메뉴 건너뛰기




Volumn 9, Issue 4, 2012, Pages

Inclusion of temporal priors for automated neonatal EEG classification

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATED DETECTION; DATA SETS; FALSE DETECTIONS; HYPOXIC ISCHEMIC ENCEPHALOPATHIES; NEONATAL EEG; NEONATAL SEIZURE; PROBABILISTIC FRAMEWORK; RECEIVER OPERATING CHARACTERISTICS; SKEW-NORMAL DISTRIBUTION; TEMPORAL EVOLUTION;

EID: 84863838391     PISSN: 17412560     EISSN: 17412552     Source Type: Journal    
DOI: 10.1088/1741-2560/9/4/046002     Document Type: Review
Times cited : (20)

References (31)
  • 2
    • 44049097334 scopus 로고    scopus 로고
    • Defining the gap between electrographic seizure burden, clinical expression and staff recognition of neonatal seizures
    • Murray D, Boylan G, Ali I, Ryan C, Murphy B and Connolly S 2008 Defining the gap between electrographic seizure burden, clinical expression and staff recognition of neonatal seizures Arch. Dis. Child. Fetal. Neonatal. Ed. 93 187-91
    • (2008) Arch. Dis. Child. Fetal. Neonatal. Ed. , vol.93 , pp. 187-191
    • Murray, D.1    Boylan, G.2    Ali, I.3    Ryan, C.4    Murphy, B.5    Connolly, S.6
  • 4
    • 0036114029 scopus 로고    scopus 로고
    • A computer-aided detection of EEG seizures in infants: A singular-spectrum approach and performance comparison
    • DOI 10.1109/10.995684, PII S0018929402039988
    • Celka P and Colditz P 2002 A computer-aided detection of EEG seizures in infants, a singular-spectrum approach and performance comparison IEEE Trans. Biomed. Eng. 49 455-62 (Pubitemid 34411814)
    • (2002) IEEE Transactions on Biomedical Engineering , vol.49 , Issue.5 , pp. 455-462
    • Celka, P.1    Colditz, P.2
  • 7
    • 36549062615 scopus 로고    scopus 로고
    • A multistage knowledge-based system for EEG seizure detection in newborn infants
    • DOI 10.1016/j.clinph.2007.08.012, PII S1388245707004294
    • Aarabi A, Grebe R and Wallois F 2007 A multistage knowledge-based system for EEG seizure detection in newborn infants Clin. Neurophysiol. 118 2781-97 (Pubitemid 350180610)
    • (2007) Clinical Neurophysiology , vol.118 , Issue.12 , pp. 2781-2797
    • Aarabi, A.1    Grebe, R.2    Wallois, F.3
  • 10
    • 84857527567 scopus 로고    scopus 로고
    • Instantaneous measure of EEG channel importance for improved patient-adaptive neonatal seizure detection
    • Temko A, Lightbody G, Thomas E, Boylan G and Marnane W 2012 Instantaneous measure of EEG channel importance for improved patient-adaptive neonatal seizure detection IEEE Trans. Biomed. Eng. 59 717-27
    • (2012) IEEE Trans. Biomed. Eng. , vol.59 , pp. 717-727
    • Temko, A.1    Lightbody, G.2    Thomas, E.3    Boylan, G.4    Marnane, W.5
  • 11
    • 84857650490 scopus 로고    scopus 로고
    • The temporal evolution of electrographic seizure burden in neonatal hypoxic ischemic encephalopathy
    • Lynch N, Stevenson N, Livingstone V, Rennie J and Boylan G 2012 The temporal evolution of electrographic seizure burden in neonatal hypoxic ischemic encephalopathy Epilepsia 53 549-57
    • (2012) Epilepsia , vol.53 , pp. 549-557
    • Lynch, N.1    Stevenson, N.2    Livingstone, V.3    Rennie, J.4    Boylan, G.5
  • 14
    • 79957625121 scopus 로고    scopus 로고
    • The use of conventional EEG for the assessment of hypoxic ischaemic encephalopathy in the newborn: A review
    • Walsh B, Murray D and Boylan G 2011 The use of conventional EEG for the assessment of hypoxic ischaemic encephalopathy in the newborn: a review Clin. Neurophysiol. 122 1284-94
    • (2011) Clin. Neurophysiol. , vol.122 , pp. 1284-1294
    • Walsh, B.1    Murray, D.2    Boylan, G.3
  • 15
    • 70349262525 scopus 로고    scopus 로고
    • Early EEG findings in hypoxic-ischaemic encephalopathy predict outcome at 2 years
    • Murray D, Boylan G, Ryan C and Connolly S 2009 Early EEG findings in hypoxic-ischaemic encephalopathy predict outcome at 2 years Pediatrics 124 449-67
    • (2009) Pediatrics , vol.124 , pp. 449-467
