Volumn 43, Issue 1, 2012, Pages 1185-1192

Wavelet-based de-noising of on-line PD signals captured by Pearson coil in covered-conductor overhead distribution networks

Author keywords

Covered conductor; Electromagnetic disturbances; Partial discharge; Pearson coil; Smart grids; Wavelet transform

Indexed keywords

CONTINUOUS MONITORING; COVERED-CONDUCTOR; DE-NOISING; DIAGNOSTIC TOOLS; ELECTROMAGNETIC DISTURBANCES; EXTERNAL INTERFERENCE; FARADAY CAGE; HIGH FREQUENCY; HIGH VOLTAGE; HIGH-VOLTAGE EQUIPMENTS; INSULATION DIAGNOSIS; ON-SITE MEASUREMENT; OVERHEAD DISTRIBUTION LINE; PARTIAL DISCHARGE DETECTION; PD MEASUREMENTS; PEARSON COIL; PREDICTIVE MAINTENANCE; REMOVE NOISE; SMART GRID;

EID: 84864071543     PISSN: 01420615     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijepes.2012.06.035     Document Type: Article
Times cited : (25)

References (33)
  • 5
    • 51349089122 scopus 로고    scopus 로고
    • On-line PD detection for condition monitoring of covered-conductor overhead distribution networks - A literature survey
    • University of Engineering and Technology (UET), Lahore, Pakistan; March 25-26
    • Hashmi M, Lehtonen M. On-line PD detection for condition monitoring of covered-conductor overhead distribution networks - a literature survey. In: IEEE international conference on electrical engineering (ICEE08), University of Engineering and Technology (UET), Lahore, Pakistan; March 25-26, 2008.
    • (2008) IEEE International Conference on Electrical Engineering (ICEE08)
    • Hashmi, M.1    Lehtonen, M.2
  • 6
    • 77249170172 scopus 로고    scopus 로고
    • Application of wavelet transform to de-noise partial discharge signals in covered-conductor distribution networks
    • Kaunas, Lithuania; September 27-29
    • Hashmi M, Lehtonen M, Nordman M. Application of wavelet transform to de-noise partial discharge signals in covered-conductor distribution networks. In: XVI-th international conference on electromagnetic disturbances (EMD06), Kaunas, Lithuania; September 27-29, 2006.
    • (2006) XVI-th International Conference on Electromagnetic Disturbances (EMD06)
    • Hashmi, M.1    Lehtonen, M.2    Nordman, M.3
  • 8
    • 22744458250 scopus 로고    scopus 로고
    • An improved methodology for application of wavelet transform to partial discharge measurement de-nosing
    • X. Zhou, C. Zhou, and I.J. Kemp An improved methodology for application of wavelet transform to partial discharge measurement de-nosing IEEE Trans Dielectr Electr Insul 12 3 2005 586 594
    • (2005) IEEE Trans Dielectr Electr Insul , vol.12 , Issue.3 , pp. 586-594
    • Zhou, X.1    Zhou, C.2    Kemp, I.J.3
  • 10
    • 0037732564 scopus 로고    scopus 로고
    • Wavelet-based de-noising of partial discharge signals buried in excessive noise and interference
    • L. Satish, and B. Nazneen Wavelet-based de-noising of partial discharge signals buried in excessive noise and interference IEEE Trans Dielectr Electr Insul 10 2 2003 354 367
    • (2003) IEEE Trans Dielectr Electr Insul , vol.10 , Issue.2 , pp. 354-367
    • Satish, L.1    Nazneen, B.2
  • 11
    • 0036613463 scopus 로고    scopus 로고
    • Interpretation of wavelet analysis and its application in partial discharge detection
    • X. Ma, C. Zhou, and I.J. Kemp Interpretation of wavelet analysis and its application in partial discharge detection IEEE Trans Dielectr Electr Insul 9 3 2002 446 457
    • (2002) IEEE Trans Dielectr Electr Insul , vol.9 , Issue.3 , pp. 446-457
