메뉴 건너뛰기




Volumn 22, Issue SUPPLEMENT N. 7, 2012, Pages

Biomechanical properties of axially myopic cornea

Author keywords

Axial length; Corneal hysteresis; Corneal resistance factor; Intraocular pressure; Ocular response analyzer

Indexed keywords

ADULT; ARTICLE; AXIAL LENGTH; BIOMECHANICS; CONTROLLED STUDY; CORNEA; CORNEAL COMPENSATED INTRAOCULAR PRESSURE; CORNEAL HYSTERESIS; CORNEAL RESISTANCE FACTOR; FEMALE; HUMAN; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; MALE; MYOPIA; PRIORITY JOURNAL; VISUAL SYSTEM PARAMETERS; COMPARATIVE STUDY; ELASTICITY; ELASTOGRAPHY; EYE AXIS LENGTH; PATHOPHYSIOLOGY; PHYSIOLOGY; VISUAL ACUITY; VISUAL SYSTEM EXAMINATION;

EID: 84863740164     PISSN: 11206721     EISSN: None     Source Type: Journal    
DOI: 10.5301/ejo.5000010     Document Type: Article
Times cited : (18)

References (23)
  • 1
    • 47749089022 scopus 로고    scopus 로고
    • Corneal biomechanical properties in primary open angle glaucoma and normal tension glaucoma
    • Ang GS, Bochmann F, Townend J, Azuara-Blanco A. Corneal biomechanical properties in primary open angle glaucoma and normal tension glaucoma. J Glaucoma 2008; 17: 259-62.
    • (2008) J Glaucoma , vol.17 , pp. 259-262
    • Ang, G.S.1    Bochmann, F.2    Townend, J.3    Azuara-Blanco, A.4
  • 2
    • 62649160370 scopus 로고    scopus 로고
    • Effect of diabetes mellitus on biomechanical parameters of the cornea
    • Goldich Y, Barkana Y, Gerber Y, et al. Effect of diabetes mellitus on biomechanical parameters of the cornea. J Cataract Refract Surg 2009; 35: 715-9.
    • (2009) J Cataract Refract Surg , vol.35 , pp. 715-719
    • Goldich, Y.1    Barkana, Y.2    Gerber, Y.3
  • 3
    • 13844317411 scopus 로고    scopus 로고
    • Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    • Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 2005; 31: 156-62.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 156-162
    • Luce, D.A.1
  • 4
    • 33750995542 scopus 로고    scopus 로고
    • The use of the Reichert ocular response analyser to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyes
    • Shah S, Laiquzzaman M, Cunliffe I, Mantry S. The use of the Reichert ocular response analyser to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyes. Cont Lens Anterior Eye 2006; 29: 257-62.
    • (2006) Cont Lens Anterior Eye , vol.29 , pp. 257-262
    • Shah, S.1    Laiquzzaman, M.2    Cunliffe, I.3    Mantry, S.4
  • 5
    • 33748924156 scopus 로고    scopus 로고
    • Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer
    • Medeiros FA, Weinreb RN. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer. J Glaucoma 2006; 15: 364-70.
    • (2006) J Glaucoma , vol.15 , pp. 364-370
    • Medeiros, F.A.1    Weinreb, R.N.2
  • 6
    • 53149120317 scopus 로고    scopus 로고
    • Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children
    • Lim L, Gazzard G, Chan YH, et al. Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children. Invest Ophthalmol Vis Sci 2008; 49: 3852-7.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 3852-3857
    • Lim, L.1    Gazzard, G.2    Chan, Y.H.3
  • 7
    • 59849117436 scopus 로고    scopus 로고
    • Biomechanics of the sclera in myopia: Extracellular and cellular factors
    • McBrien NA, Jobling AI, Gentle A. Biomechanics of the sclera in myopia: Extracellular and cellular factors. Optometry and Vision Science 2009; 86: 23-30.
    • (2009) Optometry and Vision Science , vol.86 , pp. 23-30
    • McBrien, N.A.1    Jobling, A.I.2    Gentle, A.3
  • 8
    • 0030273711 scopus 로고    scopus 로고
    • Scleral matrix metalloproteinases, serine proteinase activity and hydrational capacity are increased in myopia induced by retinal image degradation
    • Jones BE, Thompson EW, Hodos W, Waldbillig RJ, Chader GJ. Scleral matrix metalloproteinases, serine proteinase activity and hydrational capacity are increased in myopia induced by retinal image degradation. Exp Eye Res 1996; 63(4): 369-81.
    • (1996) Exp Eye Res , vol.63 , Issue.4 , pp. 369-381
    • Jones, B.E.1    Thompson, E.W.2    Hodos, W.3    Waldbillig, R.J.4    Chader, G.J.5
  • 9
    • 0026749095 scopus 로고
    • Pathologic findings in pathologic myopia
    • Grossniklaus HE, Green WR. Pathologic findings in pathologic myopia. Retina 1992; 12: 127-33.
    • (1992) Retina , vol.12 , pp. 127-133
    • Grossniklaus, H.E.1    Green, W.R.2
  • 10
    • 0042804923 scopus 로고    scopus 로고
    • Role of the sclera in the develop ment and pathological complications of myopia
    • McBrien NA, Gentle A. Role of the sclera in the develop ment and pathological complications of myopia. Prog Retin Eye Res 2003; 22: 307-38.
    • (2003) Prog Retin Eye Res , vol.22 , pp. 307-338
    • McBrien, N.A.1    Gentle, A.2
  • 11
    • 55449102494 scopus 로고    scopus 로고
