메뉴 건너뛰기




Volumn 215, Issue 2, 2012, Pages

Three-dimensional staining of liver segments with an ultrasound contrast agent as an aid to anatomic liver resection

Author keywords

[No Author keywords available]

Indexed keywords

INDIGO CARMINE; PERFLUBUTANE;

EID: 84864277044     PISSN: 10727515     EISSN: 18791190     Source Type: Journal    
DOI: 10.1016/j.jamcollsurg.2012.05.017     Document Type: Article
Times cited : (17)

References (26)
  • 1
    • 22744451196 scopus 로고    scopus 로고
    • Prognostic impact of anatomic resection for hepatocellular carcinoma
    • K. Hasegawa, N. Kokudo, H. Imamura Prognostic impact of anatomic resection for hepatocellular carcinoma Ann Surg 242 2005 252 259
    • (2005) Ann Surg , vol.242 , pp. 252-259
    • Hasegawa, K.1    Kokudo, N.2    Imamura, H.3
  • 2
    • 0032784523 scopus 로고    scopus 로고
    • Prognostic significance of anatomical resection and des-gamma-carboxy prothrombin in patients with hepatocellular carcinoma
    • H. Imamura, Y. Matsuyama, Y. Miyagawa Prognostic significance of anatomical resection and des-gamma-carboxy prothrombin in patients with hepatocellular carcinoma Br J Surg 86 1999 1032 1038
    • (1999) Br J Surg , vol.86 , pp. 1032-1038
    • Imamura, H.1    Matsuyama, Y.2    Miyagawa, Y.3
  • 3
    • 82455212295 scopus 로고    scopus 로고
    • Significance of anatomic resection for early and advanced hepatocellular carcinoma
    • Y. Kishi, A. Saiura, J. Yamamoto Significance of anatomic resection for early and advanced hepatocellular carcinoma Langenbecks Arch Surg 397 2012 85 92
    • (2012) Langenbecks Arch Surg , vol.397 , pp. 85-92
    • Kishi, Y.1    Saiura, A.2    Yamamoto, J.3
  • 4
    • 60149095308 scopus 로고    scopus 로고
    • Surgical contribution to recurrence-free survival in patients with macrovascular-invasion-negative hepatocellular carcinoma
    • S. Tanaka, K. Mogushi, M. Yasen Surgical contribution to recurrence-free survival in patients with macrovascular-invasion-negative hepatocellular carcinoma J Am Coll Surg 208 2009 368 374
    • (2009) J Am Coll Surg , vol.208 , pp. 368-374
    • Tanaka, S.1    Mogushi, K.2    Yasen, M.3
  • 5
    • 53549105528 scopus 로고    scopus 로고
    • Efficacy of anatomic resection vs nonanatomic resection for small nodular hepatocellular carcinoma based on gross classification
    • S. Ueno, F. Kubo, M. Sakoda Efficacy of anatomic resection vs nonanatomic resection for small nodular hepatocellular carcinoma based on gross classification J Hepatobiliary Pancreat Surg 15 2008 493 500
    • (2008) J Hepatobiliary Pancreat Surg , vol.15 , pp. 493-500
    • Ueno, S.1    Kubo, F.2    Sakoda, M.3
  • 6
    • 80052851883 scopus 로고    scopus 로고
    • Meta-analysis of anatomic resection versus nonanatomic resection for hepatocellular carcinoma
    • Y. Zhou, D. Xu, L. Wu, B. Li Meta-analysis of anatomic resection versus nonanatomic resection for hepatocellular carcinoma Langenbecks Arch Surg 396 2011 1109 1117
    • (2011) Langenbecks Arch Surg , vol.396 , pp. 1109-1117
    • Zhou, Y.1    Xu, D.2    Wu, L.3    Li, B.4
  • 7
    • 77955897618 scopus 로고    scopus 로고
    • Comparison of the outcomes between anatomical resection and limited resection for single hepatocellular carcinomas no larger than 5 cm in diameter: A single-center study
    • O. Yamazaki, M. Matsuyama, K. Horii Comparison of the outcomes between anatomical resection and limited resection for single hepatocellular carcinomas no larger than 5 cm in diameter: a single-center study J Hepatobiliary Pancreat Sci 17 2010 349 358
    • (2010) J Hepatobiliary Pancreat Sci , vol.17 , pp. 349-358
    • Yamazaki, O.1    Matsuyama, M.2    Horii, K.3
  • 8
    • 0020976339 scopus 로고
    • Intraoperative ultrasonic examination for hepatectomy
    • M. Makuuchi, H. Hasegawa, S. Yamazaki Intraoperative ultrasonic examination for hepatectomy Ultrasound Med Biol Suppl 2 1983 493 497
    • (1983) Ultrasound Med Biol , Issue.SUPPL. 2 , pp. 493-497
    • Makuuchi, M.1    Hasegawa, H.2    Yamazaki, S.3
  • 10
    • 0026062544 scopus 로고
    • A new method for mapping hepatic subsegment: Counterstaining identification technique
