-
1
-
-
33645470121
-
Prevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study
-
Heeringa J., Van der Kuip D.A.M., Hofman A., Kors J.A., Van Herpen G., Stricker B.H., et al. Prevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study. Eur Heart J 2006, 27(8):949-953.
-
(2006)
Eur Heart J
, vol.27
, Issue.8
, pp. 949-953
-
-
Heeringa, J.1
Van der Kuip, D.A.M.2
Hofman, A.3
Kors, J.A.4
Van Herpen, G.5
Stricker, B.H.6
-
2
-
-
0035832261
-
Prevalence of diagnosed atrial fibrillation in adults
-
Go A.S., Hylek E.M., Phillips K.A., Chang Y., Henault L.E., Selby J.V., et al. Prevalence of diagnosed atrial fibrillation in adults. JAMA 2001, 285(18):2370-2375.
-
(2001)
JAMA
, vol.285
, Issue.18
, pp. 2370-2375
-
-
Go, A.S.1
Hylek, E.M.2
Phillips, K.A.3
Chang, Y.4
Henault, L.E.5
Selby, J.V.6
-
3
-
-
0034877715
-
Trends in the prevalence and management of atrial fibrillation in general practice in England and Wales, 1994-1998: analysis of data from the general practice research database
-
Majeed A., Moser K., Carroll K. Trends in the prevalence and management of atrial fibrillation in general practice in England and Wales, 1994-1998: analysis of data from the general practice research database. Heart 2001, 86(3):284-288.
-
(2001)
Heart
, vol.86
, Issue.3
, pp. 284-288
-
-
Majeed, A.1
Moser, K.2
Carroll, K.3
-
4
-
-
33646510707
-
Atrial fibrillation ablation: reaching the mainstream
-
Fisher J.D., Spinelli M.A., Mookherjee D., Krumerman A.K., Palma E.C. Atrial fibrillation ablation: reaching the mainstream. Pacing Clin Electrophysiol 2006, 29:523-537.
-
(2006)
Pacing Clin Electrophysiol
, vol.29
, pp. 523-537
-
-
Fisher, J.D.1
Spinelli, M.A.2
Mookherjee, D.3
Krumerman, A.K.4
Palma, E.C.5
-
5
-
-
0038300657
-
Mortality, morbidity and quality of life after circumferential pulmonary vein ablation for atrial fibrillation: outcomes from a controlled nonrandomised long term study
-
Papone C., Rosanio S., Augello, Gallus G., Vicedomini G., Mazzone P., et al. Mortality, morbidity and quality of life after circumferential pulmonary vein ablation for atrial fibrillation: outcomes from a controlled nonrandomised long term study. J Am Coll Cardiol 2003, 42:185-197.
-
(2003)
J Am Coll Cardiol
, vol.42
, pp. 185-197
-
-
Papone, C.1
Rosanio, S.2
Augello Gallus, G.3
Vicedomini, G.4
Mazzone, P.5
-
6
-
-
20144363969
-
Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation
-
Cappato R., Calkins H., Chen S.A., Davies W., Iesaka Y., Kalman J., et al. Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation 2005, 111:1100-1105.
-
(2005)
Circulation
, vol.111
, pp. 1100-1105
-
-
Cappato, R.1
Calkins, H.2
Chen, S.A.3
Davies, W.4
Iesaka, Y.5
Kalman, J.6
-
7
-
-
0037036848
-
Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: impact of different catheter technologies
-
Marrouche N.F., Dresing T., Cole C., Bash D., Saad E., Balaban K., et al. Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: impact of different catheter technologies. J Am Coll Cardiol 2002, 40:464-474.
-
(2002)
J Am Coll Cardiol
, vol.40
, pp. 464-474
-
-
Marrouche, N.F.1
Dresing, T.2
Cole, C.3
Bash, D.4
Saad, E.5
Balaban, K.6
-
8
-
-
47149112945
-
Circumferential pulmonary vein isolation with the cryoballoon technique: results from a prospective 3-center study
-
Neumann T., Vogt J., Schumacher B., Dorszewski A., Kuniss M., Neuser H., et al. Circumferential pulmonary vein isolation with the cryoballoon technique: results from a prospective 3-center study. J Am Coll Cardiol 2008, 52:273-278.
-
(2008)
J Am Coll Cardiol
, vol.52
, pp. 273-278
-
-
Neumann, T.1
Vogt, J.2
Schumacher, B.3
Dorszewski, A.4
Kuniss, M.5
Neuser, H.6
-
9
-
-
34548803112
-
Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome
-
Van Belle Y., Janse P., Rivero-Ayerza M.J., Thornton A.S., Jessurun E.R., Theuns D., et al. Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. Eur Heart J 2007, 28(18):2231-2237.
