메뉴 건너뛰기




Volumn 3, Issue 2, 2012, Pages 366-379

Parametric imaging of the local attenuation coefficient in human axillary lymph nodes assessed using optical coherence tomography

Author keywords

[No Author keywords available]

Indexed keywords

BODY FLUIDS; ELECTROMAGNETIC WAVE ATTENUATION; TISSUE; TOMOGRAPHY;

EID: 84863903526     PISSN: None     EISSN: 21567085     Source Type: Journal    
DOI: 10.1364/BOE.3.000366     Document Type: Article
Times cited : (76)

References (45)
  • 1
    • 9144226100 scopus 로고    scopus 로고
    • Prognostic and predictive factors in early-stage breast cancer
    • M. Cianfrocca and L. J. Goldstein. "Prognostic and predictive factors in early-stage breast cancer," Oncologist 9(6), 606-616 (2004).
    • (2004) Oncologist , vol.9 , Issue.6 , pp. 606-616
    • Cianfrocca, M.1    Goldstein, L.J.2
  • 3
    • 0035883641 scopus 로고    scopus 로고
    • Lymphedema in a cohort of breast carcinoma survivors 20 years after diagnosis
    • J. A. Petrek, R. T. Senie, M. Peters, and P. P. Rosen. "Lymphedema in a cohort of breast carcinoma survivors 20 years after diagnosis," Cancer 92(6), 1368-1377 (2001).
    • (2001) Cancer , vol.92 , Issue.6 , pp. 1368-1377
    • Petrek, J.A.1    Senie, R.T.2    Peters, M.3    Rosen, P.P.4
  • 6
    • 29844454536 scopus 로고    scopus 로고
    • Lymphatic mapping and sentinel lymph node biopsy in early-stage breast carcinoma
    • T. Kim, A. E. Giuliano, and G. H. Lyman. "Lymphatic mapping and sentinel lymph node biopsy in early-stage breast carcinoma," Cancer 106(1), 4-16 (2006).
    • (2006) Cancer , vol.106 , Issue.1 , pp. 4-16
    • Kim, T.1    Giuliano, A.E.2    Lyman, G.H.3
  • 11
    • 77950835315 scopus 로고    scopus 로고
    • Imaging of human lymph nodes using optical coherence tomography: Potential for staging cancer
    • R. A. McLaughlin, L. Scolaro, P. Robbins, S. Hamza, C. Saunders, and D. D. Sampson. "Imaging of human lymph nodes using optical coherence tomography: potential for staging cancer," Cancer Res. 70(7), 2579-2584 (2010).
    • (2010) Cancer Res , vol.70 , Issue.7 , pp. 2579-2584
    • McLaughlin, R.A.1    Scolaro, L.2    Robbins, P.3    Hamza, S.4    Saunders, C.5    Sampson, D.D.6
  • 13
    • 79952510782 scopus 로고    scopus 로고
    • Three-dimensional optical imaging of microvascular networks within intact lymph node in vivo
    • Y. Jung, Z. Zhi, and R. K. Wang. "Three-dimensional optical imaging of microvascular networks within intact lymph node in vivo," J. Biomed. Opt. 15(5), 050501 (2010).
    • (2010) J. Biomed. Opt , vol.15 , Issue.5 , pp. 050501
    • Jung, Y.1    Zhi, Z.2    Wang, R.K.3
  • 14
    • 0027673680 scopus 로고
    • Measurement of optical properties of biological tissues by low-coherence reflectometry
    • J. M. Schmitt, A. Knüttel, and R. F. Bonner. "Measurement of optical properties of biological tissues by low-coherence reflectometry," Appl. Opt. 32(30), 6032-6042 (1993).
    • (1993) Appl. Opt , vol.32 , Issue.30 , pp. 6032-6042
    • Schmitt, J.M.1    Knüttel, A.2    Bonner, R.F.3
  • 15
    • 6344221496 scopus 로고    scopus 로고
    • Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography
    • D. J. Faber, F. J. van der Meer, M. C. G. Aalders, and T. G. van Leeuwen. "Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography," Opt. Express 12(19), 4353-4365 (2004).
