메뉴 건너뛰기




Volumn 52, Issue 7, 2012, Pages 949-961

Constrained snake vs. conventional snake for carotid ultrasound automated IMT measurements on multi-center data sets

Author keywords

Atherosclerosis; Carotid intima media thickness; Constraints; Deformable parametric model; Snake

Indexed keywords

ATHEROSCLEROSIS; CAROTID INTIMA-MEDIA THICKNESS; CONSTRAINTS; PARAMETRIC MODELS; SNAKE;

EID: 84863717513     PISSN: 0041624X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultras.2012.03.005     Document Type: Article
Times cited : (37)

References (49)
  • 2
    • 64149105673 scopus 로고    scopus 로고
    • Genesis and dynamics of atherosclerotic lesions: Implications for early detection
    • J.J. Badimon, B. Ibanez, and G. Cimmino Genesis and dynamics of atherosclerotic lesions: implications for early detection Cerebrovasc. Dis. 27 Suppl 1 2009 38 47
    • (2009) Cerebrovasc. Dis. , vol.27 , Issue.SUPPL. 1 , pp. 38-47
    • Badimon, J.J.1    Ibanez, B.2    Cimmino, G.3
  • 3
    • 69849112228 scopus 로고    scopus 로고
    • Interrelationships among HDL metabolism, aging, and atherosclerosis
    • M. Walter Interrelationships among HDL metabolism, aging, and atherosclerosis Arterioscler. Thromb. Vasc. Biol. 29 2009 1244 1250
    • (2009) Arterioscler. Thromb. Vasc. Biol. , vol.29 , pp. 1244-1250
    • Walter, M.1
  • 5
    • 1542409914 scopus 로고    scopus 로고
    • Predictive value of noninvasive measures of atherosclerosis for incident myocardial infarction: The Rotterdam study
    • I.M. van der Meer, M.L. Bots, A. Hofman, A.I. del Sol, D.A. van der Kuip, and J.C. Witteman Predictive value of noninvasive measures of atherosclerosis for incident myocardial infarction: the Rotterdam study Circulation 109 2004 1089 1094
    • (2004) Circulation , vol.109 , pp. 1089-1094
    • Van Der Meer, I.M.1    Bots, M.L.2    Hofman, A.3    Del Sol, A.I.4    Van Der Kuip, D.A.5    Witteman, J.C.6
  • 6
    • 16344371798 scopus 로고    scopus 로고
    • Atherosclerosis found on carotid ultrasonography is associated with atherosclerosis on coronary intravascular ultrasonography
    • T. Ogata, M. Yasaka, M. Yamagishi, O. Seguchi, K. Nagatsuka, and K. Minematsu Atherosclerosis found on carotid ultrasonography is associated with atherosclerosis on coronary intravascular ultrasonography J. Ultrasound Med. 24 2005 469 474
    • (2005) J. Ultrasound Med. , vol.24 , pp. 469-474
    • Ogata, T.1    Yasaka, M.2    Yamagishi, M.3    Seguchi, O.4    Nagatsuka, K.5    Minematsu, K.6
  • 7
    • 79960021538 scopus 로고    scopus 로고
    • Associations of edge-detected and manual-traced common carotid intima-media thickness measurements with framingham risk factors: The multi-ethnic study of atherosclerosis
    • J.F. Polak, M.J. Pencina, D. Herrington, and D.H. O'Leary Associations of edge-detected and manual-traced common carotid intima-media thickness measurements with framingham risk factors: the multi-ethnic study of atherosclerosis Stroke 42 2011 1912 1916
    • (2011) Stroke , vol.42 , pp. 1912-1916
    • Polak, J.F.1    Pencina, M.J.2    Herrington, D.3    O'Leary, D.H.4
  • 8
    • 78649532612 scopus 로고    scopus 로고
    • Associations of carotid artery intima-media thickness (IMT) with risk factors and prevalent cardiovascular disease: Comparison of mean common carotid artery IMT with maximum internal carotid artery IMT
    • J.F. Polak, M.J. Pencina, A. Meisner, K.M. Pencina, L.S. Brown, P.A. Wolf, and R.B. D'Agostino Sr. Associations of carotid artery intima-media thickness (IMT) with risk factors and prevalent cardiovascular disease: comparison of mean common carotid artery IMT with maximum internal carotid artery IMT J. Ultrasound Med. 29 2010 1759 1768