    • T. Takayama, M. Makuuchi, K. Watanabe A new method for mapping hepatic subsegment: counterstaining identification technique Surgery 109 1991 226 229
    • (1991) Surgery , vol.109 , pp. 226-229
    • Takayama, T.1    Makuuchi, M.2    Watanabe, K.3
  • 11
    • 0029787455 scopus 로고    scopus 로고
    • Segmental anatomy of the liver under the right diaphragmatic dome: Evaluation with axial CT
    • I. Ohashi, H. Ina, Y. Okada Segmental anatomy of the liver under the right diaphragmatic dome: evaluation with axial CT Radiology 200 1996 779 783
    • (1996) Radiology , vol.200 , pp. 779-783
    • Ohashi, I.1    Ina, H.2    Okada, Y.3
  • 12
    • 77951666049 scopus 로고    scopus 로고
    • The intersegmental plane of the liver is not always flat-tricks for anatomical liver resection
    • J. Shindoh, Y. Mise, S. Satou The intersegmental plane of the liver is not always flat-tricks for anatomical liver resection Ann Surg 251 2010 917 922
    • (2010) Ann Surg , vol.251 , pp. 917-922
    • Shindoh, J.1    Mise, Y.2    Satou, S.3
  • 13
    • 0028605996 scopus 로고
    • Portal venous and segmental anatomy of the right hemiliver: Observations based on three-dimensional spiral CT renderings
    • M.S. van Leeuwen, J. Noordzij, M.A. Fernandez Portal venous and segmental anatomy of the right hemiliver: observations based on three-dimensional spiral CT renderings AJR Am J Roentgenol 163 1994 1395 1404
    • (1994) AJR Am J Roentgenol , vol.163 , pp. 1395-1404
    • Van Leeuwen, M.S.1    Noordzij, J.2    Fernandez, M.A.3
  • 14
    • 48549097280 scopus 로고    scopus 로고
    • Image-guided liver mapping using fluorescence navigation system with indocyanine green for anatomical hepatic resection
    • T. Aoki, D. Yasuda, Y. Shimizu Image-guided liver mapping using fluorescence navigation system with indocyanine green for anatomical hepatic resection World J Surg 32 2008 1763 1767
    • (2008) World J Surg , vol.32 , pp. 1763-1767
    • Aoki, T.1    Yasuda, D.2    Shimizu, Y.3
  • 15
    • 80052860585 scopus 로고    scopus 로고
    • Combined intraoperative use of contrast-enhanced ultrasonography imaging using a sonazoid and fluorescence navigation system with indocyanine green during anatomical hepatectomy
    • K. Uchiyama, M. Ueno, S. Ozawa Combined intraoperative use of contrast-enhanced ultrasonography imaging using a sonazoid and fluorescence navigation system with indocyanine green during anatomical hepatectomy Langenbecks Arch Surg 396 2011 1101 1107
    • (2011) Langenbecks Arch Surg , vol.396 , pp. 1101-1107
    • Uchiyama, K.1    Ueno, M.2    Ozawa, S.3
  • 16
    • 34247859143 scopus 로고    scopus 로고
    • Three-dimensional visualization of liver segments on contrast-enhanced intraoperative sonography
    • J. Arita, N. Kokudo, K. Zhang, M. Makuuchi Three-dimensional visualization of liver segments on contrast-enhanced intraoperative sonography AJR Am J Roentgenol 188 2007 W464 W466
    • (2007) AJR Am J Roentgenol , vol.188
    • Arita, J.1    Kokudo, N.2    Zhang, K.3    Makuuchi, M.4
  • 17
    • 67349230291 scopus 로고    scopus 로고
    • Microbubble stability is a major determinant of the efficiency of ultrasound and microbubble mediated in vivo gene transfer
    • J. Alter, C.A. Sennoga, D.M. Lopes Microbubble stability is a major determinant of the efficiency of ultrasound and microbubble mediated in vivo gene transfer Ultrasound Med Biol 35 2009 976 984
    • (2009) Ultrasound Med Biol , vol.35 , pp. 976-984
    • Alter, J.1    Sennoga, C.A.2    Lopes, D.M.3
  • 18
    • 42949135386 scopus 로고    scopus 로고
    • Physicochemical characteristics of Sonazoid, a new contrast agent for ultrasound imaging
    • P.C. Sontum Physicochemical characteristics of Sonazoid, a new contrast agent for ultrasound imaging Ultrasound Med Biol 34 2008 824 833
    • (2008) Ultrasound Med Biol , vol.34 , pp. 824-833
    • Sontum, P.C.1
  • 19
    • 84855321338 scopus 로고    scopus 로고
    • Usefulness of combination of imaging modalities in the diagnosis of hepatocellular carcinoma using Sonazoid(R)-enhanced ultrasound, gadolinium diethylene-triamine-pentaacetic acid-enhanced magnetic resonance imaging, and contrast-enhanced computed tomography
