-
1
-
-
0022997296
-
Functional architecture of cortex revealed by optical imaging of intrinsic signals
-
A. Grinvald, E. Lieke, R. D. Frostig, C. D. Gilbert, and T. N. Wiesel, “Functional architecture of cortex revealed by optical imaging of intrinsic signals,” Nature 324(6095), 361-364 (1986).
-
(1986)
Nature
, vol.324
, Issue.6095
, pp. 361-364
-
-
Grinvald, A.1
Lieke, E.2
Frostig, R.D.3
Gilbert, C.D.4
Wiesel, T.N.5
-
2
-
-
0030843420
-
Non-invasive optical spectroscopy and imaging of human brain function
-
A. Villringer and B. Chance, “Non-invasive optical spectroscopy and imaging of human brain function,” Trends Neurosci. 20(10), 435-442 (1997).
-
(1997)
Trends Neurosci
, vol.20
, Issue.10
, pp. 435-442
-
-
Villringer, A.1
Chance, B.2
-
3
-
-
67651046180
-
Advances in light microscopy for neuroscience
-
B. A. Wilt, L. D. Burns, E. T. Wei Ho, K. K. Ghosh, E. A. Mukamel, and M. J. Schnitzer, “Advances in light microscopy for neuroscience,” Annu. Rev. Neurosci. 32(1), 435-506 (2009).
-
(2009)
Annu. Rev. Neurosci.
, vol.32
, Issue.1
, pp. 435-506
-
-
Wilt, B.A.1
Burns, L.D.2
Wei Ho, E.T.3
Ghosh, K.K.4
Mukamel, E.A.5
Schnitzer, M.J.6
-
4
-
-
0024439730
-
Continuous measurement of cerebral cortical blood flow by laser-Doppler flowmetry in a rat stroke model
-
U. Dirnagl, B. Kaplan, M. Jacewicz, and W. Pulsinelli, “Continuous measurement of cerebral cortical blood flow by laser-Doppler flowmetry in a rat stroke model,” J. Cereb. Blood Flow Metab. 9(5), 589-596 (1989).
-
(1989)
J. Cereb. Blood Flow Metab.
, vol.9
, Issue.5
, pp. 589-596
-
-
Dirnagl, U.1
Kaplan, B.2
Jacewicz, M.3
Pulsinelli, W.4
-
5
-
-
0035092312
-
Dynamic imaging of cerebral blood flow using laser speckle
-
A. K. Dunn, H. Bolay, M. A. Moskowitz, and D. A. Boas, “Dynamic imaging of cerebral blood flow using laser speckle,” J. Cereb. Blood Flow Metab. 21(3), 195-201 (2001).
-
(2001)
J. Cereb. Blood Flow Metab.
, vol.21
, Issue.3
, pp. 195-201
-
-
Dunn, A.K.1
Bolay, H.2
Moskowitz, M.A.3
Boas, D.A.4
-
6
-
-
3142695418
-
Laminar optical tomography: Demonstration of millimeter-scale depth-resolved imaging in turbid media
-
E. M. Hillman, D. A. Boas, A. M. Dale, and A. K. Dunn, “Laminar optical tomography: demonstration of millimeter-scale depth-resolved imaging in turbid media,” Opt. Lett. 29(14), 1650-1652 (2004).
-
(2004)
Opt. Lett.
, vol.29
, Issue.14
, pp. 1650-1652
-
-
Hillman, E.M.1
Boas, D.A.2
Dale, A.M.3
Dunn, A.K.4
-
7
-
-
0025342635
-
Two-photon laser scanning fluorescence microscopy
-
W. Denk, J. H. Strickler, and W. W. Webb, “Two-photon laser scanning fluorescence microscopy,” Science 248(4951), 73-76 (1990).