    • Murray, D.1    Boylan, G.2    Ryan, C.3    Connolly, S.4
  • 17
    • 0003243224 scopus 로고    scopus 로고
    • Probabilistic outputs for SVM and comparison to regularized likelihood methods
    • ed A Smola, P Bartlett, B Scholkopf and D Schuurmans (Cambridge, MA: MIT)
    • Platt J 1999 Probabilistic outputs for SVM and comparison to regularized likelihood methods Advances in Large Margin Classifiers ed A Smola, P Bartlett, B Scholkopf and D Schuurmans (Cambridge, MA: MIT)
    • (1999) Advances in Large Margin Classifiers
    • Platt, J.1
  • 20
    • 0036630603 scopus 로고    scopus 로고
    • Areas beneath the relative operating characteristics (ROC) and relative operating levels (ROL) curves: Statistical significance and interpretation
    • DOI 10.1256/003590002320603584
    • Mason S and Graham N 2002 Areas beneath the relative operating characteristics (ROC) and relative operating levels (ROL) curves: statistical significance and interpretation Q. J. R. Meteorol. Soc. 128 2145-66 (Pubitemid 34995960)
    • (2002) Quarterly Journal of the Royal Meteorological Society , vol.128 , Issue.584 PART B , pp. 2145-2166
    • Mason, S.J.1    Graham, N.E.2
  • 21
    • 0020083498 scopus 로고
    • The meaning and use of the area under a receiver operating characteristic (ROC) curve
    • Hanley J and McNeil B 1982 The meaning and use of the area under a receiver operating characteristic (ROC) curve Radiology 143 29-36 (Pubitemid 12142173)
    • (1982) Radiology , vol.143 , Issue.1 , pp. 29-36
    • Hanley, J.A.1    McNeil, B.J.2
  • 22
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley J and McNeil B 1983 A method of comparing the areas under receiver operating characteristic curves derived from the same cases Radiology 148 839-43 (Pubitemid 13033817)
    • (1983) Radiology , vol.148 , Issue.3 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 23
    • 0001036819 scopus 로고
    • A class of distributions which includes the normal ones
    • Azzalini A 1985 A class of distributions which includes the normal ones Scand. J. Statist. 12 171-78
    • (1985) Scand. J. Statist. , vol.12 , pp. 171-178
    • Azzalini, A.1
  • 24
    • 34548534041 scopus 로고    scopus 로고
    • Characterization of neonatal seizures by conventional EEG and single-channel EEG
    • DOI 10.1016/j.clinph.2007.06.061, PII S1388245707003938
    • Shellhaas R and Clancy R 2007 Characterization of neonatal seizures by conventional EEG and single-channel EEG Clin. Neurophysiol. 118 2156-61 (Pubitemid 47386042)
    • (2007) Clinical Neurophysiology , vol.118 , Issue.10 , pp. 2156-2161
    • Shellhaas, R.A.1    Clancy, R.R.2
  • 25
    • 61849179301 scopus 로고    scopus 로고
    • Limitations of single-channel EEG on the forehead for neonatal seizure detection
    • Wusthoff C, Shellhaas R and Clancy R 2009 Limitations of single-channel EEG on the forehead for neonatal seizure detection J. Perinatol. 29 237-42
    • (2009) J. Perinatol. , vol.29 , pp. 237-242
    • Wusthoff, C.1    Shellhaas, R.2    Clancy, R.3
  • 28
    • 78751612420 scopus 로고    scopus 로고
    • Development of neonatal seizure detectors: An elusive target and stretching measuring tapes
    • Vanhatalo S 2011 Development of neonatal seizure detectors: an elusive target and stretching measuring tapes Clin. Neurophysiol. 122 435-7
    • (2011) Clin. Neurophysiol. , vol.122 , pp. 435-437
    • Vanhatalo, S.1
  • 29
    • 82155188424 scopus 로고    scopus 로고
    • EEG signal description with spectral-envelope-based speech recognition features for detection of neonatal seizures
    • Temko A, Nadeu C, Marnane W, Boylan G and Lightbody G 2011 EEG signal description with spectral-envelope-based speech recognition features for detection of neonatal seizures IEEE Trans. Inf. Technol. Biomed. 15 839-47
    • (2011) IEEE Trans. Inf. Technol. Biomed. , vol.15 , pp. 839-847
    • Temko, A.1    Nadeu, C.2    Marnane, W.3    Boylan, G.4    Lightbody, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.