-
(2007)
Eur Heart J
, vol.28
, Issue.18
, pp. 2231-2237
-
-
Van Belle, Y.1
Janse, P.2
Rivero-Ayerza, M.J.3
Thornton, A.S.4
Jessurun, E.R.5
Theuns, D.6
-
10
-
-
64949092842
-
The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study
-
Chun K.R., Schmidt B., Metzner A., Tilz R., Zerm T., Koster I., et al. The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. Eur Heart J 2009, 30(6):636-637.
-
(2009)
Eur Heart J
, vol.30
, Issue.6
, pp. 636-637
-
-
Chun, K.R.1
Schmidt, B.2
Metzner, A.3
Tilz, R.4
Zerm, T.5
Koster, I.6
-
11
-
-
55249110821
-
Acute and clinical effects of cryoballoon pulmonary vein isolation in patients with symptomatic paroxysmal and persistent atrial fibrillation
-
Malmborg H., Lonnerholm S., Blomstrom-Lundqvist C. Acute and clinical effects of cryoballoon pulmonary vein isolation in patients with symptomatic paroxysmal and persistent atrial fibrillation. Europace 2008, 10:1277-1280.
-
(2008)
Europace
, vol.10
, pp. 1277-1280
-
-
Malmborg, H.1
Lonnerholm, S.2
Blomstrom-Lundqvist, C.3
-
12
-
-
33751528863
-
Cryoablation versus radiofrequency ablation in the treatment of atrial flutter trial (CRAAFT)
-
Collins N.J., Barlow M., Varghese P. Cryoablation versus radiofrequency ablation in the treatment of atrial flutter trial (CRAAFT). J Interv Card Electrophysiol 2006, 16:1-5.
-
(2006)
J Interv Card Electrophysiol
, vol.16
, pp. 1-5
-
-
Collins, N.J.1
Barlow, M.2
Varghese, P.3
-
13
-
-
78650901054
-
2011 ACCF/AHA/HRS focused update on the management of patients with atrial fibrillation (updating the 2006 guideline): a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines
-
Fuster V., Ryden L.E., Cannom D.S., Le Heuzey J.Y., Crijns H.J., Lowe J.E., et al. 2011 ACCF/AHA/HRS focused update on the management of patients with atrial fibrillation (updating the 2006 guideline): a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol 2011, 57:223-242.
-
(2011)
J Am Coll Cardiol
, vol.57
, pp. 223-242
-
-
Fuster, V.1
Ryden, L.E.2
Cannom, D.S.3
Le Heuzey, J.Y.4
Crijns, H.J.5
Lowe, J.E.6
-
14
-
-
34547903168
-
HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up: a report of the Heart Rhythm Society (HRS) task force on catheter and surgical ablation of atrial fibrillation developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS)
-
Calkins H., Brugada J., Packer D.L., Cappato R., Chen S.A., Crijns H.J., et al. HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for personnel, policy, procedures and follow-up: a report of the Heart Rhythm Society (HRS) task force on catheter and surgical ablation of atrial fibrillation developed in partnership with the European Heart Rhythm Association (EHRA) and the European Cardiac Arrhythmia Society (ECAS); in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), and the Society of Thoracic Surgeons (STS). Endorsed and approved by the governing bodies of the American College of Cardiology, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, and the Heart Rhythm Society. Europace 2007, 9:335-379.
-
(2007)
Europace
, vol.9
, pp. 335-379
-
-
Calkins, H.1
Brugada, J.2
Packer, D.L.3
Cappato, R.4
Chen, S.A.5
Crijns, H.J.6
-
15
-
-
79957931944
-
Efficacy and safety of pulmonary vein isolation by cryoablation for the treatment of paroxysmal and persistent atrial fibrillation
-
Defaye P., Kane A., Chaib A., Jacon P. Efficacy and safety of pulmonary vein isolation by cryoablation for the treatment of paroxysmal and persistent atrial fibrillation. Europace 2011, 13(6):789-795.
-
(2011)
Europace
, vol.13
, Issue.6
, pp. 789-795
-
-
Defaye, P.1
Kane, A.2
Chaib, A.3
Jacon, P.4
-
16
-
-
84864692195
-
Trends in atrial fibrillation ablation: have we maximized the current paradigms?
-
Winkle R.A., Hardwin-Mead R., Engel G., Kong M.H., Patrawala R.A. Trends in atrial fibrillation ablation: have we maximized the current paradigms?. J Interv Card Electrophysiol 2012, 10.1007/s10840-011-9662-1.
