메뉴 건너뛰기




Volumn 144, Issue 2, 2012, Pages 453-458

In vitro assessment of prosthesis type and pressure recovery characteristics: Doppler echocardiography overestimation of bileaflet mechanical and bioprosthetic aortic valve gradients

Author keywords

[No Author keywords available]

Indexed keywords

AORTA; AORTA FLOW; AORTA VALVE PROSTHESIS; ARTICLE; BLOOD VESSEL DIAMETER; DOPPLER ECHOCARDIOGRAPHY; FLOW RATE; HEMODYNAMICS; IN VITRO STUDY; PRESSURE GRADIENT; PRIORITY JOURNAL; PULSATILE FLOW; AORTA VALVE; BIOPROSTHESIS; HEART VALVE PROSTHESIS; HUMAN; MULTIVARIATE ANALYSIS; PATHOPHYSIOLOGY; PROSTHESIS;

EID: 84863988305     PISSN: 00225223     EISSN: 1097685X     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2011.12.036     Document Type: Article
Times cited : (12)

References (17)
  • 1
    • 0024536693 scopus 로고
    • Pressure recovery distal to a stenosis: Potential cause of gradient "overestimation" by Doppler echocardiography
    • R.A. Levine, A. Jimoh, E.G. Cape, S. McMillan, A.P. Yoganathan, and A.E. Weyman Pressure recovery distal to a stenosis: potential cause of gradient "overestimation" by Doppler echocardiography J Am Coll Cardiol 13 1989 706 715
    • (1989) J Am Coll Cardiol , vol.13 , pp. 706-715
    • Levine, R.A.1    Jimoh, A.2    Cape, E.G.3    McMillan, S.4    Yoganathan, A.P.5    Weyman, A.E.6
  • 2
    • 0027070923 scopus 로고
    • Pressure recovery in aortic stenosis: An in vitro study in a pulsatile flow model
    • W. Voelker, H. Reul, T. Stelzer, A. Schmidt, and K.R. Karsch Pressure recovery in aortic stenosis: an in vitro study in a pulsatile flow model J Am Coll Cardiol 20 1992 1585 1593
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1585-1593
    • Voelker, W.1    Reul, H.2    Stelzer, T.3    Schmidt, A.4    Karsch, K.R.5
  • 3
    • 77649262620 scopus 로고    scopus 로고
    • Echo/Doppler evaluation of hemodynamics after aortic valve replacement: Principles of interrogation and evaluation of high gradients
    • D.S. Bach Echo/Doppler evaluation of hemodynamics after aortic valve replacement: principles of interrogation and evaluation of high gradients J Am Coll Cardiol Img 3 2010 296 304
    • (2010) J Am Coll Cardiol Img , vol.3 , pp. 296-304
    • Bach, D.S.1
  • 4
    • 0025552864 scopus 로고
    • Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro: A manifestation of localized gradients and pressure recovery
    • H. Baumgartner, S. Khan, M. DeRobertis, L. Czer, and G. Mauer Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro: a manifestation of localized gradients and pressure recovery Circulation 82 1990 1467 1475
    • (1990) Circulation , vol.82 , pp. 1467-1475
    • Baumgartner, H.1    Khan, S.2    Derobertis, M.3    Czer, L.4    Mauer, G.5
  • 5
    • 0033965062 scopus 로고    scopus 로고
    • Aortic prosthetic valve design and size: Relation to Doppler echocardiographic findings and pressure recovery - And in vitro study
    • O. Bech-Hanssen, K. Caidhal, I. Wallentin, J. Brandberg, B. Wranne, and P. Ask Aortic prosthetic valve design and size: relation to Doppler echocardiographic findings and pressure recovery - and in vitro study J Am Soc Echocardiogr 13 2000 39 50
    • (2000) J Am Soc Echocardiogr , vol.13 , pp. 39-50
    • Bech-Hanssen, O.1    Caidhal, K.2    Wallentin, I.3    Brandberg, J.4    Wranne, B.5    Ask, P.6
  • 6
    • 0035437457 scopus 로고    scopus 로고
    • Assessment of orifice area of prosthetic aortic valves with Doppler echocardiography: An in vivo and in vitro study
    • O. Bech-Hanssen, K. Caidahl, I. Wallentin, P. Ask, and B. Wranne Assessment of orifice area of prosthetic aortic valves with Doppler echocardiography: an in vivo and in vitro study J Thorac Cardiovasc Surg 122 2001 287 295
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 287-295
    • Bech-Hanssen, O.1    Caidahl, K.2    Wallentin, I.3    Ask, P.4    Wranne, B.5
  • 7
    • 0242551295 scopus 로고    scopus 로고
    • Net pressure gradients in aortic prosthetic valves can be estimated by Doppler
    • O. Bech-Hanssen, P. Gjertsson, and E. Houltz Net pressure gradients in aortic prosthetic valves can be estimated by Doppler J Am Soc Echocardiogr 16 2003 858 866
