메뉴 건너뛰기




Volumn 22, Issue 8, 2012, Pages 781-786

Role of ultrasound compared to age-related formulas for uncuffed endotracheal intubation in a pediatric population

Author keywords

Endotracheal tube size; Minimal transverse diameter of the subglottic airway; Pediatric age based formulas; Ultrasound

Indexed keywords

AIRWAY; ARTICLE; ARTIFICIAL VENTILATION; CHILD; CLINICAL ARTICLE; CONTROLLED STUDY; ECHOGRAPHY; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; FEMALE; HUMAN; INFANT; MALE; MINIMAL TRANSVERSE DIAMETER OF THE SUBGLOTTIC AIRWAY; PRESCHOOL CHILD; PRIORITY JOURNAL;

EID: 84863726193     PISSN: 11555645     EISSN: 14609592     Source Type: Journal    
DOI: 10.1111/j.1460-9592.2012.03889.x     Document Type: Article
Times cited : (60)

References (18)
  • 1
    • 0020575457 scopus 로고
    • Incidence of aspiration with endotracheal tubes in children
    • Browning DH, Graves SA,. Incidence of aspiration with endotracheal tubes in children. J Pediatr 1983; 2: 582-584.
    • (1983) J Pediatr , vol.2 , pp. 582-584
    • Browning, D.H.1    Graves, S.A.2
  • 2
    • 78751645405 scopus 로고    scopus 로고
    • Airway injury resulting from repeated endotracheal intubation: Possible prevention strategies
    • Oshodi A, Dysart K, Cook A, et al. Airway injury resulting from repeated endotracheal intubation: possible prevention strategies. Pediatr Crit Care Med 2011; 12: e34-e39.
    • (2011) Pediatr Crit Care Med , vol.12
    • Oshodi, A.1    Dysart, K.2    Cook, A.3
  • 3
    • 0022395911 scopus 로고
    • Intraoperative aspiration in a paediatric patient
    • Roy WL,. Intraoperative aspiration in a paediatric patient. Can Anaesth Soc J 1985; 32: 639-641.
    • (1985) Can Anaesth Soc J , vol.32 , pp. 639-641
    • Roy, W.L.1
  • 4
    • 0024534750 scopus 로고
    • Decreased incidence of subglottic stenosis using an "appropriate- sized" endotracheal tube in neonates
    • Sherman JM, Nelson H,. Decreased incidence of subglottic stenosis using an "appropriate-sized" endotracheal tube in neonates. Pediatr Pulmonol 1989; 6: 183-185.
    • (1989) Pediatr Pulmonol , vol.6 , pp. 183-185
    • Sherman, J.M.1    Nelson, H.2
  • 5
    • 1542709296 scopus 로고    scopus 로고
    • Laryngeal damage due to an unexpectedly large and inappropriately designed cuffed pediatric tracheal tube in a 13-month-old child
    • Dillier CM, Trachsel D, Baulig W, et al. Laryngeal damage due to an unexpectedly large and inappropriately designed cuffed pediatric tracheal tube in a 13-month-old child. Can J Anaesth 2004; 51: 72-75.
    • (2004) Can J Anaesth , vol.51 , pp. 72-75
    • Dillier, C.M.1    Trachsel, D.2    Baulig, W.3
  • 6
    • 33646878095 scopus 로고    scopus 로고
    • Consensus on science with treatment recommendations for pediatric and neonatal patients: Pediatric basic and advanced life support
    • The International Liaison Committee on Resuscitation (ILCOR)
    • The International Liaison Committee on Resuscitation (ILCOR). Consensus on science with treatment recommendations for pediatric and neonatal patients: pediatric basic and advanced life support. Pediatrics 2006; 177: 955-977.
    • (2006) Pediatrics , vol.177 , pp. 955-977
  • 8
    • 0001483599 scopus 로고
    • Pediatric formulas for the anesthesiologist
    • Cole F,. Pediatric formulas for the anesthesiologist. AMA J Dis Child 1957; 94: 672-673.
    • (1957) AMA J Dis Child , vol.94 , pp. 672-673
    • Cole, F.1
  • 9
    • 0001034329 scopus 로고
    • Endotracheal intubation
    • Motoyama E.K. ed. St Louis, MO: CV Mosby
    • Motoyama EK,. Endotracheal intubation. In:, Motoyama EK, ed. Smith's Anesthesia for Infants and Children. St Louis, MO: CV Mosby, 1990: 269-275.
    • (1990) Smith's Anesthesia for Infants and Children , pp. 269-275