-
(1990)
Science
, vol.248
, Issue.4951
, pp. 73-76
-
-
Denk, W.1
Strickler, J.H.2
Webb, W.W.3
-
8
-
-
0001226983
-
Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media
-
Z. Chen, T. E. Milner, D. Dave, and J. S. Nelson, “Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media,” Opt. Lett. 22(1), 64-66 (1997).
-
(1997)
Opt. Lett.
, vol.22
, Issue.1
, pp. 64-66
-
-
Chen, Z.1
Milner, T.E.2
Dave, D.3
Nelson, J.S.4
-
9
-
-
0000063298
-
In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography
-
J. A. Izatt, M. D. Kulkarni, S. Yazdanfar, J. K. Barton, and A. J. Welch, “In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography,” Opt. Lett. 22(18), 1439-1441 (1997).
-
(1997)
Opt. Lett
, vol.22
, Issue.18
, pp. 1439-1441
-
-
Izatt, J.A.1
Kulkarni, M.D.2
Yazdanfar, S.3
Barton, J.K.4
Welch, A.J.5
-
10
-
-
0038618462
-
Performance of Fourier domain vs. Time domain optical coherence tomography
-
R. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, “Performance of Fourier domain vs. time domain optical coherence tomography,” Opt. Express 11(8), 889-894 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.8
, pp. 889-894
-
-
Leitgeb, R.1
Hitzenberger, C.K.2
Fercher, A.F.3
-
11
-
-
2942733251
-
In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical coherence tomography, Opt
-
B. R. White, M. C. Pierce, N. Nassif, B. Cense, B. H. Park, G. J. Tearney, B. E. Bouma, T. C. Chen, and J. F. de Boer, “In vivo dynamic human retinal blood flow imaging using ultra-high-speed spectral domain optical coherence tomography,” Opt. Express 11(25), 3490-3497 (2003).
-
(2003)
Express
, vol.11
, Issue.25
, pp. 3490-3497
-
-
White, B.R.1
Pierce, M.C.2
Nassif, N.3
Cense, B.4
Park, B.H.5
Tearney, G.J.6
Bouma, B.E.7
Chen, T.C.8
De Boer, J.F.9
-
12
-
-
70350565505
-
Three-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imaging
-
B. J. Vakoc, R. M. Lanning, J. A. Tyrrell, T. P. Padera, L. A. Bartlett, T. Stylianopoulos, L. L. Munn, G. J. Tearney, D. Fukumura, R. K. Jain, and B. E. Bouma, “Three-dimensional microscopy of the tumor microenvironment in vivo using optical frequency domain imaging,” Nat. Med. 15(10), 1219-1223 (2009).
-
(2009)
Nat. Med.
, vol.15
, Issue.10
, pp. 1219-1223
-
-
Vakoc, B.J.1
Lanning, R.M.2
Tyrrell, J.A.3
Padera, T.P.4
Bartlett, L.A.5
Stylianopoulos, T.6
Munn, L.L.7
Tearney, G.J.8
Fukumura, D.9
Jain, R.K.10
Bouma, B.E.11
-
13
-
-
0026254046
-
Optical coherence tomography
-
D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, and et, “Optical coherence tomography,” Science 254(5035), 1178-1181 (1991).
-
(1991)
Science
, vol.254
, Issue.5035
, pp. 1178-1181
-
-
Huang, D.1
Swanson, E.A.2
Lin, C.P.3
Schuman, J.S.4
Stinson, W.G.5
Chang, W.6
Hee, M.R.7
Flotte, T.8
Gregory, K.9
Puliafito, C.A.10
-
14
-
-
35948962341
-
In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography
-
Y. Wang, B. A. Bower, J. A. Izatt, O. Tan, and D. Huang, “In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomography,” J. Biomed. Opt. 12(4), 041215 (2007).
