Volumn 50, Issue , 2013, Pages 268-279

Revision of reserve requirements following wind power integration in island power systems

Author keywords

Fuel switch; Generation flexibility; Island power systems; Power reserves; Wind power; Wind power curtailment

Indexed keywords

ELECTRICITY GENERATION; ELECTRICITY-CONSUMPTION; GENERATION FLEXIBILITY; GENERATION SYSTEMS; GEOGRAPHICAL SURFACE; INSTALLED CAPACITY; POWER FLUCTUATIONS; POWER RESERVES; PREDICTION ERRORS; RESERVE REQUIREMENTS; THERMAL GENERATION; TRANSMISSION SYSTEMS; WIND POWER CAPACITY; WIND POWER INTEGRATIONS; WIND POWER VARIATIONS;

EID: 84864095421     PISSN: 09601481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.renene.2012.06.048     Document Type: Article
Times cited : (31)

References (29)
  • 1
    • 84867743763 scopus 로고    scopus 로고
    • Available from:, [accessed 24.10.11], European Commission
    • European Commission Energy, renewable energy, 2011 progress reports 2011, Available from:, [accessed 24.10.11]. http://ec.europa.eu/energy/renewables/reports/reports_en.htm%2520.
    • (2011) Energy, renewable energy, 2011 progress reports
  • 4
    • 77952362758 scopus 로고    scopus 로고
    • Well-functioning balancing markets: a prerequisite for wind power integration
    • Vandezande L., Meeus L., Belmans R., Saguan M., Glachant J.-M. Well-functioning balancing markets: a prerequisite for wind power integration. Energy Policy 2010, 38:3146-3154.
    • (2010) Energy Policy , vol.38 , pp. 3146-3154
    • Vandezande, L.1    Meeus, L.2    Belmans, R.3    Saguan, M.4    Glachant, J.-M.5
  • 7
    • 79951518184 scopus 로고    scopus 로고
    • Determining optimal electricity technology mix with high level of wind power penetration
    • De Jonghe C., Delarue E., Belmans R., D'haeseleer W. Determining optimal electricity technology mix with high level of wind power penetration. Applied Energy 2011, 88:2231-2238.
    • (2011) Applied Energy , vol.88 , pp. 2231-2238
    • De Jonghe, C.1    Delarue, E.2    Belmans, R.3    D'haeseleer, W.4
  • 9
    • 20544464214 scopus 로고    scopus 로고
    • Impact of hourly wind power variations on the system operation in the Nordic countries
    • Holttinen H. Impact of hourly wind power variations on the system operation in the Nordic countries. Wind Energy 2005, 8:197-218.
    • (2005) Wind Energy , vol.8 , pp. 197-218
    • Holttinen, H.1
  • 10
    • 48949115380 scopus 로고    scopus 로고
    • Geographic aggregation and wind power output variance in Denmark
    • Ostergaard P. Geographic aggregation and wind power output variance in Denmark. Energy 2008, 33:1453-1460.
    • (2008) Energy , vol.33 , pp. 1453-1460
    • Ostergaard, P.1
  • 11
    • 28844464366 scopus 로고    scopus 로고
    • Power limitations and energy yield evaluation for wind farms operating in island systems
    • Papathanassiou S., Boulaxis N. Power limitations and energy yield evaluation for wind farms operating in island systems. Renewable Energy 2006, 31:457-479.
    • (2006) Renewable Energy , vol.31 , pp. 457-479
    • Papathanassiou, S.1    Boulaxis, N.2
  • 12
    • 2642578155 scopus 로고    scopus 로고
    • Income loss due to wind energy rejected by the Crete island electrical network - The present situation
    • Kaldellis J., Kavadias K., Filios A., Garofallakis S. Income loss due to wind energy rejected by the Crete island electrical network - The present situation. Applied Energy 2004, 79:127-144.
    • (2004) Applied Energy , vol.79 , pp. 127-144
    • Kaldellis, J.1    Kavadias, K.2    Filios, A.3    Garofallakis, S.4
  • 13
    • 67650082529 scopus 로고    scopus 로고
    • Using standard deviation as a measure of increased operational reserve requirement for wind power
    • Holttinen H., Milligan M., Kirby B., Acker T., Neimane V., Molinski T. Using standard deviation as a measure of increased operational reserve requirement for wind power. Wind Engineering 2008, 32:355-377.
