메뉴 건너뛰기




Volumn 44, Issue , 2012, Pages 281-290

FBG based strain monitoring in the rehabilitation of a centenary metallic bridge

Author keywords

Bridge rehabilitation; FBG sensors; Strain measurement; Structural monitoring

Indexed keywords

19TH CENTURY; BRIDGE REHABILITATION; BUILDING PROCESS; COMPLEX TASK; FBG SENSOR; FIBER BRAGG GRATING SENSORS; METALLIC BRIDGE; MONITORING PROGRAMS; PORTUGAL; SAFETY VERIFICATION; STRAIN MONITORING; STRUCTURAL BEHAVIORS; STRUCTURAL CONDITION; STRUCTURAL MONITORING; STRUCTURAL REHABILITATION; STRUCTURAL SYSTEMS;

EID: 84863821098     PISSN: 01410296     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.engstruct.2012.05.040     Document Type: Article
Times cited : (53)

References (31)
  • 1
    • 33748968652 scopus 로고    scopus 로고
    • Considerations on recent trends in, and future prospects of, steel bridge construction in Japan
    • Kitada T. Considerations on recent trends in, and future prospects of, steel bridge construction in Japan. J Constr Steel Res 2006, 62(11):1192-1198.
    • (2006) J Constr Steel Res , vol.62 , Issue.11 , pp. 1192-1198
    • Kitada, T.1
  • 2
    • 33747428365 scopus 로고    scopus 로고
    • Bridge instrumentation and monitoring for structural diagnostics
    • Farhey D.N. Bridge instrumentation and monitoring for structural diagnostics. Struct Health Monit 2005, 4(4):301-318.
    • (2005) Struct Health Monit , vol.4 , Issue.4 , pp. 301-318
    • Farhey, D.N.1
  • 3
    • 30844460778 scopus 로고    scopus 로고
    • Validated analysis and strengthening of a 19th century railway bridge
    • Ermopoulos J., Spyrakos C.C. Validated analysis and strengthening of a 19th century railway bridge. Eng Struct 2006, 28(5):783-792.
    • (2006) Eng Struct , vol.28 , Issue.5 , pp. 783-792
    • Ermopoulos, J.1    Spyrakos, C.C.2
  • 5
    • 39349085933 scopus 로고    scopus 로고
    • Performance evaluation through field testing of century-old railroad truss bridge
    • DelGrego M.R., Culmo M.P., DeWolf J.T. Performance evaluation through field testing of century-old railroad truss bridge. J Bridge Eng 2008, 13(2):132-138.
    • (2008) J Bridge Eng , vol.13 , Issue.2 , pp. 132-138
    • DelGrego, M.R.1    Culmo, M.P.2    DeWolf, J.T.3
  • 6
    • 2342441073 scopus 로고    scopus 로고
    • Condition assessment and retrofit of a historic steel-truss railway bridge
    • Spyrakos C.C., Raftoyiannis I.G., Ermopoulos J. Condition assessment and retrofit of a historic steel-truss railway bridge. J Constr Steel Res 2004, 60(8):1213-1225.
    • (2004) J Constr Steel Res , vol.60 , Issue.8 , pp. 1213-1225
    • Spyrakos, C.C.1    Raftoyiannis, I.G.2    Ermopoulos, J.3
  • 7
    • 0032626521 scopus 로고    scopus 로고
    • Short-term strain monitoring of bridge structures
    • Sartor R.R., Culmo M.P., DeWolf J.T. Short-term strain monitoring of bridge structures. J Bridge Eng 1999, 4(3):157-164.
    • (1999) J Bridge Eng , vol.4 , Issue.3 , pp. 157-164
    • Sartor, R.R.1    Culmo, M.P.2    DeWolf, J.T.3
  • 9
    • 0031212257 scopus 로고    scopus 로고
    • Fiber Bragg grating technology fundamentals and overview
    • Hill K.O., Meltz G. Fiber Bragg grating technology fundamentals and overview. J Lightwave Technol 1997, 15(8):1263-1276.
    • (1997) J Lightwave Technol , vol.15 , Issue.8 , pp. 1263-1276
    • Hill, K.O.1    Meltz, G.2
  • 11
    • 84864813445 scopus 로고    scopus 로고