    • (2004) Opt. Express , vol.12 , Issue.19 , pp. 4353-4365
    • Faber, D.J.1    van der Meer, F.J.2    Aalders, M.C.G.3    van Leeuwen, T.G.4
  • 16
    • 77956190919 scopus 로고    scopus 로고
    • Quantitative characterization of developing collagen gels using optical coherence tomography
    • D. Levitz, M. T. Hinds, N. Choudhury, N. T. Tran, S. R. Hanson, and S. L. Jacques. "Quantitative characterization of developing collagen gels using optical coherence tomography," J. Biomed. Opt. 15(2), 026019 (2010).
    • (2010) J. Biomed. Opt , vol.15 , Issue.2 , pp. 026019
    • Levitz, D.1    Hinds, M.T.2    Choudhury, N.3    Tran, N.T.4    Hanson, S.R.5    Jacques, S.L.6
  • 17
    • 33645214926 scopus 로고    scopus 로고
    • Novel algorithm of processing optical coherence tomography images for differentiation of biological tissue pathologies
    • I. V. Turchin, E. A. Sergeeva, L. S. Dolin, V. A. Kamensky, N. M. Shakhova, and R. Richards-Kortum. "Novel algorithm of processing optical coherence tomography images for differentiation of biological tissue pathologies," J. Biomed. Opt. 10(6), 064024 (2005).
    • (2005) J. Biomed. Opt , vol.10 , Issue.6 , pp. 064024
    • Turchin, I.V.1    Sergeeva, E.A.2    Dolin, L.S.3    Kamensky, V.A.4    Shakhova, N.M.5    Richards-Kortum, R.6
  • 18
    • 23844462977 scopus 로고    scopus 로고
    • Localized measurement of optical attenuation coefficients of atherosclerotic plaque constituents by quantitative optical coherence tomography
    • F. J. van der Meer, D. J. Faber, D. M. B. Sassoon, M. C. Aalders, G. Pasterkamp, and T. G. van Leeuwen. "Localized measurement of optical attenuation coefficients of atherosclerotic plaque constituents by quantitative optical coherence tomography," IEEE Trans. Med. Imaging 24(10), 1369-1376 (2005).
    • (2005) IEEE Trans. Med. Imaging , vol.24 , Issue.10 , pp. 1369-1376
    • van der Meer, F.J.1    Faber, D.J.2    Sassoon, D.M.B.3    Aalders, M.C.4    Pasterkamp, G.5    van Leeuwen, T.G.6
  • 19
    • 2442717902 scopus 로고    scopus 로고
    • New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography
    • A. Knüttel, S. Bonev, and W. Knaak. "New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography," J. Biomed. Opt. 9(2), 265-273 (2004).
    • (2004) J. Biomed. Opt , vol.9 , Issue.2 , pp. 265-273
    • Knüttel, A.1    Bonev, S.2    Knaak, W.3
  • 20
    • 0012703814 scopus 로고    scopus 로고
    • Detection of tumorigenesis in urinary bladder with optical coherence tomography: Optical characterization of morphological changes
    • T. Q. Xie, M. L. Zeidel, and Y. T. Pan. "Detection of tumorigenesis in urinary bladder with optical coherence tomography: optical characterization of morphological changes," Opt. Express 10(24), 1431-1443 (2002).
    • (2002) Opt. Express , vol.10 , Issue.24 , pp. 1431-1443
    • Xie, T.Q.1    Zeidel, M.L.2    Pan, Y.T.3
  • 24
    • 0027934282 scopus 로고
    • Optical-coherence tomography of a dense tissue: Statistics of attenuation and backscattering
    • J. M. Schmitt, A. Knüttel, M. Yadlowsky, and M. A. Eckhaus. "Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering," Phys. Med. Biol. 39(10), 1705-1720 (1994).