    • (2008) Wind Engineering , vol.32 , pp. 355-377
    • Holttinen, H.1    Milligan, M.2    Kirby, B.3    Acker, T.4    Neimane, V.5    Molinski, T.6
  • 14
    • 67349249985 scopus 로고    scopus 로고
    • Economic valuation of reserves in power systems with high penetration of wind power
    • Morales J., Conejo A., Pérez-ruiz J. Economic valuation of reserves in power systems with high penetration of wind power. Power 2009, 24:900-910.
    • (2009) Power , vol.24 , pp. 900-910
    • Morales, J.1    Conejo, A.2    Pérez-ruiz, J.3
  • 15
    • 42749094870 scopus 로고    scopus 로고
    • Considerations on the backup of wind power: operational backup
    • Luickx P., Delarue E., D'haeseleer W. Considerations on the backup of wind power: operational backup. Applied Energy 2008, 85:787-799.
    • (2008) Applied Energy , vol.85 , pp. 787-799
    • Luickx, P.1    Delarue, E.2    D'haeseleer, W.3
  • 17
    • 84867740537 scopus 로고    scopus 로고
    • Ministry of Commerce Industry and Tourism
    • Available from:, [accessed 10.04.12]
    • Ministry of Commerce Industry and Tourism National renewable energy action plan of Cyprus 2011, Available from:, [accessed 10.04.12]. http://ec.europa.eu/energy/renewables/transparency_platform/action_plan_en.htm.
    • (2011) National renewable energy action plan of Cyprus
  • 18
    • 2542598480 scopus 로고    scopus 로고
    • Unit commitment-a bibliographical survey
    • Padhy N. Unit commitment-a bibliographical survey. IEEE Transactions on Power Systems 2004, 19:1196-1205.
    • (2004) IEEE Transactions on Power Systems , vol.19 , pp. 1196-1205
    • Padhy, N.1
  • 19
    • 67349198069 scopus 로고    scopus 로고
    • Evaluating the impacts of real-time pricing on the usage of wind generation
    • Sioshansi R., Short W. Evaluating the impacts of real-time pricing on the usage of wind generation. IEEE Transactions on Power Systems 2009, 24:516-524.
    • (2009) IEEE Transactions on Power Systems , vol.24 , pp. 516-524
    • Sioshansi, R.1    Short, W.2
  • 22
    • 51649094501 scopus 로고    scopus 로고
    • Pros and cons of exposing renewables to electricity market risks-a comparison of the market integration approaches in Germany, Spain, and the UK
    • Klessmann C., Nabe C., Burges K. Pros and cons of exposing renewables to electricity market risks-a comparison of the market integration approaches in Germany, Spain, and the UK. Energy Policy 2008, 36:3646-3661.
    • (2008) Energy Policy , vol.36 , pp. 3646-3661
    • Klessmann, C.1    Nabe, C.2    Burges, K.3
  • 24
    • 84867745436 scopus 로고    scopus 로고
    • Garrad Hassan and Partners Ltd
    • Available from:, [accessed 10.04.12]
    • Mc Lean J.R., Garrad Hassan and Partners Ltd TradeWind WP2.6 - equivalent wind power curves 2008, Available from:, [accessed 10.04.12]. http://www.trade-wind.eu/.
    • (2008) TradeWind WP2.6 - equivalent wind power curves
    • Mc Lean, J.R.1
  • 25
    • 84867745437 scopus 로고    scopus 로고
    • EREC European Renewable Energy Council
    • Available from:, [accessed 10.04.12]
    • EREC European Renewable Energy Council Mapping renewable energy pathways towards 2020 2011, Available from:, [accessed 10.04.12]. http://www.erec.org.
    • (2011) Mapping renewable energy pathways towards 2020
  • 28
    • 79955900558 scopus 로고    scopus 로고
    • How to deal with negative power price spikes?-flexible voluntary curtailment agreements for large-scale integration of wind
    • Brandstätt C., Brunekreeft G., Jahnke K. How to deal with negative power price spikes?-flexible voluntary curtailment agreements for large-scale integration of wind. Energy Policy 2011, 39:3732-3740.
    • (2011) Energy Policy , vol.39 , pp. 3732-3740
    • Brandstätt, C.1    Brunekreeft, G.2    Jahnke, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.