-
(2007)
J. Biomed. Opt
, vol.12
, Issue.4
, pp. 41215
-
-
Wang, Y.1
Bower, B.A.2
Izatt, J.A.3
Tan, O.4
Huang, D.5
-
15
-
-
76149109125
-
Quantitative cerebral blood flow with optical coherence tomography
-
V. J. Srinivasan, S. Sakadzic, I. Gorczynska, S. Ruvinskaya, W. Wu, J. G. Fujimoto, and D. A. Boas, “Quantitative cerebral blood flow with optical coherence tomography,” Opt. Express 18(3), 2477-2494 (2010).
-
(2010)
Opt. Express
, vol.18
, Issue.3
, pp. 2477-2494
-
-
Srinivasan, V.J.1
Sakadzic, S.2
Gorczynska, I.3
Ruvinskaya, S.4
Wu, W.5
Fujimoto, J.G.6
Boas, D.A.7
-
16
-
-
0032417876
-
Fluctuations and stimulus-induced changes in blood flow observed in individual capillaries in layers 2 through 4 of rat neocortex
-
D. Kleinfeld, P. P. Mitra, F. Helmchen, and W. Denk, “Fluctuations and stimulus-induced changes in blood flow observed in individual capillaries in layers 2 through 4 of rat neocortex,” Proc. Natl. Acad. Sci. U.S.A. 95(26), 15741-15746 (1998).
-
(1998)
Proc. Natl. Acad. Sci. U.S.A.
, vol.95
, Issue.26
, pp. 15741-15746
-
-
Kleinfeld, D.1
Mitra, P.P.2
Helmchen, F.3
Denk, W.4
-
17
-
-
33747769290
-
Optical coherence angiography
-
S. Makita, Y. Hong, M. Yamanari, T. Yatagai, and Y. Yasuno, “Optical coherence angiography,” Opt. Express 14(17), 7821-7840 (2006).
-
(2006)
Opt. Express
, vol.14
, Issue.17
, pp. 7821-7840
-
-
Makita, S.1
Hong, Y.2
Yamanari, M.3
Yatagai, T.4
Yasuno, Y.5
-
18
-
-
34147096380
-
Three dimensional optical angiography
-
R. K. Wang, S. L. Jacques, Z. Ma, S. Hurst, S. R. Hanson, and A. Gruber, “Three dimensional optical angiography,” Opt. Express 15(7), 4083-4097 (2007).
-
(2007)
Opt. Express
, vol.15
, Issue.7
, pp. 4083-4097
-
-
Wang, R.K.1
Jacques, S.L.2
Ma, Z.3
Hurst, S.4
Hanson, S.R.5
Gruber, A.6
-
19
-
-
49149121261
-
Single-pass volumetric bidirectional blood flow imaging spectral domain optical coherence tomography using a modified Hilbert transform
-
Y. K. Tao, A. M. Davis, and J. A. Izatt, “Single-pass volumetric bidirectional blood flow imaging spectral domain optical coherence tomography using a modified Hilbert transform,” Opt. Express 16(16), 12350-12361 (2008).
-
(2008)
Opt. Express
, vol.16
, Issue.16
, pp. 12350-12361
-
-
Tao, Y.K.1
Davis, A.M.2
Izatt, J.A.3
-
20
-
-
47549087530
-
Speckle variance detection of microvasculature using swept-source optical coherence tomography
-
A. Mariampillai, B. A. Standish, E. H. Moriyama, M. Khurana, N. R. Munce, M. K. Leung, J. Jiang, A. Cable, B. C. Wilson, I. A. Vitkin, and V. X. Yang, “Speckle variance detection of microvasculature using swept-source optical coherence tomography,” Opt. Lett. 33(13), 1530-1532 (2008).
-
(2008)
Opt. Lett.
, vol.33
, Issue.13
, pp. 1530-1532
-
-
Mariampillai, A.1
Standish, B.A.2
Moriyama, E.H.3
Khurana, M.4
Munce, N.R.5
Leung, M.K.6
Jiang, J.7
Cable, A.8
Wilson, B.C.9
Vitkin, I.A.10
Yang, V.X.11
-
21
-
-
76149140928
-
Rapid volumetric angiography of cortical microvasculature with optical coherence tomography
-
V. J. Srinivasan, J. Y. Jiang, M. A. Yaseen, H. Radhakrishnan, W. Wu, S. Barry, A. E. Cable, and D. A. Boas, “Rapid volumetric angiography of cortical microvasculature with optical coherence tomography,” Opt. Lett. 35(1), 43-45 (2010).