    • Motoyama, E.K.1
  • 10
    • 0026710494 scopus 로고
    • Length-based endotracheal tube and emergency equipment in pediatrics
    • Luten RC, Wears RL, Broselow J, et al. Length-based endotracheal tube and emergency equipment in pediatrics. Ann Emerg Med 1992; 21: 900-904.
    • (1992) Ann Emerg Med , vol.21 , pp. 900-904
    • Luten, R.C.1    Wears, R.L.2    Broselow, J.3
  • 11
    • 0344442312 scopus 로고    scopus 로고
    • Extubation failure in pediatric intensive care: A multiple center study of risk factors and outcomes
    • Kurachek SC, Newth CJ, Quasney MW, et al. Extubation failure in pediatric intensive care: a multiple center study of risk factors and outcomes. Crit Care Med 2003; 31: 2657-2664.
    • (2003) Crit Care Med , vol.31 , pp. 2657-2664
    • Kurachek, S.C.1    Newth, C.J.2    Quasney, M.W.3
  • 12
    • 33646240861 scopus 로고    scopus 로고
    • Evaluation of a new recommendation for improved cuffed tracheal tube size selection in infants and small children
    • Salgo B, Schmitz A, Henze G, et al. Evaluation of a new recommendation for improved cuffed tracheal tube size selection in infants and small children. Acta Anaesthesiol Scand 2006; 50: 557-561.
    • (2006) Acta Anaesthesiol Scand , vol.50 , pp. 557-561
    • Salgo, B.1    Schmitz, A.2    Henze, G.3
  • 13
    • 33847214182 scopus 로고    scopus 로고
    • The feasibility of ultrasound to assess subglottic diameter
    • Lakhal K, Delplace X, Cottier JP, et al. The feasibility of ultrasound to assess subglottic diameter. Anesth Analg 2007; 104: 611-614.
    • (2007) Anesth Analg , vol.104 , pp. 611-614
    • Lakhal, K.1    Delplace, X.2    Cottier, J.P.3
  • 14
    • 0036696083 scopus 로고    scopus 로고
    • Ultrasonography and videobronchoscopy to assess the subglottic diameter in the paediatric population: A first look
    • Husein M, Manoukian JJ, Platt R, et al. Ultrasonography and videobronchoscopy to assess the subglottic diameter in the paediatric population: a first look. J Otolaryngol 2002; 31: 220-226.
    • (2002) J Otolaryngol , vol.31 , pp. 220-226
    • Husein, M.1    Manoukian, J.J.2    Platt, R.3
  • 15
    • 77957911733 scopus 로고    scopus 로고
    • Prediction of pediatric endotracheal tube size by ultrasonography
    • Shibasaki M, Nakajima Y, Ishii S, et al. Prediction of pediatric endotracheal tube size by ultrasonography. Anesthesiology 2010; 113: 819-824.
    • (2010) Anesthesiology , vol.113 , pp. 819-824
    • Shibasaki, M.1    Nakajima, Y.2    Ishii, S.3
  • 16
    • 80054827871 scopus 로고    scopus 로고
    • Usefulness of ultrasound for selecting a correctly sized uncuffed tracheal tube for paediatric patients
    • Bae JY, Byon HJ, Han SS, et al. Usefulness of ultrasound for selecting a correctly sized uncuffed tracheal tube for paediatric patients. Anaesthesia 2011; 66: 994-998.
    • (2011) Anaesthesia , vol.66 , pp. 994-998
    • Bae, J.Y.1    Byon, H.J.2    Han, S.S.3
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG,. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327: 307-310.
    • (1986) Lancet , vol.327 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 32244436671 scopus 로고    scopus 로고
    • Effects on lung function of multiple expansion thoracoplasty in children with thoracic insufficiency syndrome: A longitudinal study
    • Motoyama EK, Deeney VF, Fine GF, et al. Effects on lung function of multiple expansion thoracoplasty in children with thoracic insufficiency syndrome: A longitudinal study. Spine (Phila Pa 1976) 2006; 31: 284-290.
    • (2006) Spine (Phila Pa 1976) , vol.31 , pp. 284-290
    • Motoyama, E.K.1    Deeney, V.F.2    Fine, G.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.