
Ryckman, F.C.5
-
32
-
-
0026580285
-
Coagulation parameter instability as an early predictor of intracranial hemorrhage during extracorporeal membrane oxygenation
-
Hirthler MA, Blackwell E, Abbe D, et al: Coagulation parameter instability as an early predictor of intracranial hemorrhage during extracorporeal membrane oxygenation. J Pediatr Surg 1992; 27:40-43
-
(1992)
J Pediatr Surg
, vol.27
, pp. 40-43
-
-
Hirthler, M.A.1
Blackwell, E.2
Abbe, D.3
-
33
-
-
0030642315
-
Risk factors for intracranial hemorrhage in the extracorporeal membrane oxygenation patient
-
Dela Cruz TV, Stewart DL, Winston SJ, et al: Risk factors for intracranial hemorrhage in the extracorporeal membrane oxygenation patient. J Perinatol 1997; 17:18-23 (Pubitemid 127452396)
-
(1997)
Journal of Perinatology
, vol.17
, Issue.1
, pp. 18-23
-
-
Dela Cruz, T.V.1
Stewart, D.L.2
Winston, S.J.3
Weatherman, K.S.4
Phelps, J.L.5
Mendoza, J.C.6
-
34
-
-
0036593165
-
Multicenter analysis of platelettransfusion usage among neonates on extracorporeal membrane oxygenation
-
Chevuru SC, Sola MC, Theriaque DW, et al: Multicenter analysis of platelettransfusion usage among neonates on extracorporeal membrane oxygenation. Pediatrics 2002; 109:e89
-
(2002)
Pediatrics
, vol.109
-
-
Chevuru, S.C.1
Sola, M.C.2
Theriaque, D.W.3
-
35
-
-
0033852546
-
The mechanisms of platelet dysfunction during extracorporeal membrane oxygenation in critically ill neonates
-
Cheung PY, Sawicki G, Salas E, et al: The mechanisms of plateletdysfunction during extracorporeal membrane oxygenation in critically ill neonates. Crit Care Med 2000; 28:2584-2590 (Pubitemid 30604474)
-
(2000)
Critical Care Medicine
, vol.28
, Issue.7
, pp. 2584-2590
-
-
Cheung, P.-Y.1
Sawicki, G.2
Salas, E.3
Etches, P.C.4
Schulz, R.5
Radomski, M.W.6
-
36
-
-
0027310437
-
The plateletfunction defect of cardiopulmonary bypass
-
Kestin AS, Valeri CR, Khuri SF, et al: The plateletfunction defect of cardiopulmonary bypass. Blood 1993; 82:107-117
-
(1993)
Blood
, vol.82
, pp. 107-117
-
-
Kestin, A.S.1
Valeri, C.R.2
Khuri, S.F.3
-
37
-
-
0032460111
-
The plateletin cardiopulmonary bypass
-
Weerasinghe A, Taylor KM: The plateletin cardiopulmonary bypass. Ann Thorac Surg 1998; 66:2145-2152
-
(1998)
Ann Thorac Surg
, vol.66
, pp. 2145-2152
-
-
Weerasinghe, A.1
Taylor, K.M.2
-
38
-
-
42049098604
-
Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation
-
DOI 10.1177/0267659107086270
-
Thiara AP, Hoel TN, Kristiansen F, et al: Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation. Perfusion 2007; 22:323-326 (Pubitemid 351516043)
-
(2007)
Perfusion
, vol.22
, Issue.5
, pp. 323-326
-
-
Thiara, A.P.S.1
Hoel, T.N.2
Kristianson, F.3
Karlsen, H.M.4
Fiane, A.E.5
Svennevig, J.L.6
-
39
-
-
24944567494
-
Hemolytic characteristics of three commercially available centrifugal blood pumps
-
DOI 10.1097/01.PCC.0000163282.63992.13
-
Lawson DS, Ing R, Cheifetz IM, et al: Hemolytic characteristics of three commercially available centrifugal blood pumps. Pediatr Crit Care Med 2005; 6:573-577 (Pubitemid 41306761)
-
(2005)
Pediatric Critical Care Medicine
, vol.6
, Issue.5
, pp. 573-577
-
-
Lawson, D.S.1
Ing, R.2
Cheifetz, I.M.3
Walczak, R.4
Craig, D.5
Schulman, S.6
Kern, F.7
Shearer, I.R.8
Lodge, A.9
Jaggers, J.10
-
40
-
-
18744384321
-
Extracorporeal membrane oxygenator compatible with centrifugal blood pumps
-
DOI 10.1046/j.1525-1594.2002.07117.x
-
Motomura T, Maeda T, Kawahito S, et al: Extracorporeal membrane oxygenator compatible with centrifugal blood pumps. Artif Organs 2002; 26:952-958 (Pubitemid 35334923)
-
(2002)
Artificial Organs
, vol.26
, Issue.11
, pp. 952-958
-
-
Motomura, T.1
Maeda, T.2
Kawahito, S.3
Matsui, T.4
Ichikawa, S.5
Ishitoya, H.6
Kawamura, M.7
Nishimura, I.8
Shinohara, T.9
Oestmann, D.10
Glueck, J.11
Kawaguchi, Y.12
Sato, K.13
Nose, Y.14
-
41
-
-
79960279415
-
Clinical evaluation of two different extracorporeal membrane oxygenation systems: A single center report
-
Yu K, Long C, Hei F, et al: Clinical evaluation of two different extracorporeal membrane oxygenation systems: A single center report. Artif Organs 2011; 35:733-737
-
(2011)
Artif Organs
, vol.35
, pp. 733-737
-
-
Yu, K.1
Long, C.2
Hei, F.3
-
42
-
-
1642407635
-
D oxygenator for ECMO
-
DOI 10.1191/0267659104pf702oa
-
Horton S, Thuys C, Bennett M, et al: Experience with the Jostra Rotaflow and QuadroxD oxygenator for ECMO. Perfusion 2004; 19:17-23 (Pubitemid 38386645)
-
(2004)
Perfusion
, vol.19
, Issue.1
, pp. 17-23
-
-
Horton, S.1
Thuys, C.2
Bennett, M.3
Augustin, S.4
Rosenberg, M.5
Brizard, C.6
|