메뉴 건너뛰기




Volumn 927, Issue , 2012, Pages 603-610

The effect of screenhouse roof shape on the flow patterns - CFD simulations

Author keywords

CFD; Flow; Resistance; Screenhouse; Screens; Ventilation

Indexed keywords

HEXAPODA;

EID: 84863692944     PISSN: 05677572     EISSN: None     Source Type: Book Series    
DOI: 10.17660/ActaHortic.2012.927.74     Document Type: Conference Paper
Times cited : (15)

References (14)
  • 1
    • 0001653967 scopus 로고    scopus 로고
    • Ultra-violet absorbing screens serve as optical barriers to protect crops from virus and insect pests
    • Antigonus, Y., Lapidot, M., Hadar, D., Messika, Y. and Cohen, S. 1998. Ultra-violet absorbing screens serve as optical barriers to protect crops from virus and insect pests. Journal of Economical Entomology 91:1401-1405.
    • (1998) Journal of Economical Entomology , vol.91 , pp. 1401-1405
    • Antigonus, Y.1    Lapidot, M.2    Hadar, D.3    Messika, Y.4    Cohen, S.5
  • 2
    • 33947224800 scopus 로고    scopus 로고
    • Screens stop insects but slow airflow
    • Bailey, B.J. 2003. Screens stop insects but slow airflow. Fruit & Veg. Tech. 3:6-8.
    • (2003) Fruit & Veg. Tech. , vol.3 , pp. 6-8
    • Bailey, B.J.1
  • 3
    • 58049211833 scopus 로고    scopus 로고
    • Computational fluid dynamics (CFD) study of large scale screenhouses
    • Flores-Velazquez, J. and Montero, J.I. 2008. Computational fluid dynamics (CFD) study of large scale screenhouses. Acta Hort. 797:117-122.
    • (2008) Acta Hort. , vol.797 , pp. 117-122
    • Flores-Velazquez, J.1    Montero, J.I.2
  • 4
    • 33645883540 scopus 로고    scopus 로고
    • A wind tunnel study of airflow through horticultural crops: Determination of the drag coefficient
    • Molina-Aiz, F.D., Valera, D.L., Alvarez, A.J. and Madueno, A. 2006. A wind tunnel study of airflow through horticultural crops: Determination of the drag coefficient. Biosystems Engineering 93(4):447-457.
    • (2006) Biosystems Engineering , vol.93 , Issue.4 , pp. 447-457
    • Molina-Aiz, F.D.1    Valera, D.L.2    Alvarez, A.J.3    Madueno, A.4
  • 5
    • 33846158864 scopus 로고    scopus 로고
    • Effects of a shading screen on microclimate and crop water requirements
    • Moller, M. and Assouline, S. 2007. Effects of a shading screen on microclimate and crop water requirements. Irrig. Sci. 25:171-181.
    • (2007) Irrig. Sci. , vol.25 , pp. 171-181
    • Moller, M.1    Assouline, S.2
  • 7
    • 37849186863 scopus 로고    scopus 로고
    • Influence of changes in cover and height on the climate of canary-screenhouses for tomato growth: Preliminary results
    • Raya, V., Parra, M. and Cid, M.C. 2006. Influence of changes in cover and height on the climate of canary-screenhouses for tomato growth: preliminary results. Acta Hort. 719:535-541.
    • (2006) Acta Hort. , vol.719 , pp. 535-541
    • Raya, V.1    Parra, M.2    Cid, M.C.3
  • 8
    • 56349139711 scopus 로고    scopus 로고
    • Photo-selective netting for improved performance of horticultural crops. A review of ornamental and vegetable studies carried out in Israel
    • Shahak, Y. 2008. Photo-selective netting for improved performance of horticultural crops. A review of ornamental and vegetable studies carried out in Israel. Acta Hort. 770: 161-168.
    • (2008) Acta Hort. , vol.770 , pp. 161-168
    • Shahak, Y.1
  • 9
    • 71449108678 scopus 로고    scopus 로고
    • The effect of height on screenhouse microclimate
    • Tanny, J., Teitel, M., Barak, M., Esquira, Y. and Amir, R. 2008. The effect of height on screenhouse microclimate. Acta Hort. 801:107-114.
    • (2008) Acta Hort. , vol.801 , pp. 107-114
    • Tanny, J.1    Teitel, M.2    Barak, M.3    Esquira, Y.4    Amir, R.5
  • 10
    • 33749120308 scopus 로고    scopus 로고
    • Airflow characteristics, energy balance and eddy covariance measurements in a banana screenhouse
    • Tanny, J., Haijun, L. and Cohen, S. 2006. Airflow characteristics, energy balance and eddy covariance measurements in a banana screenhouse. Agricultural and Forest Meteorology 139:105-118.
    • (2006) Agricultural and Forest Meteorology , vol.139 , pp. 105-118
    • Tanny, J.1    Haijun, L.2    Cohen, S.3
  • 11
    • 0037336976 scopus 로고    scopus 로고
    • Screenhouse microclimate and ventilation: An experimental study
    • Tanny, J., Cohen, S. and Teitel, M. 2003. Screenhouse microclimate and ventilation: An experimental study. Biosystems Engineering 84(3):331-341.
    • (2003) Biosystems Engineering , vol.84 , Issue.3 , pp. 331-341
    • Tanny, J.1    Cohen, S.2    Teitel, M.3
  • 13
    • 75349083554 scopus 로고    scopus 로고
    • Using computational fluid dynamics simulations to determine pressure drops on woven screens
    • Teitel, M. 2010. Using computational fluid dynamics simulations to determine pressure drops on woven screens. Biosystems Engineering 105(2):172-179.
    • (2010) Biosystems Engineering , vol.105 , Issue.2 , pp. 172-179
    • Teitel, M.1
  • 14
    • 67349163242 scopus 로고    scopus 로고
    • New inflow boundary conditions for modelling the neutral equilibrium atmospheric boundary layer in computational wind engineering
    • Yang, Y., Gu, M., Chen, S. and Jin, X. 2009. New inflow boundary conditions for modelling the neutral equilibrium atmospheric boundary layer in computational wind engineering. Journal of Wind Engineering and Industrial Aerodynamics 97:88-95.
    • (2009) Journal of Wind Engineering and Industrial Aerodynamics , vol.97 , pp. 88-95
    • Yang, Y.1    Gu, M.2    Chen, S.3    Jin, X.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.