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 858-866
    • Bech-Hanssen, O.1    Gjertsson, P.2    Houltz, E.3
  • 8
    • 55249121454 scopus 로고    scopus 로고
    • Doppler-catheter discrepancies in patients with bileaflet mechanical prostheses or bioprostheses in the aortic valve position
    • O. Aljassim, G. Svensson, E. Houltz, and O. Bech-Hanssen Doppler-catheter discrepancies in patients with bileaflet mechanical prostheses or bioprostheses in the aortic valve position Am J Cardiol 102 2008 1383 1389
    • (2008) Am J Cardiol , vol.102 , pp. 1383-1389
    • Aljassim, O.1    Svensson, G.2    Houltz, E.3    Bech-Hanssen, O.4
  • 9
    • 0037419765 scopus 로고    scopus 로고
    • Discrepancies between catheter and Doppler estimates of valve effective orifice area can be predicted from the pressure recovery phenomenon: Practical implications with regard to quantification of aortic stenosis severity
    • D. Garcia, J.G. Dumesnil, L.G. Durand, L. Kadem, and P. Pibarot Discrepancies between catheter and Doppler estimates of valve effective orifice area can be predicted from the pressure recovery phenomenon: Practical implications with regard to quantification of aortic stenosis severity J Am Coll Cardiol 41 2003 435 442
    • (2003) J Am Coll Cardiol , vol.41 , pp. 435-442
    • Garcia, D.1    Dumesnil, J.G.2    Durand, L.G.3    Kadem, L.4    Pibarot, P.5
  • 11
    • 0029825136 scopus 로고    scopus 로고
    • Importance of pressure recovery for the assessment of aortic stenosis by Doppler ultrasound: Role of aortic size, aortic valve area, and direction of the stenotic jet in vitro
    • J. Niederberger, H. Schima, G. Mauer, and H. Baumgartner Importance of pressure recovery for the assessment of aortic stenosis by Doppler ultrasound: role of aortic size, aortic valve area, and direction of the stenotic jet in vitro Circulation 94 1996 1934 1940
    • (1996) Circulation , vol.94 , pp. 1934-1940
    • Niederberger, J.1    Schima, H.2    Mauer, G.3    Baumgartner, H.4
  • 12
    • 0033133530 scopus 로고    scopus 로고
    • "Over-estimation" of catheter gradients by Doppler ultrasound in patients with aortic stenosis: A predictable manifestation of pressure recovery
    • H. Baumgartner, T. Stefenelli, J. Niederberger, H. Schima, and G. Mauer "Over-estimation" of catheter gradients by Doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery J Am Coll Cardiol 33 1999 1655 1661
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1655-1661
    • Baumgartner, H.1    Stefenelli, T.2    Niederberger, J.3    Schima, H.4    Mauer, G.5
  • 14
    • 0033986302 scopus 로고    scopus 로고
    • Left ventricular apical puncture: A procedure surviving well into the new millennium
    • T. Turgot, M. Deeb, and M. Moscucci Left ventricular apical puncture: a procedure surviving well into the new millennium Cathet Cardiovasc Intervn 49 2000 68 73
    • (2000) Cathet Cardiovasc Intervn , vol.49 , pp. 68-73
    • Turgot, T.1    Deeb, M.2    Moscucci, M.3
  • 15
    • 0032192099 scopus 로고    scopus 로고
    • Inaccurate and misleading valve sizing: A proposed standard for valve size nomenclature
    • G.T. Christakis, K.J. Buth, and B.S. Goldman Inaccurate and misleading valve sizing: a proposed standard for valve size nomenclature Ann Thorac Surg 66 1998 1198 1203
    • (1998) Ann Thorac Surg , vol.66 , pp. 1198-1203
    • Christakis, G.T.1    Buth, K.J.2    Goldman, B.S.3
  • 17
    • 80054966315 scopus 로고    scopus 로고
    • Where is the common sense in aortic valve replacement? A review of hemodynamics and sizing of stented tissue valves
    • T. Doenst, P.A. Amorim, N. Al-Alam, S. Lehmann, C. Mukherjee, and G. Faerber Where is the common sense in aortic valve replacement? A review of hemodynamics and sizing of stented tissue valves J Thorac Cardiovasc Surg 142 2011 1180 1187
    • (2011) J Thorac Cardiovasc Surg , vol.142 , pp. 1180-1187
    • Doenst, T.1    Amorim, P.A.2    Al-Alam, N.3    Lehmann, S.4    Mukherjee, C.5    Faerber, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.