    • (2010) J. Ultrasound Med. , vol.29 , pp. 1759-1768
    • Polak, J.F.1    Pencina, M.J.2    Meisner, A.3    Pencina, K.M.4    Brown, L.S.5    Wolf, P.A.6    D'Agostino, Sr.R.B.7
  • 9
    • 77957994285 scopus 로고    scopus 로고
    • Common carotid intima-media thickness and framingham risk score predict incident carotid atherosclerotic plaque formation: Longitudinal results from the study of health in pomerania
    • B. von Sarnowski, J. Ludemann, H. Volzke, M. Dorr, C. Kessler, and U. Schminke Common carotid intima-media thickness and framingham risk score predict incident carotid atherosclerotic plaque formation: longitudinal results from the study of health in pomerania Stroke 41 2010 2375 2377
    • (2010) Stroke , vol.41 , pp. 2375-2377
    • Von Sarnowski, B.1    Ludemann, J.2    Volzke, H.3    Dorr, M.4    Kessler, C.5    Schminke, U.6
  • 10
    • 0026499899 scopus 로고
    • Arterial wall thickness in familial hypercholesterolemia. Ultrasound measurement of intima-media thickness in the common carotid artery
    • I. Wendelhag, O. Wiklund, and J. Wikstrand Arterial wall thickness in familial hypercholesterolemia. Ultrasound measurement of intima-media thickness in the common carotid artery Arterioscler. Thromb. 12 1992 70 77
    • (1992) Arterioscler. Thromb. , vol.12 , pp. 70-77
    • Wendelhag, I.1    Wiklund, O.2    Wikstrand, J.3
  • 11
    • 79959588338 scopus 로고    scopus 로고
    • Inter-reader differences in common carotid artery intima-media thickness: Implications for cardiovascular risk assessment and vascular age determination
    • J.F. Polak, L.C. Funk, and D.H. O'Leary Inter-reader differences in common carotid artery intima-media thickness: implications for cardiovascular risk assessment and vascular age determination J. Ultrasound Med. 30 2011 915 920
    • (2011) J. Ultrasound Med. , vol.30 , pp. 915-920
    • Polak, J.F.1    Funk, L.C.2    O'Leary, D.H.3
  • 14
    • 77957890201 scopus 로고    scopus 로고
    • A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound
    • F. Molinari, G. Zeng, and J.S. Suri A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound Comput. Meth. Prog. Biomed. 100 2010 201 221
    • (2010) Comput. Meth. Prog. Biomed. , vol.100 , pp. 201-221
    • Molinari, F.1    Zeng, G.2    Suri, J.S.3
  • 15
    • 54149096512 scopus 로고    scopus 로고
    • Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator
    • F. Faita, V. Gemignani, E. Bianchini, C. Giannarelli, L. Ghiadoni, and M. Demi Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator J. Ultrasound Med. 27 2008 1353 1361
    • (2008) J. Ultrasound Med. , vol.27 , pp. 1353-1361
    • Faita, F.1    Gemignani, V.2    Bianchini, E.3    Giannarelli, C.4    Ghiadoni, L.5    Demi, M.6
  • 16
    • 0035720717 scopus 로고    scopus 로고
    • An automatic measurement system for the evaluation of carotid intima-media thickness
    • C. Liguori, A. Paolillo, and A. Pietrosanto An automatic measurement system for the evaluation of carotid intima-media thickness Instrum. Meas., IEEE Trans. 50 2001 1684 1691
    • (2001) Instrum. Meas., IEEE Trans. , vol.50 , pp. 1684-1691
    • Liguori, C.1    Paolillo, A.2    Pietrosanto, A.3
  • 17
    • 20044391595 scopus 로고    scopus 로고
    • A semiautomated ultrasound border detection program that facilitates clinical measurement of ultrasound carotid intima-media thickness