-
(2010)
Opt. Lett.
, vol.35
, Issue.1
, pp. 43-45
-
-
Srinivasan, V.J.1
Jiang, J.Y.2
Yaseen, M.A.3
Radhakrishnan, H.4
Wu, W.5
Barry, S.6
Cable, A.E.7
Boas, D.A.8
-
22
-
-
33646550173
-
Real-time in vivo blood-flow imaging by moving-scatterer-sensitive spectral-domain optical Doppler tomography
-
H. Ren, T. Sun, D. J. MacDonald, M. J. Cobb, and X. Li, “Real-time in vivo blood-flow imaging by moving-scatterer-sensitive spectral-domain optical Doppler tomography,” Opt. Lett. 31(7), 927-929 (2006).
-
(2006)
Opt. Lett.
, vol.31
, Issue.7
, pp. 927-929
-
-
Ren, H.1
Sun, T.2
Macdonald, D.J.3
Cobb, M.J.4
Li, X.5
-
23
-
-
77954929404
-
Optimized speckle variance OCT imaging of microvasculature
-
A. Mariampillai, M. K. Leung, M. Jarvi, B. A. Standish, K. Lee, B. C. Wilson, A. Vitkin, and V. X. Yang, “Optimized speckle variance OCT imaging of microvasculature,” Opt. Lett. 35(8), 1257-1259 (2010).
-
(2010)
Opt. Lett.
, vol.35
, Issue.8
, pp. 1257-1259
-
-
Mariampillai, A.1
Leung, M.K.2
Jarvi, M.3
Standish, B.A.4
Lee, K.5
Wilson, B.C.6
Vitkin, A.7
Yang, V.X.8
-
24
-
-
35148870003
-
Mobility and transverse flow visualization using phase variance contrast with spectral domain optical coherence tomography
-
J. Fingler, D. Schwartz, C. Yang, and S. E. Fraser, “Mobility and transverse flow visualization using phase variance contrast with spectral domain optical coherence tomography,” Opt. Express 15(20), 12636-12653 (2007).
-
(2007)
Opt. Express
, vol.15
, Issue.20
, pp. 12636-12653
-
-
Fingler, J.1
Schwartz, D.2
Yang, C.3
Fraser, S.E.4
-
25
-
-
0037088454
-
Imaging and quantifying transverse flow velocity with the Doppler bandwidth in a phase-resolved functional optical coherence tomography
-
H. Ren, K. M. Brecke, Z. Ding, Y. Zhao, J. S. Nelson, and Z. Chen, “Imaging and quantifying transverse flow velocity with the Doppler bandwidth in a phase-resolved functional optical coherence tomography,” Opt. Lett. 27(6), 409-411 (2002).
-
(2002)
Opt. Lett.
, vol.27
, Issue.6
, pp. 409-411
-
-
Ren, H.1
Brecke, K.M.2
Ding, Z.3
Zhao, Y.4
Nelson, J.S.5
Chen, Z.6
-
26
-
-
0038677558
-
Doppler angle and flow velocity mapping by combined Doppler shift and Doppler bandwidth measurements in optical Doppler tomography
-
D. Piao, L. L. Otis, and Q. Zhu, “Doppler angle and flow velocity mapping by combined Doppler shift and Doppler bandwidth measurements in optical Doppler tomography,” Opt. Lett. 28(13), 1120-1122 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.13
, pp. 1120-1122
-
-
Piao, D.1
Otis, L.L.2
Zhu, Q.3
-
27
-
-
0042810881
-
Determination of flow velocity vector based on Doppler shift and spectrum broadening with optical coherence tomography
-
S. G. Proskurin, Y. He, and R. K. Wang, “Determination of flow velocity vector based on Doppler shift and spectrum broadening with optical coherence tomography,” Opt. Lett. 28(14), 1227-1229 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.14
, pp. 1227-1229
-
-
Proskurin, S.G.1
He, Y.2
Wang, R.K.3
-
28
-
-
78649279905
-
Autocorrelation optical coherence tomography for mapping transverse particle-flow velocity
-
Y. Wang and R. Wang, “Autocorrelation optical coherence tomography for mapping transverse particle-flow velocity,” Opt. Lett. 35(21), 3538-3540 (2010).
