메뉴 건너뛰기




Volumn 23, Issue 8, 2012, Pages 1089-1093

Endoluminal dilation technique to remove "stuck" tunneled hemodialysis catheters

Author keywords

[No Author keywords available]

Indexed keywords

CEFAZOLIN; FENTANYL; HEMOSTATIC AGENT; MIDAZOLAM;

EID: 84864230769     PISSN: 10510443     EISSN: 15357732     Source Type: Journal    
DOI: 10.1016/j.jvir.2012.04.013     Document Type: Article
Times cited : (29)

References (16)
  • 2
    • 0038315519 scopus 로고    scopus 로고
    • Using cuffed and tunnelled central venous catheters as permanent vascular access for hemodialysis: A prospective study
    • DOI 10.1081/JDI-120021155
    • R. Cetinkaya, A.R. Odabas, Y. Unlu, Y. Selcuk, A. Ates, M. Ceviz Using cuffed and tunnelled central venous catheters as permanent vascular access for hemodialysis: a prospective study Ren Fail 25 2003 431 438 (Pubitemid 36666463)
    • (2003) Renal Failure , vol.25 , Issue.3 , pp. 431-438
    • Cetinkaya, R.1    Odabas, A.R.2    Unlu, Y.3    Selcuk, Y.4    Ates, A.5    Ceviz, M.6
  • 3
    • 0141705179 scopus 로고    scopus 로고
    • Histologic changes in the human vein wall adjacent to indwelling central venous catheters
    • A.R. Forauer, C. Theoharis Histologic changes in the human vein wall adjacent to indwelling central venous catheters J Vasc Interv Radiol 14 2003 1163 1168 (Pubitemid 37193730)
    • (2003) Journal of Vascular and Interventional Radiology , vol.14 , Issue.9 , pp. 1163-1168
    • Forauer, A.R.1    Theoharis, C.2
  • 4
    • 23944478637 scopus 로고    scopus 로고
    • Tethered hemodialysis catheter with retained portions in central vein and right atrium on attempted removal
    • H. Thein, S.K. Ratanjee Tethered hemodialysis catheter with retained portions in central vein and right atrium on attempted removal Am J Kidney Dis 46 2005 e35 e39
    • (2005) Am J Kidney Dis , vol.46
    • Thein, H.1    Ratanjee, S.K.2
  • 6
    • 0037312595 scopus 로고    scopus 로고
    • Adherence of tunnelled haemodialysis catheter to superior vena caval stent: Successful percutaneous removal
    • DOI 10.1093/ndt/18.2.432
    • C.W. McIntyre, M.W. Taal, R.J. Fluck, D. Hinwood Adherence of tunnelled haemodialysis catheter to superior vena caval stent: successful percutaneous removal Nephrol Dial Transplant 18 2003 432 433 (Pubitemid 36181700)
    • (2003) Nephrology Dialysis Transplantation , vol.18 , Issue.2 , pp. 432-433
    • McIntyre, C.W.1    Taal, M.W.2    Fluck, R.J.3    Hinwood, D.4
  • 7
    • 77951618628 scopus 로고    scopus 로고
    • An easy technique for removal of a hemodialysis catheter stuck in central veins
    • J.H. Hong An easy technique for removal of a hemodialysis catheter stuck in central veins J Vasc Access 11 2010 59 62
    • (2010) J Vasc Access , vol.11 , pp. 59-62
    • Hong, J.H.1
  • 8
    • 71549158252 scopus 로고    scopus 로고
    • A novel technique for tethered dialysis catheter removal using the laser sheath
    • R.G. Carrillo, J.D. Garisto, L. Salman, D. Merrill, A. Asif A novel technique for tethered dialysis catheter removal using the laser sheath Semin Dial 22 2009 688 691
    • (2009) Semin Dial , vol.22 , pp. 688-691
    • Carrillo, R.G.1    Garisto, J.D.2    Salman, L.3    Merrill, D.4    Asif, A.5
  • 11
    • 63049121872 scopus 로고    scopus 로고
    • Median sternotomy for an unexpected complication of permanent hemodialysis catheters: "Stuck catheter"
    • S. Akgun, K. Ak, S. Tugrular, A. Civelek, C. Isbir, S. Arsan Median sternotomy for an unexpected complication of permanent hemodialysis catheters: "stuck catheter" Vasa 37 2008 293 296
    • (2008) Vasa , vol.37 , pp. 293-296
    • Akgun, S.1    Ak, K.2    Tugrular, S.3    Civelek, A.4    Isbir, C.5    Arsan, S.6
  • 12
    • 83455164571 scopus 로고    scopus 로고
    • A breakthrough technique for the removal of a hemodialysis catheter stuck in the central vein: Endoluminal balloon dilatation of the stuck catheter
    • J.H. Hong A breakthrough technique for the removal of a hemodialysis catheter stuck in the central vein: endoluminal balloon dilatation of the stuck catheter J Vasc Access 12 2011 381 384
    • (2011) J Vasc Access , vol.12 , pp. 381-384
    • Hong, J.H.1
  • 15
    • 70349250533 scopus 로고    scopus 로고
    • "Permanent" catheters AREN'T
    • D. Watson "Permanent" catheters AREN'T CANNT J 19 2009 39 40
    • (2009) CANNT J , vol.19 , pp. 39-40
    • Watson, D.1
  • 16
    • 84864205062 scopus 로고    scopus 로고
    • Patterns of hemodialysis catheter dysfunction defined according to National Kidney Foundation guidelines as blood flow <300 mL/min
    • doi: 104061/Int J Nephrol.2011/891259
    • R.I. Griffiths, B.B. Newsome, G.A. Block, R.J. Herbert, M.D. Danese Patterns of hemodialysis catheter dysfunction defined according to National Kidney Foundation guidelines as blood flow <300 mL/min Int J Nephrol 2011 doi: 104061/Int J Nephrol.2011/891259
    • (2011) Int J Nephrol
    • Griffiths, R.I.1    Newsome, B.B.2    Block, G.A.3    Herbert, R.J.4    Danese, M.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.