    • (1994) Phys. Med. Biol , vol.39 , Issue.10 , pp. 1705-1720
    • Schmitt, J.M.1    Knüttel, A.2    Yadlowsky, M.3    Eckhaus, M.A.4
  • 25
    • 51649126449 scopus 로고    scopus 로고
    • Characterization of atherosclerosis plaques by measuring both backscattering and attenuation coefficients in optical coherence tomography
    • C. Y. Xu, J. M. Schmitt, S. G. Carlier, and R. Virmani. "Characterization of atherosclerosis plaques by measuring both backscattering and attenuation coefficients in optical coherence tomography," J. Biomed. Opt. 13(3), 034003 (2008).
    • (2008) J. Biomed. Opt , vol.13 , Issue.3 , pp. 034003
    • Xu, C.Y.1    Schmitt, J.M.2    Carlier, S.G.3    Virmani, R.4
  • 26
    • 70349673919 scopus 로고    scopus 로고
    • Tissue discrimination in anterior eye using three optical parameters obtained by polarization sensitive optical coherence tomography
    • A. Miyazawa, M. Yamanari, S. Makita, M. Miura, K. Kawana, K. Iwaya, H. Goto, and Y. Yasuno. "Tissue discrimination in anterior eye using three optical parameters obtained by polarization sensitive optical coherence tomography," Opt. Express 17(20), 17426-17440 (2009).
    • (2009) Opt. Express , vol.17 , Issue.20 , pp. 17426-17440
    • Miyazawa, A.1    Yamanari, M.2    Makita, S.3    Miura, M.4    Kawana, K.5    Iwaya, K.6    Goto, H.7    Yasuno, Y.8
  • 27
    • 79952180554 scopus 로고    scopus 로고
    • Quantitative measurement of attenuation coefficients of bladder biopsies using optical coherence tomography for grading urothelial carcinoma of the bladder
    • E. C. C. Cauberg, D. M. de Bruin, D. J. Faber, T. M. de Reijke, M. Visser, J. J. M. C. H. de la Rosette, and T. G. van Leeuwen. "Quantitative measurement of attenuation coefficients of bladder biopsies using optical coherence tomography for grading urothelial carcinoma of the bladder," J. Biomed. Opt. 15(6), 066013 (2010).
    • (2010) J. Biomed. Opt , vol.15 , Issue.6 , pp. 066013
    • Cauberg, E.C.C.1    de Bruin, D.M.2    Faber, D.J.3    de Reijke, T.M.4    Visser, M.5    de la Rosette, J.J.M.C.H.6    van Leeuwen, T.G.7
  • 28
    • 0033624456 scopus 로고    scopus 로고
    • Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography
    • A. Knüttel and M. Boehlau-Godau. "Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography," J. Biomed. Opt. 5(1), 83-92 (2000).
    • (2000) J. Biomed. Opt , vol.5 , Issue.1 , pp. 83-92
    • Knüttel, A.1    Boehlau-Godau, M.2
  • 29
    • 0242493238 scopus 로고    scopus 로고
    • Accurate measurement of total attenuation coefficient of thin tissue with optical coherence tomography
    • A. I. Kholodnykh, I. Y. Petrova, M. Motamedi, and R. O. Esenaliev. "Accurate measurement of total attenuation coefficient of thin tissue with optical coherence tomography," IEEE J. Sel. Top. Quantum Electron. 9(2), 210-221 (2003).
    • (2003) IEEE J. Sel. Top. Quantum Electron , vol.9 , Issue.2 , pp. 210-221
    • Kholodnykh, A.I.1    Petrova, I.Y.2    Motamedi, M.3    Esenaliev, R.O.4
  • 31
    • 0034146815 scopus 로고    scopus 로고
    • Analysis of optical coherence tomography systems based on the extended Huygens-Fresnel principle
    • L. Thrane, H. T. Yura, and P. E. Andersen. "Analysis of optical coherence tomography systems based on the extended Huygens-Fresnel principle," J. Opt. Soc. Am. A 17(3), 484-490 (2000).