    • J.H. Stein, C.E. Korcarz, M.E. Mays, P.S. Douglas, M. Palta, and H. Zhang A semiautomated ultrasound border detection program that facilitates clinical measurement of ultrasound carotid intima-media thickness J. Am. Soc. Echocardiogr. 18 2005 244 251
    • (2005) J. Am. Soc. Echocardiogr. , vol.18 , pp. 244-251
    • Stein, J.H.1    Korcarz, C.E.2    Mays, M.E.3    Douglas, P.S.4    Palta, M.5    Zhang, H.6
  • 18
    • 54249107589 scopus 로고    scopus 로고
    • Automatic recognition of the common carotid artery in longitudinal ultrasound B-Mode scans
    • A.C. Rossi, P.J. Brands, and A.P. Hoeks Automatic recognition of the common carotid artery in longitudinal ultrasound B-Mode scans Med. Image. Anal. 12 2008 653 665
    • (2008) Med. Image. Anal. , vol.12 , pp. 653-665
    • Rossi, A.C.1    Brands, P.J.2    Hoeks, A.P.3
  • 19
    • 76749109541 scopus 로고    scopus 로고
    • Automatic localization of intimal and adventitial carotid artery layers with noninvasive ultrasound: A novel algorithm providing scan quality control
    • A.C. Rossi, P.J. Brands, and A.P. Hoeks Automatic localization of intimal and adventitial carotid artery layers with noninvasive ultrasound: a novel algorithm providing scan quality control Ultrasound Med. Biol. 36 2010 467 479
    • (2010) Ultrasound Med. Biol. , vol.36 , pp. 467-479
    • Rossi, A.C.1    Brands, P.J.2    Hoeks, A.P.3
  • 21
    • 0033624995 scopus 로고    scopus 로고
    • A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images
    • Q. Liang, I. Wendelhag, J. Wikstrand, and T. Gustavsson A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images IEEE Trans. Med. Imaging. 19 2000 127 142
    • (2000) IEEE Trans. Med. Imaging. , vol.19 , pp. 127-142
    • Liang, Q.1    Wendelhag, I.2    Wikstrand, J.3    Gustavsson, T.4
  • 22
    • 33947315277 scopus 로고    scopus 로고
    • A modular software system to assist interpretation of medical images— Application to vascular ultrasound images
    • J. Stoitsis, S. Golemati, and K.S. Nikita A modular software system to assist interpretation of medical images— application to vascular ultrasound images Instrum. Meas., IEEE Trans. 55 2006 1944 1952
    • (2006) Instrum. Meas., IEEE Trans. , vol.55 , pp. 1944-1952
    • Stoitsis, J.1    Golemati, S.2    Nikita, K.S.3
  • 25
    • 59449093925 scopus 로고    scopus 로고
    • Segmentation in ultrasonic B-Mode images of healthy carotid arteries using mixtures of Nakagami distributions and stochastic optimization
    • F. Destrempes, J. Meunier, M.F. Giroux, G. Soulez, and G. Cloutier Segmentation in ultrasonic B-Mode images of healthy carotid arteries using mixtures of Nakagami distributions and stochastic optimization IEEE Trans. Med. Imaging 28 2009 215 229
    • (2009) IEEE Trans. Med. Imaging , vol.28 , pp. 215-229
    • Destrempes, F.1    Meunier, J.2    Giroux, M.F.3    Soulez, G.4    Cloutier, G.5
  • 26
    • 36849025927 scopus 로고    scopus 로고
    • Using the Hough transform to segment ultrasound images of longitudinal and transverse sections of the carotid artery
    • S. Golemati, J. Stoitsis, E.G. Sifakis, T. Balkizas, and K.S. Nikita Using the Hough transform to segment ultrasound images of longitudinal and transverse sections of the carotid artery Ultrasound Med. Biol. 33 2007 1918 1932
    • (2007) Ultrasound Med. Biol. , vol.33 , pp. 1918-1932
    • Golemati, S.1    Stoitsis, J.2    Sifakis, E.G.3    Balkizas, T.4    Nikita, K.S.5
  • 28
    • 0036139071 scopus 로고    scopus 로고
    • Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images
