메뉴 건너뛰기




Volumn , Issue , 2005, Pages 1497-1504

Active bidirectional coupling in a cochlear chip

Author keywords

[No Author keywords available]

Indexed keywords

ANALOG VERY LARGE SCALE INTEGRATION; BIDIRECTIONAL COUPLING; COCHLEAR AMPLIFIERS; COCHLEAR MODEL; ELECTROMOTILITY; ORGAN OF CORTI; OUTER HAIR CELL;

EID: 84864058358     PISSN: 10495258     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (8)

References (13)
  • 7
    • 0030988483 scopus 로고    scopus 로고
    • The location of the cochlear amplifier: Spatial representation of a single tone on the guinea pig basilar membrane
    • Russell, I.J. &Nilsen, K.E. (1997) The location of the cochlear amplifier: Spatial representation of a single tone on the guinea pig basilar membrane. Proc. Natl. Acad. Sci. USA, 94: 2660-2664.
    • (1997) Proc. Natl. Acad. Sci. USA , vol.94 , pp. 2660-2664
    • Russell, I.J.1    Nilsen, K.E.2
  • 9
    • 0029119422 scopus 로고
    • A cochlear model using feed-forward outer-hair-cell forces
    • Geisler, C.D. & Sang, C. (1995) A cochlear model using feed-forward outer-hair-cell forces. Hearing Research, 86: 132-146.
    • (1995) Hearing Research , vol.86 , pp. 132-146
    • Geisler, C.D.1    Sang, C.2
  • 10
    • 0001073983 scopus 로고
    • A contrast sensitive silicon retina with reciprocal synapses
    • Moody, J.E. and Lippmann, R.P. (eds.), Morgan Kaufmann, San Mateo, CA
    • Boahen, K.A. & Andreou, A.G. (1992) A contrast sensitive silicon retina with reciprocal synapses. In Moody, J.E. and Lippmann, R.P. (eds.), Advances in Neural Information Processing Systems 4 (NIPS 1992) , pp. 764-772, Morgan Kaufmann, San Mateo, CA.
    • (1992) Advances in Neural Information Processing Systems 4 (NIPS 1992) , pp. 764-772
    • Boahen, K.A.1    Andreou, A.G.2
  • 11
    • 0027841342 scopus 로고
    • Log-domain filtering: An approach to current-mode filtering
    • Frey, D.R. (1993) Log-domain filtering: an approach to current-mode filtering. IEE Proc. G, Circuits Devices Syst., 140 (6): 406-416.
    • (1993) IEE Proc. G, Circuits Devices Syst. , vol.140 , Issue.6 , pp. 406-416
    • Frey, D.R.1
  • 13
    • 0030899626 scopus 로고    scopus 로고
    • Basilar membrane responses to tones at the base of the chinchilla cochlea
    • Ruggero, M.A., Rich, N.C., Narayan, S.S., & Robles, L. (1997) Basilar membrane responses to tones at the base of the chinchilla cochlea. J. Acoust. Soc. Am., 101 (4): 2151-2163.
    • (1997) J. Acoust. Soc. Am. , vol.101 , Issue.4 , pp. 2151-2163
    • Ruggero, M.A.1    Rich, N.C.2    Narayan, S.S.3    Robles, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.