    • A. Alaboudy, T. Inoue, K. Hatanaka Usefulness of combination of imaging modalities in the diagnosis of hepatocellular carcinoma using Sonazoid(R)-enhanced ultrasound, gadolinium diethylene-triamine-pentaacetic acid-enhanced magnetic resonance imaging, and contrast-enhanced computed tomography Oncology 81 Suppl 1 2011 66 72
    • (2011) Oncology , vol.81 , Issue.SUPPL. 1 , pp. 66-72
    • Alaboudy, A.1    Inoue, T.2    Hatanaka, K.3
  • 20
    • 79960519514 scopus 로고    scopus 로고
    • Correlation between contrast-enhanced intraoperative ultrasound using Sonazoid and histologic grade of resected hepatocellular carcinoma
    • J. Arita, K. Hasegawa, M. Takahashi Correlation between contrast-enhanced intraoperative ultrasound using Sonazoid and histologic grade of resected hepatocellular carcinoma AJR Am J Roentgenol 196 2011 1314 1321
    • (2011) AJR Am J Roentgenol , vol.196 , pp. 1314-1321
    • Arita, J.1    Hasegawa, K.2    Takahashi, M.3
  • 21
    • 81855170302 scopus 로고    scopus 로고
    • Usefulness of contrast-enhanced intraoperative ultrasound using Sonazoid in patients with hepatocellular carcinoma
    • J. Arita, M. Takahashi, S. Hata Usefulness of contrast-enhanced intraoperative ultrasound using Sonazoid in patients with hepatocellular carcinoma Ann Surg 254 2011 992 999
    • (2011) Ann Surg , vol.254 , pp. 992-999
    • Arita, J.1    Takahashi, M.2    Hata, S.3
  • 22
    • 80052686690 scopus 로고    scopus 로고
    • Contrast enhanced ultrasound in the detection of liver metastases: A prospective multi-centre dose testing study using a perfluorobutane microbubble contrast agent (NC100100)
    • J.M. Correas, G. Low, L. Needleman Contrast enhanced ultrasound in the detection of liver metastases: a prospective multi-centre dose testing study using a perfluorobutane microbubble contrast agent (NC100100) Eur Radiol 21 2011 1739 1746
    • (2011) Eur Radiol , vol.21 , pp. 1739-1746
    • Correas, J.M.1    Low, G.2    Needleman, L.3
  • 23
    • 58149095546 scopus 로고    scopus 로고
    • Imaging of hepatocellular carcinoma: Qualitative and quantitative analysis of postvascular phase contrast-enhanced ultrasonography with sonazoid Comparison with superparamagnetic iron oxide magnetic resonance images
    • T. Inoue, M. Kudo, K. Hatanaka Imaging of hepatocellular carcinoma: qualitative and quantitative analysis of postvascular phase contrast-enhanced ultrasonography with sonazoid Comparison with superparamagnetic iron oxide magnetic resonance images Oncology 75 Suppl 1 2008 48 54
    • (2008) Oncology , vol.75 , Issue.SUPPL. 1 , pp. 48-54
    • Inoue, T.1    Kudo, M.2    Hatanaka, K.3
  • 24
    • 84855317655 scopus 로고    scopus 로고
    • Diagnostic imaging of hepatocellular carcinoma: Recent progress
    • M. Kudo Diagnostic imaging of hepatocellular carcinoma: recent progress Oncology 81 Suppl 1 2011 73 85
    • (2011) Oncology , vol.81 , Issue.SUPPL. 1 , pp. 73-85
    • Kudo, M.1
  • 25
    • 77954518596 scopus 로고    scopus 로고
    • Newly developed novel ultrasound technique, defect reperfusion ultrasound imaging, using sonazoid in the management of hepatocellular carcinoma
    • M. Kudo, K. Hatanaka, K. Maekawa Newly developed novel ultrasound technique, defect reperfusion ultrasound imaging, using sonazoid in the management of hepatocellular carcinoma Oncology 78 Suppl 1 2010 40 45
    • (2010) Oncology , vol.78 , Issue.SUPPL. 1 , pp. 40-45
    • Kudo, M.1    Hatanaka, K.2    Maekawa, K.3
  • 26
    • 84864271262 scopus 로고    scopus 로고
    • Comparison of Kupffer-phase Sonazoid-enhanced sonography and hepatobiliary-phase gadoxetic acid-enhanced magnetic resonance imaging of hepatocellular carcinoma and correlation with histologic grading
    • K. Sugimoto, F. Moriyasu, K. Saito Comparison of Kupffer-phase Sonazoid-enhanced sonography and hepatobiliary-phase gadoxetic acid-enhanced magnetic resonance imaging of hepatocellular carcinoma and correlation with histologic grading J Ultrasound Med 31 2012 529 538
    • (2012) J Ultrasound Med , vol.31 , pp. 529-538
    • Sugimoto, K.1    Moriyasu, F.2    Saito, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.