메뉴 건너뛰기




Volumn , Issue , 2012, Pages 203-207

Reproducibility analysis of a TDR-based monitoring system for intravenous drip infusions: Validation of a novel method for flow-rate measurement in IV infusion

Author keywords

biomedical monitoring; medical services; microwave measurements; repeatability and reproducibility; time domain reflectometry

Indexed keywords

BIOMEDICAL MONITORING; EXPERIMENTAL PROCEDURE; LIQUID LEVEL; MEDICAL SERVICES; MONITORING SYSTEM; REAL TIME MONITORING; REPRODUCIBILITIES; TIME DOMAIN REFLECTOMETRY;

EID: 84864260144     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MeMeA.2012.6226673     Document Type: Conference Paper
Times cited : (18)

References (15)
  • 6
    • 0032155126 scopus 로고    scopus 로고
    • A Safe, Accurate Intravenous Infusion Control System
    • E. Barros, M.V.D. dos Santos, "A Safe, Accurate Intravenous Infusion Control System", IEEE Micro, Vol. 18, No.5, 1998, pp. 12-21.
    • (1998) IEEE Micro , vol.18 , Issue.5 , pp. 12-21
    • Barros, E.1    Dos Santos, M.V.D.2
  • 7
    • 77952835453 scopus 로고    scopus 로고
    • A High-Precision Gravity Intravenous Infusion Rate Meter Using CMUT Arrays
    • M. Wang, J. Chen, "A High-Precision Gravity Intravenous Infusion Rate Meter Using CMUT Arrays," Proc. IEEE International Ultrasonics Symposium 2009, .pp. 1355-1358, 2009.
    • (2009) Proc. IEEE International Ultrasonics Symposium 2009 , pp. 1355-1358
    • Wang, M.1    Chen, J.2
  • 8
    • 0035708619 scopus 로고    scopus 로고
    • Time Domain Reflectometry Liquid Level Sensors
    • C. P. Nemarich, "Time Domain Reflectometry Liquid Level Sensors", IEEE Instrumentation and Measurement Magazine, Vol. 4 , No. 4 , 2001, pp.40-44.
    • (2001) IEEE Instrumentation and Measurement Magazine , vol.4 , Issue.4 , pp. 40-44
    • Nemarich, C.P.1
  • 10
    • 79953041466 scopus 로고    scopus 로고
    • Broadband Reflectometry for Diagnostics and Monitoring Applications
    • A. Cataldo and E. De Benedetto, "Broadband Reflectometry for Diagnostics and Monitoring Applications", IEEE- Sensors Journal, Vol. 11, No. 2, 2011, pp. 451 - 459.
    • (2011) IEEE- Sensors Journal , vol.11 , Issue.2 , pp. 451-459
    • Cataldo, A.1    De Benedetto, E.2
  • 11
    • 63749109799 scopus 로고    scopus 로고
    • Enhanced Reflectometry Measurements of Permittivities and Levels in Layered Petrochemical Liquids Using an in-Situ" Coaxial Probe"
    • E. Piuzzi, A. Cataldo, L. Catarinucci, "Enhanced Reflectometry Measurements of Permittivities and Levels in Layered Petrochemical Liquids Using an "In-Situ" Coaxial Probe", Measurement, Vol. 42, No. 5, 2009, pp. 685-696.
    • (2009) Measurement , vol.42 , Issue.5 , pp. 685-696
    • Piuzzi, E.1    Cataldo, A.2    Catarinucci, L.3
  • 14
    • 0015648985 scopus 로고
    • Forming the Fast Fourier Transform of a Step Response in Time-Domain Metrology
    • A.M. Nicolson, "Forming the Fast Fourier Transform of a Step Response in Time-Domain Metrology", Electronics Letters, Vol. 9, No. 14, pp.317-318, 1973.
    • (1973) Electronics Letters , vol.9 , Issue.14 , pp. 317-318
    • Nicolson, A.M.1
  • 15
    • 79955123782 scopus 로고    scopus 로고
    • Logan, UT: Campbell Scientific
    • TDR100 instruction manual - revision 2/10. Logan, UT: Campbell Scientific; 2010. http://www.campbellsci.com/documents/manuals/tdr100.pdf.
    • (2010) TDR100 Instruction Manual - Revision 2/10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.