    • D.C. Cheng, A. Schmidt-Trucksass, K.S. Cheng, and H. Burkhardt Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images Comput. Meth. Prog. Biomed. 67 2002 27 37
    • (2002) Comput. Meth. Prog. Biomed. , vol.67 , pp. 27-37
    • Cheng, D.C.1    Schmidt-Trucksass, A.2    Cheng, K.S.3    Burkhardt, H.4
  • 29
    • 34547924050 scopus 로고    scopus 로고
    • Characterization of a completely user-independent algorithm for carotid artery segmentation in 2-D ultrasound images
    • S. Delsanto, F. Molinari, P. Giustetto, W. Liboni, S. Badalamenti, and J.S. Suri Characterization of a completely user-independent algorithm for carotid artery segmentation in 2-D ultrasound images Instrum. Meas., IEEE Trans. 56 2007 1265 1274
    • (2007) Instrum. Meas., IEEE Trans. , vol.56 , pp. 1265-1274
    • Delsanto, S.1    Molinari, F.2    Giustetto, P.3    Liboni, W.4    Badalamenti, S.5    Suri, J.S.6
  • 31
    • 0032028944 scopus 로고    scopus 로고
    • Snakes, shapes, and gradient vector flow
    • C. Xu, and J.L. Prince Snakes, shapes, and gradient vector flow IEEE Trans. Image Process. 7 1998 359 369
    • (1998) IEEE Trans. Image Process. , vol.7 , pp. 359-369
    • Xu, C.1    Prince, J.L.2
  • 32
    • 77951925205 scopus 로고    scopus 로고
    • Intima-media thickness: Setting a standard for completely automated method for ultrasound
    • F. Molinari, G. Zeng, and J.S. Suri Intima-media thickness: setting a standard for completely automated method for ultrasound IEEE Trans. Ultrason. Ferr. Freq. Control 57 2010 1112 1124
    • (2010) IEEE Trans. Ultrason. Ferr. Freq. Control , vol.57 , pp. 1112-1124
    • Molinari, F.1    Zeng, G.2    Suri, J.S.3
  • 33
    • 76449106558 scopus 로고    scopus 로고
    • Automatic computer-based tracings (ACT) in longitudinal 2-D ultrasound images using different scanners
    • F. Molinari, W. Liboni, P. Giustetto, S. Badalamenti, and J.S. Suri Automatic computer-based tracings (ACT) in longitudinal 2-D ultrasound images using different scanners J. Mech. Med. Biol. 9 2009 481 505
    • (2009) J. Mech. Med. Biol. , vol.9 , pp. 481-505
    • Molinari, F.1    Liboni, W.2    Giustetto, P.3    Badalamenti, S.4    Suri, J.S.5
  • 34
    • 84857322542 scopus 로고    scopus 로고
    • Completely automated multi-resolution edge snapper (CAMES) inverted question mark a new technique for an accurate carotid ultrasound IMT measurement: Clinical validation and benchmarking on a multi-institutional database
    • F. Molinari, C. Pattichis, G. Zeng, L. Saba, U. Acharya, and R. Sanfilippo Completely automated multi-resolution edge snapper (CAMES) inverted question mark a new technique for an accurate carotid ultrasound IMT measurement: clinical validation and benchmarking on a multi-institutional database IEEE Trans. Image Process. 21 2012 1211 1222
    • (2012) IEEE Trans. Image Process. , vol.21 , pp. 1211-1222
    • Molinari, F.1    Pattichis, C.2    Zeng, G.3    Saba, L.4    Acharya, U.5    Sanfilippo, R.6
  • 35
    • 84855578470 scopus 로고    scopus 로고
    • Four image interpolation techniques for ultrasound breast phantom data acquired using Fischer's full field digital mammography and ultrasound system (FFDMUS): A comparative approach
    • (II 1238-41)
    • Y. Zhen, S. Jasjit, S. Yajie, R. Janer, Four image interpolation techniques for ultrasound breast phantom data acquired using Fischer's full field digital mammography and ultrasound system (FFDMUS): a comparative approach, in: Image Processing, 2005 ICIP 2005 IEEE International Conference on, vol. 2, 2005 (II-1238-41).
    • (2005) Image Processing, 2005 ICIP 2005 IEEE International Conference on , vol.2