-
(2010)
Opt. Lett.
, vol.35
, Issue.21
, pp. 3538-3540
-
-
Wang, Y.1
Wang, R.2
-
29
-
-
78649699421
-
Chronic optical access through a polished and reinforced thinned skull
-
P. J. Drew, A. Y. Shih, J. D. Driscoll, P. M. Knutsen, P. Blinder, D. Davalos, K. Akassoglou, P. S. Tsai, and D. Kleinfeld, “Chronic optical access through a polished and reinforced thinned skull,” Nat. Methods 7(12), 981-984 (2010).
-
(2010)
Nat. Methods
, vol.7
, Issue.12
, pp. 981-984
-
-
Drew, P.J.1
Shih, A.Y.2
Driscoll, J.D.3
Knutsen, P.M.4
Blinder, P.5
Davalos, D.6
Akassoglou, K.7
Tsai, P.S.8
Kleinfeld, D.9
-
30
-
-
79960743246
-
Eigendecomposition-based clutter filtering technique for optical microangiography
-
S. Yousefi, Z. Zhi, and R. Wang, “Eigendecomposition-based clutter filtering technique for optical microangiography,” IEEE Trans. Biomed. Eng. 58(8), 2316-2323 (2011).
-
(2011)
IEEE Trans. Biomed. Eng.
, vol.58
, Issue.8
, pp. 2316-2323
-
-
Yousefi, S.1
Zhi, Z.2
Wang, R.3
-
31
-
-
0032607462
-
Direct velocity sensing of flow distribution based on low-coherence interferometry
-
Y. Imai and K. Tanaka, “Direct velocity sensing of flow distribution based on low-coherence interferometry,” J. Opt. Soc. Am. A 16(8), 2007-2012 (1999).
-
(1999)
J. Opt. Soc. Am. A
, vol.16
, Issue.8
, pp. 2007-2012
-
-
Imai, Y.1
Tanaka, K.2
-
32
-
-
0001142668
-
Flow behavior of erythrocytes. 2. Particle motions in concentrated suspensions of ghost cells
-
H. L. Goldsmith and J. C. Marlow, “Flow behavior of erythrocytes. 2. Particle motions in concentrated suspensions of ghost cells,” J. Colloid Interface Sci. 71(2), 383-407 (1979).
-
(1979)
J. Colloid Interface Sci.
, vol.71
, Issue.2
, pp. 383-407
-
-
Goldsmith, H.L.1
Marlow, J.C.2
-
33
-
-
77956625944
-
Static and dynamic light scattering of healthy and malaria-parasite invaded red blood cells
-
Y. Park, M. Diez-Silva, D. Fu, G. Popescu, W. Choi, I. Barman, S. Suresh, and M. S. Feld, “Static and dynamic light scattering of healthy and malaria-parasite invaded red blood cells,” J. Biomed. Opt. 15(2), 020506 (2010).
-
(2010)
J. Biomed. Opt
, vol.15
, Issue.2
, pp. 20506
-
-
Park, Y.1
Diez-Silva, M.2
Fu, D.3
Popescu, G.4
Choi, W.5
Barman, I.6
Suresh, S.7
Feld, M.S.8
-
34
-
-
78149327175
-
Path-length-resolved diffusive particle dynamics in spectral-domain optical coherence tomography
-
J. Kalkman, R. Sprik, and T. G. van Leeuwen, “Path-length-resolved diffusive particle dynamics in spectral-domain optical coherence tomography,” Phys. Rev. Lett. 105(19), 198-302 (2010).