    • (2000) J. Opt. Soc. Am. A , vol.17 , Issue.3 , pp. 484-490
    • Thrane, L.1    Yura, H.T.2    Andersen, P.E.3
  • 32
    • 0028538082 scopus 로고
    • Optical properties of normal and carcinomatous bronchial tissue
    • J. N. Qu, C. Macaulay, S. Lam, and B. Palcic. "Optical properties of normal and carcinomatous bronchial tissue," Appl. Opt. 33(31), 7397-7405 (1994).
    • (1994) Appl. Opt , vol.33 , Issue.31 , pp. 7397-7405
    • Qu, J.N.1    Macaulay, C.2    Lam, S.3    Palcic, B.4
  • 33
    • 0242661608 scopus 로고    scopus 로고
    • Measurement of the axial point spread function in scattering media using single-mode fiber-based optical coherence tomography
    • T. G. van Leeuwen, D. J. Faber, and M. C. Aalders. "Measurement of the axial point spread function in scattering media using single-mode fiber-based optical coherence tomography," IEEE J. Sel. Top. Quantum Electron. 9(2), 227-233 (2003).
    • (2003) IEEE J. Sel. Top. Quantum Electron , vol.9 , Issue.2 , pp. 227-233
    • van Leeuwen, T.G.1    Faber, D.J.2    Aalders, M.C.3
  • 34
    • 80455137206 scopus 로고    scopus 로고
    • Identification of muscle necrosis in the mdx mouse model of Duchenne muscular dystrophy using three-dimensional optical coherence tomography
    • B. R. Klyen, T. Shavlakadze, H. G. Radley-Crabb, M. D. Grounds, and D. D. Sampson. "Identification of muscle necrosis in the mdx mouse model of Duchenne muscular dystrophy using three-dimensional optical coherence tomography," J. Biomed. Opt. 16(7), 076013 (2011).
    • (2011) J. Biomed. Opt , vol.16 , Issue.7 , pp. 076013
    • Klyen, B.R.1    Shavlakadze, T.2    Radley-Crabb, H.G.3    Grounds, M.D.4    Sampson, D.D.5
  • 35
    • 0346967020 scopus 로고    scopus 로고
    • Determination of complex refractive index of polystyrene microspheres from 370 to 1610 nm
    • X. Y. Ma, J. Q. Lu, R. S. Brock, K. M. Jacobs, P. Yang, and X. H. Hu. "Determination of complex refractive index of polystyrene microspheres from 370 to 1610 nm," Phys. Med. Biol. 48(24), 4165-4172 (2003).
    • (2003) Phys. Med. Biol , vol.48 , Issue.24 , pp. 4165-4172
    • Ma, X.Y.1    Lu, J.Q.2    Brock, R.S.3    Jacobs, K.M.4    Yang, P.5    Hu, X.H.6
  • 36
    • 77950550643 scopus 로고    scopus 로고
    • Added soft tissue contrast using signal attenuation and the fractal dimension for optical coherence tomography images of porcine arterial tissue
    • C. Flueraru, D. P. Popescu, Y. Mao, S. Chang, and M. G. Sowa. "Added soft tissue contrast using signal attenuation and the fractal dimension for optical coherence tomography images of porcine arterial tissue," Phys. Med. Biol. 55(8), 2317-2331 (2010).
    • (2010) Phys. Med. Biol , vol.55 , Issue.8 , pp. 2317-2331
    • Flueraru, C.1    Popescu, D.P.2    Mao, Y.3    Chang, S.4    Sowa, M.G.5
  • 38
    • 77949771243 scopus 로고    scopus 로고
    • Apoptosis- and necrosis-induced changes in light attenuation measured by optical coherence tomography
    • F. J. van der Meer, D. J. Faber, M. C. G. Aalders, A. A. Poot, I. Vermes, and T. G. van Leeuwen. "Apoptosis- and necrosis-induced changes in light attenuation measured by optical coherence tomography," Lasers Med. Sci. 25(2), 259-267 (2010).