    • Zhen, Y.1    Jasjit, S.2    Yajie, S.3    Janer, R.4
  • 37
    • 0034298613 scopus 로고    scopus 로고
    • The first absolute central moment in low-level image processing
    • M. Demi, M. Paterni, and A. Benassi The first absolute central moment in low-level image processing Comput. Vis. Image Und. 80 2000 57 87
    • (2000) Comput. Vis. Image Und. , vol.80 , pp. 57-87
    • Demi, M.1    Paterni, M.2    Benassi, A.3
  • 38
    • 0034421371 scopus 로고    scopus 로고
    • Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms
    • J.S. Suri, R.M. Haralick, and F.H. Sheehan Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms Pattern Anal. Appl. 3 2000 39 60
    • (2000) Pattern Anal. Appl. , vol.3 , pp. 39-60
    • Suri, J.S.1    Haralick, R.M.2    Sheehan, F.H.3
  • 39
    • 63149168898 scopus 로고    scopus 로고
    • Ultrasound image texture analysis of the intima and media layers of the common carotid artery and its correlation with age and gender
    • C.P. Loizou, M. Pantziaris, M.S. Pattichis, E. Kyriacou, and C.S. Pattichis Ultrasound image texture analysis of the intima and media layers of the common carotid artery and its correlation with age and gender Comput. Med. Imaging Graph. 33 2009 317 324
    • (2009) Comput. Med. Imaging Graph. , vol.33 , pp. 317-324
    • Loizou, C.P.1    Pantziaris, M.2    Pattichis, M.S.3    Kyriacou, E.4    Pattichis, C.S.5
  • 41
    • 0018306059 scopus 로고
    • A Threshold Selection Method from Gray-Level Histograms
    • N. Otsu A Threshold Selection Method from Gray-Level Histograms Syst. Man Cybern. IEEE Trans. 9 1979 62 66
    • (1979) Syst. Man Cybern. IEEE Trans. , vol.9 , pp. 62-66
    • Otsu, N.1
  • 42
    • 0026741340 scopus 로고
    • A fast algorithm for active contours and curvature estimation
    • D.J. Williams, and M. Shah A fast algorithm for active contours and curvature estimation CVGIP-Image Understan. 55 1992 14 26
    • (1992) CVGIP-Image Understan. , vol.55 , pp. 14-26
    • Williams, D.J.1    Shah, M.2
  • 43
    • 33745456397 scopus 로고    scopus 로고
    • Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filtering
    • C.P. Loizou, C.S. Pattichis, M. Pantziaris, T. Tyllis, and A. Nicolaides Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filtering Med. Biol. Eng. Comput. 44 2006 414 426
    • (2006) Med. Biol. Eng. Comput. , vol.44 , pp. 414-426
    • Loizou, C.P.1    Pattichis, C.S.2    Pantziaris, M.3    Tyllis, T.4    Nicolaides, A.5
  • 44
    • 84859961242 scopus 로고    scopus 로고
    • Comparison between manual and automated analysis for the quantification of carotid wall by using sonography. A validation study with CT
    • in press
    • L. Saba, R. Montisci, F. Molinari, N. Tallapally, G. Zeng, G. Mallarini, J.S. Suri, Comparison between manual and automated analysis for the quantification of carotid wall by using sonography. A validation study with CT, Eur. J. Radiol. (2011), in press.
    • (2011) Eur. J. Radiol
    • Saba, L.1    Montisci, R.2    Molinari, F.3    Tallapally, N.4    Zeng, G.5    Mallarini, G.6    Suri, J.S.7
  • 45
    • 74749094600 scopus 로고    scopus 로고
    • Segmentation of the carotid intima-media region in B-Mode ultrasound images
    • R. Rocha, A. Campilho, J. Silva, E. Azevedo, and R. Santos Segmentation of the carotid intima-media region in B-Mode ultrasound images Image Vis. Comput. 28 2010 614 625
    • (2010) Image Vis. Comput. , vol.28 , pp. 614-625
    • Rocha, R.1    Campilho, A.2    Silva, J.3    Azevedo, E.4    Santos, R.5
  • 47


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.