-
(2012)
J Interv Card Electrophysiol
-
-
Winkle, R.A.1
Hardwin-Mead, R.2
Engel, G.3
Kong, M.H.4
Patrawala, R.A.5
-
17
-
-
84864717951
-
Impact of preprocedural imaging on outcomes of catheter ablation in patients with atrial fibrillation
-
Yokokawa M., Olgun H., Sundaram B., Chugh A., Latchamsetty R., Good E., et al. Impact of preprocedural imaging on outcomes of catheter ablation in patients with atrial fibrillation. J Interv Card Electrophysiol 2012, 10.1007/s10840-011-9660-3.
-
(2012)
J Interv Card Electrophysiol
-
-
Yokokawa, M.1
Olgun, H.2
Sundaram, B.3
Chugh, A.4
Latchamsetty, R.5
Good, E.6
-
19
-
-
77649308976
-
Updated worldwide survey on the methods, efficacy and safety of catheter ablation for human atrial fibrillation
-
Cappato R., Calkins H., Chen S.A., Davies W., Iesaka Y., Kalman J., et al. Updated worldwide survey on the methods, efficacy and safety of catheter ablation for human atrial fibrillation. Circulation 2009, 3:32-38.
-
(2009)
Circulation
, vol.3
, pp. 32-38
-
-
Cappato, R.1
Calkins, H.2
Chen, S.A.3
Davies, W.4
Iesaka, Y.5
Kalman, J.6
-
20
-
-
77955240556
-
Esophageal endoscopy results after pulmonary vein isolation using the single big cryoballoon technique
-
Furnkranz A., Chun K.R.J., Metzner A., Nuyens D., Schmidt B., Burchard A., et al. Esophageal endoscopy results after pulmonary vein isolation using the single big cryoballoon technique. J Cardiovasc Electrophysiol 2010, 21(8):869-874.
-
(2010)
J Cardiovasc Electrophysiol
, vol.21
, Issue.8
, pp. 869-874
-
-
Furnkranz, A.1
Chun, K.R.J.2
Metzner, A.3
Nuyens, D.4
Schmidt, B.5
Burchard, A.6
-
21
-
-
67549124646
-
Esophagoscopy following cryoballoon pulmonary vein ablation: Can the promise be met?
-
Lickfett L. Esophagoscopy following cryoballoon pulmonary vein ablation: Can the promise be met?. Heart Rhythm 2009, 6(7):970-971.
-
(2009)
Heart Rhythm
, vol.6
, Issue.7
, pp. 970-971
-
-
Lickfett, L.1
-
22
-
-
33744971593
-
Phrenic nerve injury after atrial fibrillation catheter ablation
-
Sacher F., Monahan K.H., Thomas S.P., Davidson N., Adragao P., Sanders P., et al. Phrenic nerve injury after atrial fibrillation catheter ablation. J Am Coll Cardiol 2006, 47:2498-2503.
-
(2006)
J Am Coll Cardiol
, vol.47
, pp. 2498-2503
-
-
Sacher, F.1
Monahan, K.H.2
Thomas, S.P.3
Davidson, N.4
Adragao, P.5
Sanders, P.6
-
23
-
-
70450217281
-
Incidence and predictors of periprocedural cerebrovascular accident in patients undergoing catheter ablation of atrial fibrillation
-
Scherr D., Sharma K., Dalal D., Spragg D., Chilukuri K., Cheng A., et al. Incidence and predictors of periprocedural cerebrovascular accident in patients undergoing catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol 2009, 20:1357-1363.
-
(2009)
J Cardiovasc Electrophysiol
, vol.20
, pp. 1357-1363
-
-
Scherr, D.1
Sharma, K.2
Dalal, D.3
Spragg, D.4
Chilukuri, K.5
Cheng, A.6
-
24
-
-
79959247594
-
Prevalence and predictors of complications of radiofrequency catheter ablation for atrial fibrillation
-
Baman T., Jongnarangsin K., Chugh A., Suwanagool A., Guiot A., Madenci A., et al. Prevalence and predictors of complications of radiofrequency catheter ablation for atrial fibrillation. J Cardiovasc Electrophysiol 2011, 22:621-727.
-
(2011)
J Cardiovasc Electrophysiol
, vol.22
, pp. 621-727
-
-
Baman, T.1
Jongnarangsin, K.2
Chugh, A.3
Suwanagool, A.4
Guiot, A.5
Madenci, A.6
-
25
-
-
79961204469
-
Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon
-
Gaita F., Leclercq J.F., Schumacher B. Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon. J Cardiovasc Electrophysiol 2011, 10.1111/j.1540-8167.
-
(2011)
J Cardiovasc Electrophysiol
-
-
Gaita, F.1
Leclercq, J.F.2
Schumacher, B.3
|