    • Overview of fiber optic sensors for NDT applications.In: Proceedings of IV NDT panamerican conference;
    • Méndez A, Graver T. Overview of fiber optic sensors for NDT applications. In: Proceedings of IV NDT panamerican conference; 2007.
    • (2007)
    • Méndez, A.1    Graver, T.2
  • 12
    • 34547901384 scopus 로고    scopus 로고
    • Practical implementation of optical fiber sensors in civil structural health monitoring
    • Ansari F. Practical implementation of optical fiber sensors in civil structural health monitoring. J Intell Mater Syst Struct 2007, 18(8):879-889.
    • (2007) J Intell Mater Syst Struct , vol.18 , Issue.8 , pp. 879-889
    • Ansari, F.1
  • 13
    • 84864819125 scopus 로고    scopus 로고
    • FS6200 - Poyimide strain sensor.
    • FS6200 - Poyimide strain sensor. http://www.fibersensing.com.
  • 14
    • 84889495202 scopus 로고    scopus 로고
    • Fibre optic methods for structural health monitoring. John Wiley & Sons, Inc.;
    • Glisic B, Inaudi D. Fibre optic methods for structural health monitoring. John Wiley & Sons, Inc.; 2007.
    • (2007)
    • Glisic, B.1    Inaudi, D.2
  • 15
    • 84864813446 scopus 로고    scopus 로고
    • Installation, use and repair of fibre optic sensors. ISIS Canada;
    • Tennyson RC. Installation, use and repair of fibre optic sensors. ISIS Canada; 2001.
    • (2001)
    • Tennyson, R.C.1
  • 16
    • 34047114730 scopus 로고    scopus 로고
    • Civionics specifications for fiber optic sensors for structural health monitoring
    • Rivera E., Mufti A.A., Thomson DJ. Civionics specifications for fiber optic sensors for structural health monitoring. Arab J Sci Eng 2006, 31(1C):241-248.
    • (2006) Arab J Sci Eng , vol.31 C , Issue.1 , pp. 241-248
    • Rivera, E.1    Mufti, A.A.2    Thomson, D.J.3
  • 17
    • 84864802655 scopus 로고
    • Experimental stress analysis. 2nd ed. McGraw-Hill;
    • Dally JE, Riley WF. Experimental stress analysis. 2nd ed. McGraw-Hill; 1978.
    • (1978)
    • Dally, J.E.1    Riley, W.F.2
  • 18
    • 84864813444 scopus 로고    scopus 로고
    • Surface preparation for strain gage bonding; 2010.
    • Surface preparation for strain gage bonding; 2010. http://www.vishaypg.com.
  • 19
    • 84864819123 scopus 로고    scopus 로고
    • Strain sensor installation guide; 2010.
    • Strain sensor installation guide; 2010. http://www.fibersensing.com.
  • 20
    • 0001544659 scopus 로고    scopus 로고
    • Simultaneous measurement of temperature and strain using two fiber Bragg gratings embedded in a glass tube
    • Song M.H., Lee S.B., Choi S.S., Lee B.H. Simultaneous measurement of temperature and strain using two fiber Bragg gratings embedded in a glass tube. Opt Fiber Technol 1997, 3(2):194-196.
    • (1997) Opt Fiber Technol , vol.3 , Issue.2 , pp. 194-196
    • Song, M.H.1    Lee, S.B.2    Choi, S.S.3    Lee, B.H.4
  • 21
    • 17044387859 scopus 로고    scopus 로고
    • Growing market acceptance for fiber-optic solutions in civil structures. In: Proceedings of SPIE - the International Society for Optical Engineering;
    • Graver T, Inaudi D, Doornink J. Growing market acceptance for fiber-optic solutions in civil structures. In: Proceedings of SPIE - the International Society for Optical Engineering; 2004. p. 44-55.
    • (2004) , pp. 44-55
    • Graver, T.1    Inaudi, D.2    Doornink, J.3
  • 22
    • 0029359715 scopus 로고
    • An overview of fiber-optic sensors