    • Ma, X.1    Zhou, C.2    Kemp, I.J.3
  • 15
    • 0033860392 scopus 로고    scopus 로고
    • A literature survey of wavelets in power engineering applications
    • C.H. Lee, Y.J. Wang, and W.L. Huang A literature survey of wavelets in power engineering applications Proc Natl Sci Counc ROC (A) 24 4 2000 249 258
    • (2000) Proc Natl Sci Counc ROC (A) , vol.24 , Issue.4 , pp. 249-258
    • Lee, C.H.1    Wang, Y.J.2    Huang, W.L.3
  • 16
  • 17
    • 84862640306 scopus 로고    scopus 로고
    • Effects of rogowski coil and covered-conductor parameters on the performance of PD measurements in overhead distribution networks
    • M. Hashmi, and M. Lehtonen Effects of rogowski coil and covered-conductor parameters on the performance of PD measurements in overhead distribution networks Int J Innov Energy Sys Power 4 2 2009
    • (2009) Int J Innov Energy Sys Power , vol.4 , Issue.2
    • Hashmi, M.1    Lehtonen, M.2
  • 18
    • 77249149987 scopus 로고    scopus 로고
    • Modeling and experimental verification of on-line PD detection in MV covered-conductor overhead networks
    • M. Hashmi, M. Lehtonen, and M. Nordman Modeling and experimental verification of on-line PD detection in MV covered-conductor overhead networks IEEE Trans Dielectr Electr Insul 17 1 2010 167 180
    • (2010) IEEE Trans Dielectr Electr Insul , vol.17 , Issue.1 , pp. 167-180
    • Hashmi, M.1    Lehtonen, M.2    Nordman, M.3
  • 19
    • 17844367864 scopus 로고    scopus 로고
    • Electromagnetic interference coupling between power cables and sensitive circuits
    • D. Charnock Electromagnetic interference coupling between power cables and sensitive circuits IEEE Trans Power Deliv 20 2 2005 668 673
    • (2005) IEEE Trans Power Deliv , vol.20 , Issue.2 , pp. 668-673
    • Charnock, D.1
  • 21
    • 0030190785 scopus 로고    scopus 로고
    • The use of partial discharge measurements to asses the condition of rotating machine insulation
    • G.C. Stone The use of partial discharge measurements to asses the condition of rotating machine insulation IEEE Electr Insul Mag 12 4 1996
    • (1996) IEEE Electr Insul Mag , vol.12 , Issue.4
    • Stone, G.C.1
  • 23
    • 33747499490 scopus 로고    scopus 로고
    • Practical experiences of on-line partial discharge measurements on a variety of medium-voltage electrical equipment
    • G. Kane, B. Lease, and A. Golubev Practical experiences of on-line partial discharge measurements on a variety of medium-voltage electrical equipment IEEE Trans Indus Appl 35 6 1999
    • (1999) IEEE Trans Indus Appl , vol.35 , Issue.6
    • Kane, G.1    Lease, B.2    Golubev, A.3
  • 28
    • 0029483605 scopus 로고
    • Rejection of narrow-band noise and repetitive pulses in on-site PD measurement
    • U. Kopf, and K. Feser Rejection of narrow-band noise and repetitive pulses in on-site PD measurement IEEE Trans Dielectr Electr Insul 2 1995 1166 1179
    • (1995) IEEE Trans Dielectr Electr Insul , vol.2 , pp. 1166-1179
    • Kopf, U.1    Feser, K.2
  • 31
    • 0036505569 scopus 로고    scopus 로고
    • Automated wavelet selection and thresholding for PD detection
    • X. Ma, C. Zhou, and I.J. Kemp Automated wavelet selection and thresholding for PD detection IEEE Electr Insul Mag 18 2 2002 37 45
    • (2002) IEEE Electr Insul Mag , vol.18 , Issue.2 , pp. 37-45
    • Ma, X.1    Zhou, C.2    Kemp, I.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.