메뉴 건너뛰기




Volumn , Issue , 2012, Pages 1938-1943

Versatile infrared gas measurement system with tunable microstructured Fabry-Pérot Filter

Author keywords

Fabry P rot filter (FPF); Gas analysis; Infrared transmission spectroscopy (IRTS); photoacoustic absorption spectroscopy (PAS)

Indexed keywords

APPLICATION SCENARIO; BREATH TESTS; CONCENTRATION RANGES; CONDENSER MICROPHONE; GAS CHAMBERS; GAS CONCENTRATION; HIGH CONCENTRATION; INFRARED TRANSMISSION SPECTROSCOPY; IR SOURCE; IR TRANSMISSION SPECTROSCOPY; LOW CONCENTRATIONS; LOW COSTS; MEASUREMENT SYSTEM; NON-DISPERSIVE INFRARED; NONRESONANT; OPERATING MODES; PHOTOACOUSTIC ABSORPTION; ROT FILTER; SPECIFIC ABSORPTION; SPECIFIC DETECTION; VERSATILE SYSTEM;

EID: 84864276199     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/I2MTC.2012.6229377     Document Type: Conference Paper
Times cited : (9)

References (8)
  • 1
    • 0033034650 scopus 로고    scopus 로고
    • The 13C urea breath test in the diagnosis of Helicobacter pylori infection
    • V. Savarino, S. Vigneri, G. Celle, "The 13C urea breath test in the diagnosis of Helicobacter pylori infection", in GUT, 45 (Suppl I): I18-I22, 1999.
    • (1999) GUT , vol.45 , Issue.SUPPL. I
    • Savarino, V.1    Vigneri, S.2    Celle, G.3
  • 2
    • 84856845935 scopus 로고    scopus 로고
    • Versatile gas measurement system based on combined NDIR transmission and photoacoustic spectroscopy
    • Limerick, Irland, 28. - 31. Oct.
    • E. Pignanelli, K. Kühn, A. Schütze, "Versatile Gas Measurement System Based on Combined NDIR Transmission and Photoacoustic Spectroscopy", in Proc. IEEE Sensors 2011, Limerick, Irland, 28. - 31. Oct., pp. 813 - 816, 2011.
    • (2011) Proc. IEEE Sensors 2011 , pp. 813-816
    • Pignanelli, E.1    Kühn, K.2    Schütze, A.3
  • 3
    • 84873356854 scopus 로고    scopus 로고
    • Kombinierte NDIR-PASGasmessung mit großem Dynamikbereich und inhärenter Selbstüberwachung
    • Dresden, Deutschland, 5. - 7. Dez., ISBN 978-3-942710-53-4
    • K. Kühn, E. Pignanelli, A. Schütze, "Kombinierte NDIR-PASGasmessung mit großem Dynamikbereich und inhärenter Selbstüberwachung," 10. Dresdner Sensor Symposium, Dresden, Deutschland, 5. - 7. Dez., ISBN 978-3-942710-53-4, S. 51-54, 2011.
    • (2011) Dresdner Sensor Symposium , vol.10 , pp. 51-54
    • Kühn, K.1    Pignanelli, E.2    Schütze, A.3
  • 4
    • 80455131049 scopus 로고    scopus 로고
    • Tunable infrared detector with integrated micromachined Fabry-Perot filter
    • Apr 30. doi: 10.1117/1.2909206
    • N. Neumann, M. Ebermann, K. Hiller, S. Kurth, "Tunable infrared detector with integrated micromachined Fabry-Perot filter", J. Micro/Nanolith. MEMS MOEMS 7, 021004 (Apr 30, 2008), doi: 10.1117/1.2909206.
    • (2008) J. Micro/Nanolith. MEMS MOEMS , vol.7 , pp. 021004
    • Neumann, N.1    Ebermann, M.2    Hiller, K.3    Kurth, S.4
  • 5
    • 0035305186 scopus 로고    scopus 로고
    • Application of acoustic resonators in photoacoustic trace gas analysis and metrology
    • A. Miklós, P. Hess, Z. Bozóki, "Application of acoustic resonators in photoacoustic trace gas analysis and metrology", Rev. Sci. Instrum. 72, 1937 (2001).
    • (2001) Rev. Sci. Instrum. , vol.72 , pp. 1937
    • Miklós, A.1    Hess, P.2    Bozóki, Z.3
  • 8
    • 10044268442 scopus 로고    scopus 로고
    • Identification of organic solvents by a virtual multisensor system with hierarchical classification
    • A. Schütze, A. Gramm, T.Rühl, "Identification of organic solvents by a virtual multisensor system with hierarchical classification", IEEE Sensor Journal, vol. 4, no. 6, pp. 857-863, 2004.
    • (2004) IEEE Sensor Journal , vol.4 , Issue.6 , pp. 857-863
    • Schütze, A.1    Gramm, A.2    Rühl, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.