    • Udd E. An overview of fiber-optic sensors. Rev Sci Instrum 1995, 66(8):4015-4030.
    • (1995) Rev Sci Instrum , vol.66 , Issue.8 , pp. 4015-4030
    • Udd, E.1
  • 23
    • 84864802653 scopus 로고    scopus 로고
    • Structural monitoring with fiber optic technology. Academic Press;
    • Measures RM. Structural monitoring with fiber optic technology. Academic Press; 2001.
    • (2001)
    • Measures, R.M.1
  • 24
    • 79955524677 scopus 로고    scopus 로고
    • Cost forecasting of passive components for optical fiber network deployments
    • Artundo I., Tymecki A., Ortego E., Ortega B. Cost forecasting of passive components for optical fiber network deployments. Opt Fiber Technol 2011, 17(3):218-226.
    • (2011) Opt Fiber Technol , vol.17 , Issue.3 , pp. 218-226
    • Artundo, I.1    Tymecki, A.2    Ortego, E.3    Ortega, B.4
  • 25
    • 84864802654 scopus 로고    scopus 로고
    • REFER. Eiffel bridge over Lima river. Direçao de comunica̧ao e imagem; 2007 [in Portuguese].
    • REFER. Eiffel bridge over Lima river. Direçao de comunica̧ao e imagem; 2007 [in Portuguese].
  • 26
    • 84864819122 scopus 로고    scopus 로고
    • Lisconcebe. Enlargement and rehabilitation of the road deck of Eiffel Bridge, over Lima river
    • in Viana do Castelo - descriptive document of the implementation project. Technical Report; 2007 [in Portuguese].
    • Lisconcebe. Enlargement and rehabilitation of the road deck of Eiffel Bridge, over Lima river, in Viana do Castelo - descriptive document of the implementation project. Technical Report; 2007 [in Portuguese].
  • 27
    • 84864803873 scopus 로고
    • DIN 1025-1. Hot rolled I and H sections (I series): Dimensions, mass and static parameters;
    • DIN 1025-1. Hot rolled I and H sections (I series): Dimensions, mass and static parameters; 1995.
    • (1995)
  • 28
    • 84864802652 scopus 로고
    • Euronorm 53. Hot-rolled Broad Flanged I-beams (wide-flanged I-beams) with parallel flange facings;
    • Euronorm 53. Hot-rolled Broad Flanged I-beams (wide-flanged I-beams) with parallel flange facings; 1962.
    • (1962)
  • 29
    • 84864813441 scopus 로고    scopus 로고
    • Final load test of Eiffel Bridge. Technical report, LABEST/FEUP, Porto; 2008 [in Portuguese].
    • Cavadas F, Rodrigues C, Félix C, Figueiras J. Final load test of Eiffel Bridge. Technical report, LABEST/FEUP, Porto; 2008 [in Portuguese].
    • Cavadas, F.1    Rodrigues, C.2    Félix, C.3    Figueiras, J.4
  • 30
    • 84863907367 scopus 로고    scopus 로고
    • Analysis and monitoring of old steel bridges behavior - Eiffel Bridge
    • Master in civil engineering dissertation. Faculdade de Engenharia, Universidade do Porto, Porto; 2008 [in Portuguese].
    • Cavadas F. Analysis and monitoring of old steel bridges behavior - Eiffel Bridge. Master in civil engineering dissertation. Faculdade de Engenharia, Universidade do Porto, Porto; 2008 [in Portuguese].
    • Cavadas, F.1
  • 31
    • 84864813442 scopus 로고    scopus 로고
    • Assessment of road pavement solution of Eiffel Bridge, in Viana do Castelo. Technical report, LABEST/FEUP, Porto; 2011 [in Portuguese].
    • Figueiras J, Juvandes L, Marques AT, Mendes A. Assessment of road pavement solution of Eiffel Bridge, in Viana do Castelo. Technical report, LABEST/FEUP, Porto; 2011 [in Portuguese].
    • Figueiras, J.1    Juvandes, L.2    Marques, A.T.3    Mendes, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.