-
(2010)
Phys. Rev. Lett.
, vol.105
, Issue.19
, pp. 198-302
-
-
Kalkman, J.1
Sprik, R.2
Van Leeuwen, T.G.3
-
35
-
-
33746698933
-
Spatial flow-volume dissociation of the cerebral microcirculatory response to mild hypercapnia
-
E. B. Hutchinson, B. Stefanovic, A. P. Koretsky, and A. C. Silva, “Spatial flow-volume dissociation of the cerebral microcirculatory response to mild hypercapnia,” Neuroimage 32(2), 520-530 (2006).
-
(2006)
Neuroimage
, vol.32
, Issue.2
, pp. 520-530
-
-
Hutchinson, E.B.1
Stefanovic, B.2
Koretsky, A.P.3
Silva, A.C.4
-
36
-
-
34247465685
-
Empirical model functions to calculate hematocrit-dependent optical properties of human blood
-
M. Meinke, G. Müller, J. Helfmann, and M. Friebel, “Empirical model functions to calculate hematocrit-dependent optical properties of human blood,” Appl. Opt. 46(10), 1742-1753 (2007).
-
(2007)
Appl. Opt.
, vol.46
, Issue.10
, pp. 1742-1753
-
-
Meinke, M.1
Müller, G.2
Helfmann, J.3
Friebel, M.4
-
37
-
-
0018126793
-
The red cell as a fluid droplet: Tank tread-like motion of the human erythrocyte membrane in shear flow
-
T. M. Fischer, M. Stöhr-Lissen, and H. Schmid-Schönbein, “The red cell as a fluid droplet: tank tread-like motion of the human erythrocyte membrane in shear flow,” Science 202(4370), 894-896 (1978).
-
(1978)
Science
, vol.202
, Issue.4370
, pp. 894-896
-
-
Fischer, T.M.1
Stöhr-Lissen, M.2
Schmid-Schönbein, H.3
-
38
-
-
16244364050
-
Microvascular rheology and hemodynamics
-
H. H. Lipowsky, “Microvascular rheology and hemodynamics,” Microcirculation 12(1), 5-15 (2005).
-
(2005)
Microcirculation
, vol.12
, Issue.1
, pp. 5-15
-
-
Lipowsky, H.H.1
-
39
-
-
61549107479
-
Ultra-high-speed volumetric tomography of human retinal blood flow
-
T. Schmoll, C. Kolbitsch, and R. A. Leitgeb, “Ultra-high-speed volumetric tomography of human retinal blood flow,” Opt. Express 17(5), 4166-4176 (2009).
-
(2009)
Opt. Express
, vol.17
, Issue.5
, pp. 4166-4176
-
-
Schmoll, T.1
Kolbitsch, C.2
Leitgeb, R.A.3
-
40
-
-
0019583049
-
Model for laser Doppler measurements of blood flow in tissue
-
R. Bonner and R. Nossal, “Model for laser Doppler measurements of blood flow in tissue,” Appl. Opt. 20(12), 2097-2107 (1981).
-
(1981)
Appl. Opt.
, vol.20
, Issue.12
, pp. 2097-2107
-
-
Bonner, R.1
Nossal, R.2
-
41
-
-
72449129943
-
Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique
-
J. Fingler, R. J. Zawadzki, J. S. Werner, D. Schwartz, and S. E. Fraser, “Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique,” Opt. Express 17(24), 22190-22200 (2009).
-
(2009)
Opt. Express
, vol.17
, Issue.24
, pp. 22190-22200
-
-
Fingler, J.1
Zawadzki, R.J.2
Werner, J.S.3
Schwartz, D.4
Fraser, S.E.5
|