    • Corneal biomechanics, thickness and optic disc morphology in children with optic disc tilt
    • Lim L, Gazzard G, Chan Y-H, et al. Corneal biomechanics, thickness and optic disc morphology in children with optic disc tilt. Br J Ophthalmol 2008; 92: 1461-6.
    • (2008) Br J Ophthalmol , vol.92 , pp. 1461-1466
    • Lim, L.1    Gazzard, G.2    Chan, Y.-H.3
  • 12
    • 54049152415 scopus 로고    scopus 로고
    • Ocular response analyser to assess hysteresis and corneal resistance factor in low tension, open angle glaucoma and ocular hypertension
    • Shah S, Laiquzzaman M, Mantry S, Cunliffe I. Ocular response analyser to assess hysteresis and corneal resistance factor in low tension, open angle glaucoma and ocular hypertension. Clin Experiment Ophthalmol 2008; 36: 508-13.
    • (2008) Clin Experiment Ophthalmol , vol.36 , pp. 508-513
    • Shah, S.1    Laiquzzaman, M.2    Mantry, S.3    Cunliffe, I.4
  • 13
    • 51649083685 scopus 로고    scopus 로고
    • Biomechanical properties of the cornea in high myopia
    • Shen M, Fan F, Xue A, Wang J, Zhou X, Lu F. Biomechanical properties of the cornea in high myopia. Vision Res 2008; 48: 2167-71.
    • (2008) Vision Res , vol.48 , pp. 2167-2171
    • Shen, M.1    Fan, F.2    Xue, A.3    Wang, J.4    Zhou, X.5    Lu, F.6
  • 14
    • 77954285496 scopus 로고    scopus 로고
    • Assessment of corneal biomechanical properties and intraocular pressure with the Ocular Response Analyzer in childhood myopia
    • Chang PY, Chang SW, Wang JY. Assessment of corneal biomechanical properties and intraocular pressure with the Ocular Response Analyzer in childhood myopia. Br J Ophthalmol 2010; 94: 877-81.
    • (2010) Br J Ophthalmol , vol.94 , pp. 877-881
    • Chang, P.Y.1    Chang, S.W.2    Wang, J.Y.3
  • 15
    • 43049162800 scopus 로고    scopus 로고
    • Corneal hysteresis and axial length among Chinese secondary school children: The Xichang Pediatric Refractive Error Study (X-PRES) report no. 4
    • Song Y, Congdon N, Li L, et al. Corneal hysteresis and axial length among Chinese secondary school children: the Xichang Pediatric Refractive Error Study (X-PRES) report no. 4. Am J Ophthalmol 2008; 145: 819-26.
    • (2008) Am J Ophthalmol , vol.145 , pp. 819-826
    • Song, Y.1    Congdon, N.2    Li, L.3
  • 16
    • 80052386318 scopus 로고    scopus 로고
    • Corneal biomechanics, refractive error and axial length in Chinese primary school children
    • Jan 6
    • Huang Y, Huang C, Li L, et al. Corneal biomechanics, refractive error and axial length in Chinese primary school children. Invest Ophthalmol Vis Sci Epub 2011 Jan 6.
    • (2011) Invest Ophthalmol Vis Sci Epub
    • Huang, Y.1    Huang, C.2    Li, L.3
  • 17
    • 35848966791 scopus 로고    scopus 로고
    • What biomechanical properties of the cornea are relevant for the clinician?
    • Kotecha A. What biomechanical properties of the cornea are relevant for the clinician? Surv Ophthalmol 2007; 52 (Suppl 1): 109-14.
    • (2007) Surv Ophthalmol , vol.52 , Issue.SUPPL. 1 , pp. 109-114
    • Kotecha, A.1
  • 18
    • 77954657185 scopus 로고    scopus 로고
    • Corneal biomechanical properties and intraocular pressure in high myopic anisometropia
    • Xu S, Xu A, Tao A, Wang J, Fan F, Lu F. Corneal biomechanical properties and intraocular pressure in high myopic anisometropia. Eye Contact Lens 2010; 36: 204-9.
    • (2010) Eye Contact Lens , vol.36 , pp. 204-209
    • Xu, S.1    Xu, A.2    Tao, A.3    Wang, J.4    Fan, F.5    Lu, F.6
  • 19
    • 0027153947 scopus 로고
    • Intraocular pressure in a selected sample of myopic and nonmyopic Chinese children
    • Edwards MH, Brown B. Intraocular pressure in a selected sample of myopic and nonmyopic Chinese children. Optom Vis Sci 1993; 70: 15-7.
    • (1993) Optom Vis Sci , vol.70 , pp. 15-17
    • Edwards, M.H.1    Brown, B.2
  • 20
    • 0029871910 scopus 로고    scopus 로고
    • IOP in myopic children: The relationship between increases in IOP and the development of myopia
    • Edwards MH, Brown B. IOP in myopic children: the relationship between increases in IOP and the development of myopia. Ophthalmic Physiol Opt 1996; 16: 243-6.
    • (1996) Ophthalmic Physiol Opt , vol.16 , pp. 243-246
    • Edwards, M.H.1    Brown, B.2
  • 23
    • 51649118534 scopus 로고    scopus 로고
    • Effects of aging on corneal biomechanical properties and their impact on 24-hour measurement of intraocular pressure
    • Kida T, Liu JHK, Weinreb RN. Effects of aging on corneal biomechanical properties and their impact on 24-hour measurement of intraocular pressure. Am J Ophthalmol 2008; 146: 567-72.
    • (2008) Am J Ophthalmol , vol.146 , pp. 567-572
    • Kida, T.1    Liu, J.H.K.2    Weinreb, R.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.