    • (2010) Lasers Med. Sci , vol.25 , Issue.2 , pp. 259-267
    • van der Meer, F.J.1    Faber, D.J.2    Aalders, M.C.G.3    Poot, A.A.4    Vermes, I.5    van Leeuwen, T.G.6
  • 39
    • 44849138888 scopus 로고    scopus 로고
    • Automated algorithm for differentiation of human breast tissue using low coherence interferometry for fine needle aspiration biopsy guidance
    • B. D. Goldberg, N. V. Iftimia, J. E. Bressner, M. B. Pitman, E. Halpern, B. E. Bouma, and G. J. Tearney. "Automated algorithm for differentiation of human breast tissue using low coherence interferometry for fine needle aspiration biopsy guidance," J. Biomed. Opt. 13(1), 014014 (2008).
    • (2008) J. Biomed. Opt , vol.13 , Issue.1 , pp. 014014
    • Goldberg, B.D.1    Iftimia, N.V.2    Bressner, J.E.3    Pitman, M.B.4    Halpern, E.5    Bouma, B.E.6    Tearney, G.J.7
  • 40
    • 20644456680 scopus 로고    scopus 로고
    • A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance
    • N. V. Iftimia, B. E. Bouma, M. B. Pitman, B. Goldberg, J. Bressner, and G. J. Tearney. "A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance," Rev. Sci. Instrum. 76(6), 064301 (2005).
    • (2005) Rev. Sci. Instrum , vol.76 , Issue.6 , pp. 064301
    • Iftimia, N.V.1    Bouma, B.E.2    Pitman, M.B.3    Goldberg, B.4    Bressner, J.5    Tearney, G.J.6
  • 41
    • 33845370158 scopus 로고    scopus 로고
    • Computational methods for analysis of human breast tumor tissue in optical coherence tomography images
    • A. M. Zysk and S. A. Boppart. "Computational methods for analysis of human breast tumor tissue in optical coherence tomography images," J. Biomed. Opt. 11(5), 054015 (2006).
    • (2006) J. Biomed. Opt , vol.11 , Issue.5 , pp. 054015
    • Zysk, A.M.1    Boppart, S.A.2
  • 42
    • 70349244924 scopus 로고    scopus 로고
    • Automated algorithm for breast tissue differentiation in optical coherence tomography
    • M. Mujat, R. D. Ferguson, D. X. Hammer, C. Gittins, and N. Iftimia. "Automated algorithm for breast tissue differentiation in optical coherence tomography," J. Biomed. Opt. 14(3), 034040 (2009).
    • (2009) J. Biomed. Opt , vol.14 , Issue.3 , pp. 034040
    • Mujat, M.1    Ferguson, R.D.2    Hammer, D.X.3    Gittins, C.4    Iftimia, N.5
  • 44
    • 23444431971 scopus 로고    scopus 로고
    • The effect of tissue fixation and processing on breast cancer size
    • B. Pritt, J. J. Tessitore, D. L. Weaver, and H. Blaszyk. "The effect of tissue fixation and processing on breast cancer size," Hum. Pathol. 36(7), 756-760 (2005).
    • (2005) Hum. Pathol , vol.36 , Issue.7 , pp. 756-760
    • Pritt, B.1    Tessitore, J.J.2    Weaver, D.L.3    Blaszyk, H.4
  • 45
    • 33645215633 scopus 로고    scopus 로고
    • Effect of tissue preservation on imaging using ultrahigh resolution optical coherence tomography
    • P. L. Hsiung, P. R. Nambiar, and J. G. Fujimoto. "Effect of tissue preservation on imaging using ultrahigh resolution optical coherence tomography," J. Biomed. Opt. 10(6), 064033 (2005).
    • (2005) J. Biomed. Opt , vol.10 , Issue.6 , pp. 064033
    • Hsiung, P.L.1    Nambiar, P.R.2    Fujimoto, J.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.